MKT. #8870001 - REV M

MFG. #5400736 - 7/99

PAGE 1 OF 6

PRINTED IN USA

EVD-S

ELECTRONIC VIBRATION DETECTOR

SYSTEM

 EVD-C

  EVD-P

AMPLIFIER

PICKUP UNITS

UL LISTED

Dimensions:

12 1/4"H x 8 3/8"W x 3 1/8"D
31,1cm H x 21,3cm W x 7,9 cm D

Weight:  

8 lbs., 3,6 kg.

Enclosure:  

18 Gauge - Cold Rolled Steel

Power Input:

  12VAC, 20VA, 60Hz

Operating Voltage:  

6VDC

Typical Current:

  20mA

Alarm Current: 

 25mA

Contact Ratings:

Alarm Relay and Tamper Switch
1.0 Amp at 28VDC
0.1 Amp at 130VDC

Optional Equipment:

  An APC, Accumulator Pulse

Counter, is available for use in applications where
extraneous signals may cause false alarms.  Mounts in
EVD-C housing.  (See Bulletin No. 5400740.)

GENERAL INFORMATION

The EVD-S, Electronic Vibration Detector System, is listed
by Underwriters Laboratories, Inc. for primary protection of
Mercantile or Bank, safe or vault and supplementary protec-
tion of interior units such as file cabinets, display cases,
walls and ceilings. The System must be used with an
appropriate UL listed control unit.

EVD-C PROCESSOR UNIT

The amplifier unit, model EVD-C, provides SPDT alarm
contacts for connection into the alarm protective circuit.  The
EVD-C is housed in a metal cabinet protected by a cover
tamper and a housing vibration detector. The housing
detector is provided with a housing sensitivity control.

A low voltage plug-in transformer and a regulated battery
charging circuit maintain the standby battery at a fully
charged state.

An auxiliary output is provided to power the APC-B (accu-
mulator option) when required. The battery provides in
excess of 80 hours standby operation even if the maximum
6VDC auxiliary output is utilized.

The EVD-C provides an AC on indicator (green LED), a test

button, and an alarm indicator (red LED) for subscriber
testing of the EVD-S System. Terminals are also provided
for connection of a remote test unit, Model  PTU-B, and/or
connection of dry contacts from any Underwriters Laborato-
ries Listed central station test unit.

From 2 to 15 pickup units may be connected to the EVD-C in
a series supervised pickup loop. The supervision of the pickup
loop is maintained by a factory adjusted DC differential circuit,
which makes a compromise attempt of the pickup loop more
difficult.

EVD-P PICKUP UNIT

Model EVD-P pickup units detect sound vibrations in the
protected material. These signals are fed to the amplifier
unit where the pickup loop sensitivity control determines the
signal level necessary to create an alarm condition. A Model
EOLR resistor assembly must be installed in the last EVD-
P.

The pickup units are housed in a 4 1/4"H x 3"W x 1 1/4"D
metal enclosure with cover and back tampers and are to be
mounted with the speaker opening against the protected
material.

Potter Electric Signal Company

 •

 2081 Craig Road, St. Louis, MO, 63146-4161 

 Phone: 800-325-3936/Canada 888-882-1833

 

 www.pottersignal.com

Summary of Contents for EVD-S

Page 1: ...plug in transformer and a regulated battery charging circuit maintain the standby battery at a fully charged state An auxiliary output is provided to power the APC B accu mulator option when required The battery provides in excess of 80 hours standby operation even if the maximum 6VDC auxiliary output is utilized The EVD C provides an AC on indicator green LED a test button and an alarm indicator ...

Page 2: ... an off condition Never leave the unit in this unprotected condition TESTING Pressing Test button on front of EVD C induces a test signal into the EVD C amplifier An alarm condition indicated by a RedLEDadjacenttothetestbuttonmustoccur IfaModelAPC BAccumulatorhasbeeninstalled thetestbuttonmust be held in approximately 30 seconds before the unit will go into the alarm condition Operation of the sys...

Page 3: ...d 3 Remove jumper on terminals 12 and 13 if remote test unit Model PTU B is used 4 Battery Design life 4 years Mark date on battery and charge for 48 hours before putting unit into service Only Elpower Altus EP640 Power Sonic Corp PS640 or PS642 Panasonic LCR6V4P and Eagle Picher CFM6V4 6 may be used on UL Listed installations 5 Output terminals 8 and 9 for powering APC B accumulator if required T...

Page 4: ...n Power Limited See Fig 7 Suggested Wire Routing FIG 3 TYPICAL VAULT INSTALLATION PTU B must be used if EVD C is mounted inside vault EOLR resistor assembly installed in last pickup 1 Ground terminal 3 to cold water pipe and use shielded cable for pickup loop and remote test unit to reduce RFI 2 Central Station Test Dry contact closure across terminals 10 and 11 will initiate test Not applicable i...

Page 5: ...D S ELECTRONIC VIBRATION DETECTOR SYSTEM RECOMMENDED EVD P SPACING WALL CONSTRUCTION TYPE FEET POURED CONCRETE 10 PLASTERBOARD 20 CONCRETE BLOCK 20 BRICK 10 FIG 5 TYPICAL EVD P SYSTEM WIRING FOR WALL PROTECTION FIG 6 RECOMMENDED EVD P SPACING FOR CONCRETE BLOCK WALL ...

Page 6: ...are Class 2 Power Limited All field wiring connected to this panel must maintain a spacing of 1 4 between all Class 2 Power Limited conductors and Class 1 and or Non Power Limited conductors The enclosure is provided with multiple cable entry openings so that Class 2 Power Limited conductors can be segregated from Class 1 and or Non Power Limited conductors NOTE If Class2Power Limited conductorsar...