The  inputs  shown  in  the  blue  box 
connect directly to the inputs in the 
yellow box on the Metron4 above 

Run the sensor cable(s) through the 
lower unit’s glands. 

Unplug  the  green  connector(s)  and 
wire in as required. 

Plug  the  connector(s)  back  into  the 
correct input channel and tighten the 
gland.  Ensure  cable  is  through  the 
gland. 

Reattach  all  lids  and  take  care  to 
tighten screws to ensure waterproof 
IP67 rating is maintained. 

3.

 

Mount the Metron 4 

Ideally  a  flat  surface  such  as  a 
wall/ DIN railing/ Unistrut railing. 

Avoid  mounting  inside  metal 
cabinets  or  underground  (could 
reduce signal). 

There  are  pre-drilled  holes  for 
easy mounting. 

4.

 

Connect  the Battery  

2.

 

Mount the Solar Panel  

Solar  panel  comes  attached  to  a 
mounting  bracket.  The  panel  must 
face directly south and have a view of 
at least 100° of unobstructed sky. 

The panel should be tilted at an angle 
10° to 15° plus the site’s latitude from 
the  horizontal  to  achieve  maximum 
sun exposure (example overleaf). 

The higher the cell, the better. 

Ensure  the  highlighted  switch  is 
positioned at Solar. 

Remove  the  white  plastic  cover 
from the battery terminals. 

Use the loose black and red wires 
and  slide  on  to  connect  to  the 
battery terminals. 

Maintain polarity: 

 to 

 (-). 

 to 

 (+). 

 

5.

 

Connect  the Sensor(s)  

1.  Unpack & Open Up the Metron4  

Place unit on a flat surface. 
To  open,  loosen  the  2 
nylon  screws  in  the 
bottom  corners  of  the 
Metron4  and  4  screws 
around battery.  

Allen key and Pozi / Phillips 
head screwdriver required

EASY INSTALL  GUIDE : M4/SOL - SYS   

 

 

[email protected]

Tel: +44(0) 1827 310 666

EASY INSTALL GUIDE: M4/SOL-SYS

 

 

8.

 

View Data  

Press any button to wake the Metron4. Press left to cycle channels for immediate 
reading (config. dependent) or enter PIN (1234) and press right after 4

th

 digit to 

enter homepage. 

Move down to Force Transmit and right to select. Watch the progress bar and 
wait  for  the  unit  to  transmit.  Once  complete,  data  can  be  viewed  on 
MetronView. The unit will countdown for 45 seconds, then enter Run Mode. 
Screen will turn off. 

For live channel readings, channels can be selected from the menu by pressing 
right on Channels and Read Now.  

 

EASY INSTALL  GUIDE : M4/ SOL - SYS   

 

 

7.

 

Programming  

Visit: 

www.metronview.com

 

Login  credentials  will  have 
been sent by email. 

Once logged in, a summary of 

Units can be remotely programmed from MetronView. It is 
possible  to  change  how  often  units  are  taken  &  sent,  alter 
scaling and alarm thresholds for each input channel and much 
more. 