About the Boiler

This is a Floor Standing, Horizontally Fired, Automatic Pressure Jet Oil Boiler.
The boiler can be flued conventionaly or with a kit as a balanced flue.
This boiler is for use with Kerosine and for use in GB & IE.
This boiler can be converted for use with Gas Oil (CF only, not 45/50L).

About Safety

Installation must have been in accordance with the Installation & Service Instructions and the
rules in force.

Leave these instructions with the user for use on future calls.

Statesman

45/50L, 50/70L, 70/90L, 90/110L,

Utility 50/70L, 70/90L, 90/110L,

110/130L, 130/150L

Users Instructions

Summary of Contents for Statesman 45/50L

Page 1: ...ith Kerosine and for use in GB IE This boiler can be converted for use with Gas Oil CF only not 45 50L About Safety Installation must have been in accordance with the Installation Service Instructions and the rules in force Leave these instructions with the user for use on future calls Statesman 45 50L 50 70L 70 90L 90 110L Utility 50 70L 70 90L 90 110L 110 130L 130 150L Users Instructions ...

Page 2: ...ers or spillages Fuels remove natural oils and fats and may thus cause cracking and irritation of the skin Gas oil may also cause irreversible damage to your health on prolonged or repeated skin contact Precautions ALWAYS HANDLE fuels in the open air or in a well ventilated place well away from all sources of ignition such as fires sparks hot surfaces and DO NOT SMOKE ALWAYS DRAIN fuels using a pr...

Page 3: ... the oil to fall to the bottom of the tank as sludge might be sucked into the fuel pipe If possible switch off the burner before any fresh supply of oil is delivered and start it again about one hour later to give any dirt in the tank a chance to settle Air Supply Your installer will have made arrangements for an adequate supply of fresh air to the boiler to ensure safe operation Do not block any ...

Page 4: ... 180 F For milder or summer conditions it may be advisable to set the knob on or about the seventh dot from minimum Never leave the boiler thermostat at a setting between OFF and the minimum setting otherwise serious corrosion of the boiler will occur See Fig 3 Boiler Thermostat Utility The Thermostat OFF position is designated the knob must be turned clockwise to the minimum setting 1 at this pos...

Page 5: ...Part No 5105705 5 Users Instructions Fig 3 ST00268A Optional Programmer Fig 2 ...

Page 6: ...ect the electricity supply and shut off the oil supply at the storage tank To relight restore the oil supply and then the electricity supply reset the controls and timer if fitted Clearances The boiler must have the following minimum clearances for servicing Front of Boiler 610mm 24in Sides of Boiler Balanced Flue 6mm 1 4in Conventional Flue 25mm 1in Top of boiler 12mm 1 2in Frost Protection If fr...

Page 7: ...ring defect on the appliance only not the system or ancillary controls free of charge for parts and labour subject to there being no misuse or abuse Service visits by Potterton Service Operations outside the terms of the boiler guarantee will be charged for both parts and labour at normal rates for chargeable work During the period of the boiler guarantee Potterton will only be responsible for the...

Page 8: ...anges and improvements in our products which may affect the accuracy of the information contained in this leaflet All goods are sold subject to our standard Conditions of Sale which are available on request To aid continuous improvement and staff training calls to this line may be monitored or recorded General Enquiries Tel Technical Tel Service Tel Fax Literature Request Tel Publication No 510570...