- 1 -
OPErATiOn
GB
0400-GB EINSATZ_8521
12
13
10
11
Hopper: Filling/Emptying
The seed drill should only be filled after it has been mounted and
lowered.
The seed level is shown on the indicator (front hopper wall).
Observe the swimmer when filling the seed drill (
10/1
).
Do not run the hopper „on empty“; when seed level is low, ensure
even distribution.
Emptying
Lower the combination.
Lift the emptying trays so that they unlock (at
11/1
), and place
horizontally.
Unlock the seed guide rail on both sides (
11/2
) - and lower.
Place the trays on the seed guide rail (
12/1
).
Open all shutters (
12/2
).
Open the gates as far as possible – move lever to full extent
(
13/1
).
Take note!
- Empty only small residue amounts over the drop
bottom. If drop bottom is full, danger exists of
readjustment when closing.
- Empty large residue amounts from seed tank with
suitable container (bucket).
Cleaning the Hopper:
- Blow out residue with compressed air,
- Wear protective clothing against toxic seed dressing dust!
- Leave the gates wide open,
so mice, for example, do not smell the seed and attempt to chew
through the hopper on the parked drill.