WARNING 

This equipment has been tested and found to comply with the limits for a Class A 
digital device, pursuant to Part 15 of FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try correcting the 
interference by one or more of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 

 

If applicable, as below 
 
FCC Caution: To assure continued compliance, (example – use only shielded 
interface cables when connecting to computer or peripheral devices). Any changes 
or modifications not expressly approved by the party responsible for compliance 
could void the user’s authority to operate this equipment. 
This transmitter must not be co-located or operating in conjunction with any other 
antenna or transmitter. 
 
FCC Radiation Exposure Statement  
This equipment complies with FCC radiation exposure limits set forth for an 
uncontrolled environment. This equipment should be installed and operated with 
minimum distance 20 cm between the radiator & your body. 
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: (1) This device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that 
may cause undesired operation. 

Summary of Contents for xi3000

Page 1: ...and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help If applicable as...

Page 2: ...uffer Setting 13 4 4 2 Memory Mode 13 4 4 3 Clear Data 13 4 4 4 Send Data 13 4 4 5 Memory Data Delay 13 5 BLUETOOTH SERIAL PORT 14 5 1 CONFIGURING Xi3000 BT 14 5 1 1 Activate Bluetooth Serial Port Int...

Page 3: ...OF FIELDS 38 9 5 DIVIDING DATA INTO FIELDS 38 9 6 ADDITIONAL FIELDS 39 9 7 FIELD TRANSMISSION SEQUENCE 39 9 8 END OF FORMAT PROGRAMMING 39 9 9 ACTIVATE DATA EDITING FORMATS 39 9 10 EXCLUSIVE DATA EDI...

Page 4: ...on Bluetooth HID Supported The scanner can transmit scanned data to Bluetooth enabled computer PDA via standard HID communication Programmable Code ID Code ID can be individually configured for each s...

Page 5: ...TION barcode label the scanner will beep once then scan the SERIAL number barcode The scanner will beep twice low then high beep When it establishes RF connection with the base the scanner will then e...

Page 6: ...eep The scanner will issue a long beep with a low tone to indicate errors Enter Exit Configuration Beep The scanner will issue 6 beeps upon entering exiting the configuration mode Setup Beep In config...

Page 7: ...code is brought within Range of the scanner This will activate the LEDs and the scanner will start decoding the barcode The auto sense mode works only under Auto Off mode or Laser mode only 8 3 5 Re r...

Page 8: ...below PCAT US French German Italian Swedish Norwegian UK Belgium Spanish and Portuguese KBD PS2 30 IBM 3477 TYPE Japanese KBD IBM 34XX 319X Memorex Telex 122Keys 4 1 2 Keyboard Style Alphabets Keyboar...

Page 9: ...232 Interface User can select the desired flow control baud rate parity and data bits to be used in this output interface 4 2 1 Baud Rate Parity Data Bits The supported baud rate parity and data bit a...

Page 10: ...ction illustrates a step by step installation and configuration procedures of the Xi3000 BT for Bluetooth Serial Port Bluetooth transceivers dongles always come with their own driver or Windows XP wit...

Page 11: ...the connection is closed when the host application closes the COM port After the connection is closed the scanner will again wait for new connection request for one minute before it goes to power dow...

Page 12: ...y Computer 2 Double click the My Bluetooth Places at left Folders window Right click My Device and select Property 18 3 Select Client Applications tab and select Bluetooth Serial Port from the list th...

Page 13: ...Connection is enabled another window might pop up and asking for PIN code 8 Click OK button After successful connection the Bluetooth Device Driver will report the COM port number which is mapped for...

Page 14: ...eral Bluetooth device drivers for Windows and WinCE Pocket PC from different companies Here we use Window XP with service pack2 build in Bluetooth driver and WIDCOMM driver as examples For detail inst...

Page 15: ...canner will make necessary adjustment when sending the A Q W Z Y and M character according to this setting 6 2 3 Keyboard Style Digits There are two digit layout styles as shown on the following figur...

Page 16: ...ections 6 3 1 Windows XP with Service Pack2 1 Insert the Bluetooth dongle into PC host 2 Double click the Bluetooth icon on the lower right of the taskbar 3 Click Add button 4 Check My device is set u...

Page 17: ...mm Bluetooth Driver 1 Click icon at PC 2 Click Find Bluetooth Devices icon at My Bluetooth Places 28 3 Right click the Xi3000 BT scanner and select Pair Device 4 Input PIN code and click OK button 5 R...

Page 18: ...g transmitted 7 2 Italy French Pharmacode For Italy French Pharmacode there is always a checksum character included in the barcode So the checksum verification is always performed when decoding these...

Page 19: ...ng Because of the way system number 1 is encoded if both system numbers are enabled user might suffer from short scanning UPCA or EAN13 into UPCE system number 1 barcodes Convert to UPCA If this param...

Page 20: ...selected the max length and the min length must be specified and the scanner will only accept those codes with lengths fall between max min length specified 7 10 Plessey Convert to UK Plessey If this...

Page 21: ...ngth Code or any Additional Field and is performed before editing mode processing If only the character to be replaced is specified every occurrence of that character in the barcode will be taken away...

Page 22: ...not be performed unless all three applicable conditions are met The configurable applicable conditions are described below Code Type This parameter specifies the code type of the data eligible for dat...

Page 23: ...n the Editing Format Parameters section of the configuration manual 9 9 Activate Data Editing Formats Before data can be processed by a particular editing format that format must be enabled The editin...

Page 24: ...r most of the parameters only one read is required to set them to new values The scanner will respond with two beeps when these parameters are configured But for some special parameters multiple reads...

Page 25: ...are the scan code value of the character being programmed Add Shift The Shift key will be sent together with the character programmed 44 Add Control L The left Control key will be sent together with t...

Reviews: