ORDERING INFORMATION

STOCK NO.

MODEL NO.

ADJUSTABLE

OPERATING

RANGE

MINIMUM

DEADBAND

PROOF

PRESSURE

PRESSURE

CONNECTION

DIAPHRAGM

1370010

ADPS-300-1B

25-300 PSIG

12 PSIG

400 PSIG

1/4” NPT

BRASS

BERYLLIUM COPPER

1370020

ADPS-300-1S

25-300 PSIG

12 PSIG

400 PSIG

1/4” NPT

316 S.S.

BERYLLIUM COPPER

W/316 S.S. ISOLATOR

1370030

ADPS-300-2S

25-300 PSIG

12 PSIG

400 PSIG

3/8” NPT

316 S.S.

BERYLLIUM COPPER

W/316 S.S. ISOLATOR

1370040

ADPS-600-1B

50-600 PSIG

25 PSIG

650 PSIG

1/4” NPT

BRASS

BERYLLIUM COPPER

1370050

ADPS-600-1S

50-600 PSIG

25 PSIG

650 PSIG

1/4” NPT

316 S.S.

BERYLLIUM COPPER

W/316 S.S. ISOLATOR

1370060

ADPS-600-2S

50-600 PSIG

25 PSIG

650 PSIG

3/8” NPT

316 S.S.

BERYLLIUM COPPER

W/316 S.S. ISOLATOR

Summary of Contents for ADPS Series

Page 1: ...e entire operating range of the switch The mini mum deadband minimum span between set and reset points may be obtained at any point in the operating range of the switch A change in pressure greater than the high setting will reposition the switch mechanism to open or close a single snap action electrical switch This control device is designed for use as an operating control in applications sensing...

Page 2: ...ousing into the fitting FIG 1 WIRING Use properly rated temperature supply wire for the anticipated service temperature Make all electrical connections in accordance with the National Electrical Code and local regulations A wiring check may be performed by manually actuating the switch actuator on the side of the snap actionswitchinsidetheenclosure SeeFig 3 NOTE Donotloosenorremovethetwo 2 screws ...

Page 3: ...ure en countered in the application The minimum deadband minimum span be tween set and reset points may be obtained at any point in the operating range of the switch When the desired settings are obtained re place the adjustment cover The adjustment cover and enclosure cover can be made tamper resistant by a single sealing wire inserted through the hole in the locking bar The repeatability of the ...

Page 4: ... COPPER 1370020 ADPS 300 1S 25 300 PSIG 12 PSIG 400 PSIG 1 4 NPT 316 S S BERYLLIUM COPPER W 316 S S ISOLATOR 1370030 ADPS 300 2S 25 300 PSIG 12 PSIG 400 PSIG 3 8 NPT 316 S S BERYLLIUM COPPER W 316 S S ISOLATOR 1370040 ADPS 600 1B 50 600 PSIG 25 PSIG 650 PSIG 1 4 NPT BRASS BERYLLIUM COPPER 1370050 ADPS 600 1S 50 600 PSIG 25 PSIG 650 PSIG 1 4 NPT 316 S S BERYLLIUM COPPER W 316 S S ISOLATOR 1370060 A...

Reviews: