BRX-VDSL2-8 (8 pairs)

Summary Diagram of Typical Installation

DSLAM

BRX-VDSL2-8

2-4 kft / 0.6-1.27 km from DSLAM (for 24 AWG / 0.51 mm equivalent gauge copper)

L1

Distance from DSLAM

L2

Distance to furthest CPE

Connecting the BRX-VDSL2-8

8 pairs from the CO

8 pairs to the 
subscriber (CPE)

Shielded gel-filled  
24 AWG / 0.51mm cable

IMPORTANT NOTE: The BRX-VDSL2-8 unit is powered from the Sealing Current found on a standard POTS pair.  

The BRX-VDSL2-8 will not work on a dry pair (line with no sealing current). Each pair of the BRX-VDSL2-8 is powered  

independently with each pair requiring the presence of the sealing DC Voltage for proper operation.  

You can also use the BRX Power Injector when deploying the BRX-VDSL2-8 on dry pairs (no POTS service).

Grounding Lug

Step 1:

 Select the location where the BRX-VDSL2-8 will be 

inserted using the BRX-VDSL2 Calculator for the 

longest

 loop.

Step 2:

 Connect the grounding lug of the unit to a proper ground 

(usually available near the splice point).

Step 3:

 Insert a BRX-BYPASS-TEST module in slot 1 and ensure 

that both switches are in BYPASS mode.

Step 4:

 Connect the first two (2) pairs to be amplified to the 

first two (2) pairs of the BRX-VDSL2-8. Make sure to match the 
DSLAM pair number to the CPE pair number.

Step 5: 

Test for continuity between the DSLAM pair and CPE 

pair at the splice point. If the circuits are active, the LEDs on the 
BRX-BYPASS-TEST module will be ON to confirm that the sealing 
current is present on both lines. If either circuit is not active, the 
continuity testing will confirm that the connections are reliable.

Step 6:

 Replace the BRX-BYPASS-TEST module with a  

BRX-VDSL2-M module.

Step 7: 

The DSLAM and CPE will now retrain the circuit and bring 

up the ADSL2+ / ADSL link with the amplified bandwidth. Note 
that the performance may be limited (or capped) by a setting in 
the DSLAM configuration.

Step 8:

 Repeat 

steps 3 to 7

 for the other three (3) slots of the 

BRX-VDSL2-8 enclosure.

Document 180-0172-001 R02

Slot 

#

Channel 

#

Line 

#

Cable Pair 

Colors

1

1

1

White / Blue

2

2

White / Orange

2

1

3

White / Green

2

4

White / Brown

3

1

5

Red / Blue

2

6

Red / Orange

4

1

7

Red / Green

2

8

Red / Brown

Mounting flange on both ends 