10.0 Installation
36
© Baxi Heating UK Ltd 2012
10.8
Making The Electrical Connections
WARNING: This appliance must be earthed
1. The electrical connections are on the right hand side of
the unit.
2. Undo the two screws securing the cable clamp and place
to one side (Fig. 31).
3. Route the incoming electrical cable/s through the
grommet in the support bracket. This will prevent damage
to the cable.
4. Lay the cable through the cable clamp to gauge the length
of cable required when it is connected to the 4-way
terminal block.
5. Connect the (S/L), (N) and ( ) wires to the
4-way terminal block (Fig. 33) and refit the cable clamp
(Fig. 31).
6. Check the electrical installation for:-
earth continuity, short circuits, resistance to earth, correct
polarity and fuse failure.
Fig. 33
S/L
N
Fig. 31
Cable Clamp
4-way Terminal Block
P/F
Optional Pump Feed Connection
only required for fully TRV’d system