background image

 

 

Part 12

OPERATING SYSTEM RECOVERY 

For KS systems with operating system in the Compact Flash Card, 

once the Compact Flash is damaged for any reason, the thin client may fail to 
boot. 

A bootable new Compact Flash Card will be required to have the 

workstation back to work

. Please follow instructions given by the System 

Integrator to deal with situations like that. One more advice for CF Card 
application is that in spite of the fact that it is used in the way like an ordinary 
HDD, usual utilities such as 

FDISK.EXE or FORMAT.COM shall never be 

used on CF Card

 otherwise the boot sector of operating system itself may be 

damaged and causing the CF Card no longer bootable. 

For KS systems preloaded with Windows XP Pro or WEPOS on HDD, 

Posiflex provides recovery CD delivered with the touch terminal for the 
preloaded operating system. The System Integrator shall take care of software 
restoration after OS recovered. A Posiflex supplied USB interface CDROM 
drive will be required for such action. Other brand CDROM drive may require 
its specific driver different from what supported in the recovery CD. 

Please use the recovery CD in rescue operation only. Using it 

otherwise may wipe out whatever stored in the HDD!

 All upgrade devices 

drivers needed for manual installation in usual way are available in the 
subfolder “\drivers” in OS recove red HDD and the latest versions of these 
required drivers will be available on our web:  http://www.posiflex.com.tw. 
Then follow instructions from your system integrator for software recovery. 

OPERATING SYSTEM INSTALLATION 

This product is a highly professionalized equipment. The installation 

of an OS into a machine without any preloaded OS could constitute major 
difficulty for average user or obstacle by possibly unintentional negligence 
even for PC veterans to accomplish such a task. Therefore, OS installation into 
a system without preloaded OS is highly discouraged. Posiflex shall not be 
responsible for any technical support to questions arisen due to non-preloaded 
OS. 

Summary of Contents for KS-6115

Page 1: ... of data or profits resulting from the furnishing performance or use of this material This information is provided as is and Posiflex Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hard...

Page 2: ...ed batteries and always replace only with battery of same type DAILY MAINTENANCE GUIDE For regular cleaning of the KS systems please use only soft haired brush or dry soft cloth You may use moist soft cloth to remove stains when necessary Apply only proper amount of mild neutral detergent for obstinate stains Please note that never use Acryl dissolving solvent or Polycarbonate dissolving solvent Y...

Page 3: ...ear View Bottom View PARTS IDENTIFICATION 1 Main unit 2 Touch panel LCD panel 3 Optional side mount kit e g SD 400 4 Power indicator 5 Slim base stand 6 Cable cover 7 Removal hollow in cable cover 5 3 4 1 1 4 6 7 2 2 14 1 11 13 9 12 8 5 10 1 16 6 17 8 16 18 15 19 ...

Page 4: ... mount application and easy wall mount conversion storage room for 3 5 HDD and optional UPS battery for both desktop and wall mount applications e Support WinCE Win XP Pro WEPOS and Linux environment f High quality 15 TFT active matrix LCD panel g Brightness control by hardware h Vertical type LCD panel with easy tilt angle adjustment from 15 to 75 i Durable resistive type leading edge Infra Red t...

Page 5: ... power off protection The power switch is safely located inside a push open cover s Preconditioned power up function by alarm clock or COM port MODEM ring or LAN Option Items Note The underlined items in the following list means that option must be set prior to shipment from the factory The rest items can be set by the dealers a DDR SDRAM memory expansion up to 1GB b Integrated side mount upgrade ...

Page 6: ...essible then Please first note orientations of every existing cable connection and then disconnect every cable properly before separating the main unit from the adjustable stand assembly Please note that the click lock spring has to be pressed down prior to pulling out the connector such as the LAN port Please also note that the fixing screws have to be loosened free prior to disconnection such as...

Page 7: ...s in left picture below for slim base to open The inside will look like the right picture below with each numbered items described further below However there could be some variation to the contents inside depending on what option items actually installed 1 Cable Exit For External Connections 2 Base Box Screw 3 Cable tie Step A Prepare a soft clean flatsurface such as a piece of cloth on the desk ...

Page 8: ...is terminal according to the wall material Drywall concrete solid wood etc Consult with your contractor if it is necessary A fully equipped system may weigh up to 8 kg or 18 lbs Take the separated bottom plate and remove the 4 rubber feet to work as the wall mount bracket Fix this bracket to wall at the 3 arrowed holes for slim base model as in the above left picture with proper materials and prop...

Page 9: ...of such kind of restrictions must be taken before decision to install a base mount upgrade kit To remove the rear connect cover in slim base please refer to the inside view of the base unit at right and use a flat head screwdriver to pick the plastic hook plate of the rear connect cover from inside behind the area with Velcro strap 12 2nd LCD Panel Or Customer Display Fit the joint base of PD 2501...

Page 10: ... to find several jumpers The jumpers in this window are designated for VGA port and COM port power supply function Please consult your dealer for technical support on setup of these jumpers Please note that only those qualified technicians may adjust in the service window with information from Posiflex and the contents in the service window may change without notice as time develops SIDE MOUNT UPG...

Page 11: ...e the main unit with stand assembly for operation please connect all required cables to the appropriate connectors Please make sure that each connector is connected to the correct port with the correct orientation Damages due to incorrect connection or orientation are not covered by product warranty Some connectors like the LAN connector have to be gently inserted until a click is heard It is reco...

Page 12: ... recovered A Posiflex supplied USB interface CDROM drive will be required for such action Other brand CDROM drive may require its specific driver different from what supported in the recovery CD Please use the recovery CD in rescue operation only Using it otherwise may wipe out whatever stored in the HDD All upgrade devices drivers needed for manual installation in usual way are available in the s...

Page 13: ... supply for proper operation The power cable the power outlet and any power fusing arrangements must conform to local safety regulations Please never do any connection disconnection when system is still powered on Please always keep the external power adaptor in a free air circulation POWER ON OFF Touch Open Cover A gentle tap on the touch open cover at left side of the main unit will open the cov...

Page 14: ...ons such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up To utilize Modem Ring Up or Alarm Clock Wake Up function the user should enter the CMOS setup by pressing Del key at system boot up choose for PM Wake Up Events in Power Management Setup and make the Ring Power Up Control enabled for Modem Ring Up or select the Power Up by Alarm for Alarm Clock Wake Up Save the configuration and exit...

Page 15: ...CUSTOMER DISPLAY Please follow the instructions on the manual that comes along with the customer display PD 2501 or PD 2602 when it is installed SERIAL PORTS COM1 2 In KS system there are 2 serial ports available Both serial ports can supply a 5 V DC through pin 9 after proper jumper setting change Both ports are standard RS232 serial ports as status at delivery For models using RS232 interface to...

Page 16: ...icking on the right button of a mouse touching any point on the screen surface after touching the right click sticky button results as a click on the right button of the mouse at that point Posiflex USB Touch Manager A program named Posiflex USB Touch Manager and a right click sticky button tool in the program group Posiflex USB Touch Tools is installed in the preloaded Windows system with a USB i...

Page 17: ...al Manager and a right click sticky button tool in the program group Posiflex Tools is installed in the preloaded Windows system with a PS 2 interface touch panel controller This program can also be obtained by download from the POSIFLEX web site ...

Page 18: ...Part 18 ...

Page 19: ...Part 19 ...

Page 20: ...Part 20 警告使用者 這是甲類的資訊產品 在居住的環 境中使用時 可能會造成射頻干 擾 在這種情況下 使用者會被要 求採取某些適當的對策 T31454 ...