BRX-VDSL2-8 (8 pairs)
Summary Diagram of Typical Installation
DSLAM
BRX-VDSL2-8
2-4 kft / 0.6-1.27 km from DSLAM (for 24 AWG / 0.51 mm equivalent gauge copper)
L1
Distance from DSLAM
L2
Distance to furthest CPE
Connecting the BRX-VDSL2-8
8 pairs from the CO
8 pairs to the
subscriber (CPE)
Shielded gel-filled
24 AWG / 0.51mm cable
IMPORTANT NOTE: The BRX-VDSL2-8 unit is powered from the Sealing Current found on a standard POTS pair.
The BRX-VDSL2-8 will not work on a dry pair (line with no sealing current). Each pair of the BRX-VDSL2-8 is powered
independently with each pair requiring the presence of the sealing DC Voltage for proper operation.
You can also use the BRX Power Injector when deploying the BRX-VDSL2-8 on dry pairs (no POTS service).
Grounding Lug
Step 1:
Select the location where the BRX-VDSL2-8 will be
inserted using the BRX-VDSL2 Calculator for the
longest
loop.
Step 2:
Connect the grounding lug of the unit to a proper ground
(usually available near the splice point).
Step 3:
Insert a BRX-BYPASS-TEST module in slot 1 and ensure
that both switches are in BYPASS mode.
Step 4:
Connect the first two (2) pairs to be amplified to the
first two (2) pairs of the BRX-VDSL2-8. Make sure to match the
DSLAM pair number to the CPE pair number.
Step 5:
Test for continuity between the DSLAM pair and CPE
pair at the splice point. If the circuits are active, the LEDs on the
BRX-BYPASS-TEST module will be ON to confirm that the sealing
current is present on both lines. If either circuit is not active, the
continuity testing will confirm that the connections are reliable.
Step 6:
Replace the BRX-BYPASS-TEST module with a
BRX-VDSL2-M module.
Step 7:
The DSLAM and CPE will now retrain the circuit and bring
up the ADSL2+ / ADSL link with the amplified bandwidth. Note
that the performance may be limited (or capped) by a setting in
the DSLAM configuration.
Step 8:
Repeat
steps 3 to 7
for the other three (3) slots of the
BRX-VDSL2-8 enclosure.
Document 180-0172-001 R02
Slot
#
Channel
#
Line
#
Cable Pair
Colors
1
1
1
White / Blue
2
2
White / Orange
2
1
3
White / Green
2
4
White / Brown
3
1
5
Red / Blue
2
6
Red / Orange
4
1
7
Red / Green
2
8
Red / Brown
Mounting flange on both ends
of the sealed unit