Standard Horizontal Flue
Minimum dimension X including wall
thickness = 160 mm
Maximum dimension X = 700 mm
Wall seal
Silicone grease to be
applied to the single
lip inner seal
4.2
Install the Flue
These instructions are for standard horizontal
rear and side flue applications which have a
maximum horizontal installed length of 700 mm
when fitted.
The flue elbow is supplied set to the rear.
For side outlet slacken the screws and
turn the elbow to the required position
and re-tighten screws. Ensure all flue
elbow seals are still correctly located.
If using a left hand side flue application
we recommended you make the flow and
return water connections before fitting
the flue.
1. Measure dimension X from the centre point
of the flue elbow to the outside of the wall
and add 50 mm.
2. Mark the dimension to be cut onto the flue as
shown. Re-check measurements and ensure
the inner flue support bracket is pushed
beyond the cut line before cutting.
Cut outer tube and then cut the inner tube
flush with the outer. Deburr both tube ends.
3. Slide the wall seal along the flue and into
position behind the terminal.
4. To ease assembly of the flue system apply
the silicone grease (provided) to the inner
seal of the flue elbow. Pass the flue through
the wall and push firmly into the flue elbow.
The flue is correctly located when the visual
check holes are blocked.
5. Ensure the terminal shroud is vertical as
shown opposite.
6. Make good the wall around the flue.
7. Refer to Page 17 for flue deflector and or
terminal guard requirements
Fig. 34
Silicone Grease Safety Data
The grease supplied is not regarded as a health or environmental hazard under
current legislation.
First Aid Measures
Inhalation - Not relevant
Ingestion
Never make an unconscious person vomit or drink fluids ! Rinse mouth thoroughly
and drink plenty of water. Get medical attention if any discomfort continues.
Skin Contact
Remove affected person from source of contamination. Get medical attention if
irritation persists after washing.
Eye Contact
Make sure to remove any contact lenses from the eyes before rinsing. Promptly
wash eyes with plenty of water while lifting the eye lids. Continue to rinse for at
least 15 minutes. Get medical attention if any discomfort continues.