TP-5815 Pro series Technical Manual 6 - 6
SOFTWARE AWARENESS OF UPS STATUS
STATUS OF JP13 ON SOLDER SIDE COM1 PIN1 SIGNAL
1 – 2 short
Normal (DCD signal)
2 – 3 short
Detect UPS status
The UPS status is used to inform the software the power source the system is
operating on (AC adaptor or UPS battery). The default of this jumper is set to detect
the UPS status to enable the software detection on existence of AC power. When the
DCD bit of COM1 is set, the AC power is present. The user has to change this jumper
if he/she wants to detect the standard DCD signal on COM1.
AUDIO OUTPUT CONTROL
STATUS OF JP5, JP6, JP7
AUDIO OUTPUT PORT
JP5 1 – 2, JP6 1 – 2, JP7 1 – 2 Short
Stereo Line Out
JP5-2 <–> JP6-2, JP5-2 <–> JP6-2, JP7 2 – 3 Short
Mono Amplifier Out
TOUCH SIGNAL SETTING
STATUS OF JP2
TOUCH SIGNAL
1 – 3, 2 – 4 Short
COM2 Port
3 – 5, 4 – 6 Short
USB
PS/2 MOUSE SIGNAL LOOPBACK
STATUS OF JP3
PS/2 MOUSE SIGNAL
All Open
Through Riser Card
1 – 2, 3 – 4 short
Direct Loopback
INTERNAL IDE MASTER/SLAVE SELECT
STATUS OF JP15
STATUS IN IDE CHANNEL
All Open
Master
1 - 2 Short
Slave
«
«
«
«
«