FOR OPOS APPLICATION: 

Find the subfolder \Drivers\UPOS\OPOS of the Posiflex Product Information 
CD or DVD or download it from web site: 
http://www.posiflex.com.tw/Download%20list.asp?Status=1&Series_Name=U
POS&Model_Name=OPOS and execute the file “SETUP.EXE” to install the 
OPOS Control Manager. To add the customer display under OPOS control 
please set in OPOS Control Manager device name “PD3x-Line Display” in the 
top row. For RS-232 models, select the COM port in the 3

rd

 row and set baud 

rate to “9600” in 4

th

 row as illustrated. 

 

APPLICABLE COMMANDS 

(FOR PD-340R/350R) 

For PD-340R/350R, it is always the Epson command mode at power on. It can 
enter or exit the PST command mode through software command. 

EPSON COMMAND MODE (POWER ON DEFAULT):

 

NAME HEX 

CODES FUNCTION 

BS <08> 

Move 

Cursor 

Left 

HT <09> 

Move 

Cursor 

Right 

LF <0A> 

Move 

Cursor 

Down 

HOM 

<0B> 

Move Cursor To Home Position 

CLR 

<0C> 

Clear Display Screen 

CR 

<0D> 

Move Cursor To Left Most Position 

CAN 

<18> 

Clear Cursor Line 

ESC = 

<1B><3D><n>

Select Peripheral Device / Command Mode
n=1 pass through (should not be used) 
n=2, 3 (not required) 
n=4 switch to PST command mode 

ESC @ <1B><40>

Initialize 

Display

 

Summary of Contents for PD-350R

Page 1: ...50R Customer Display User Manual Package Contents PD 340R 350R User Manual x1 Views of the PD 340R Front View Rear View Views of the PD 350R Front View Rear View 19430907010 Ver Original http www posiflex com 1 ...

Page 2: ...to the following steps 1 Hold the PD unit and then turn the screen facing toward you 2 Locate the 4 mounting holes on the rear panel of HS series system 3 Please align the 4 PD bracket holes with the 4 screw mounting holes on the back cover of HS main unit and fasten them to mount the PD onto the back of HS main unit 4 Connect RS 232 end of the PD cable to the RS 232 port on the main unit 2 ...

Page 3: ...ps 1 Hold the PD unit and then turn the screen facing toward you 2 Locate 2 upper holes of 4 mounting holes on the rear panel of the XT series system 3 Please align the 2 PD bracket holes with the 2 screw mounting holes on the back cover of XT main unit and fasten them to mount the PD onto the back of XT main unit 4 Connect RS 232 end of the PD cable to the RS 232 port on the main unit 3 ...

Page 4: ...the 3rd row and set baud rate to 9600 in 4th row as illustrated APPLICABLE COMMANDS FOR PD 340R 350R For PD 340R 350R it is always the Epson command mode at power on It can enter or exit the PST command mode through software command EPSON COMMAND MODE POWER ON DEFAULT NAME HEX CODES FUNCTION BS 08 Move Cursor Left HT 09 Move Cursor Right LF 0A Move Cursor Down HOM 0B Move Cursor To Home Position C...

Page 5: ... Cursor On Off n 1 0 US E 1F 45 n Blink Display Screen n 0 255 PST COMMAND MODE HEX CODES FUNCTION 01 Set Pass Through Flag should not be used 06 N1 N2 Change Leading Code 14 01 Wraparound Mode Default 14 02 Vertical Scroll Mode 14 03 Insert Mode 14 04 Overwrite Mode Default 14 08 Back Space 14 09 Move Cursor Right 14 0A Move Cursor Down 14 0B Move Cursor Left 14 0C Delete Character 14 0D Move Cur...

Page 6: ... 14 1B Move Cursor To Rightmost Position Of Line 1 14 1C Move Cursor To Rightmost Position Of Line 2 The Euro Dollar Sign is designated at code D5 h To get the detailed information on PD 340R 350R please check this model from Posiflex Global Website http www posiflex com en global Download download ...

Reviews: