background image

21 

 

 

2.11.6  Time out Between Characters 

<0 ms> 

 

5 ms 

10 ms 

 

25 ms 

 

50ms 

 

100ms 

 

Summary of Contents for CD-4860

Page 1: ...f the device at any time without preceding or direct announcement to the client Posiflex Technology Inc reserves the right to revise this manual and to make changes in the contents without obligation...

Page 2: ...splay This advanced mechanical design truly creates a win win solution for both POS retail systems and consumers In short CD 4860 is absolutely a high performance gun type scanner which provides the c...

Page 3: ...don t use this equipment for long time please cut off the power to avoid damage from surge power 10 Don t spray any liquid on this scanner because it may cause a fire or short circuit 11 Please do not...

Page 4: ...user friendly It can be connected to your POS or Host system through a RS232 cable KBW cable USB cable To read a bar code you simply press the red trigger button and aim the beam to the bar code But y...

Page 5: ...CD 4860 Area Imager Handheld Bar code Scanner b Communication Cable RS 232 or Keyboard wedge or USB c Power adaptor optional d User Manual e Transparent Cover Plate 4 Visually inspect the CD 4860 and...

Page 6: ...r supply used RS232 interface to Power cable jack 4 Plug the power supply into the AC outlet 1 6 USB INTERFACE As like all USB devices before connecting the CD 4860 with USB interface to your host sys...

Page 7: ...up the scanner b Change scanner settings by scanning any of the programming code that meet applications At any moment you can stop your programming and if needed read programming code factory default...

Page 8: ...er to Factory Default Reset all configuration parameters to their factory default setting of the Scanner and Cradle After this reset you must select all required parameters that meet applications 2 2...

Page 9: ...Port Mode 2 4 SCANNING TRIGGERING Level A reading session begins lighting and decode processing on when beam is activated and stops when beam is deactivated Continuous Scanning When the scanner is tu...

Page 10: ...nd decoding automatically turn on and stay on until another period of inactivity timeout after the timeout the scanner starts flashing again Autostand This mode allows you to switch from Flashing trig...

Page 11: ...ion lighting and decoding off Presentation This mode allows power up lighting and decoding are on After a period of inactivity lasting the time specified by the trigger timeout the lighting turns off...

Page 12: ...es Linear mode for decode 1D Barcodes Area mode allows you to set the position of the CD 4860 in any direction regardless of the orientation of the barcode and perform a good read on 1D and 2D barcode...

Page 13: ...tive the scan engine stops the reading session after a successful decoding NOTE this parameter is NOT used with continuous and continuous flashing modes Active Not Active 2 8 BUZZER BEEP TONE 2 8 1 Be...

Page 14: ...14 2 8 2 Good Read Beeps One Beep Two Beeps None 2 8 3 Beep Duration 60 msec 80 msec 200 msec Off...

Page 15: ...15 2 8 4 Timing During Transmission Before Transmission After Transmission 2 9 GOOD READ DURATION 2 9 1 Good Read LED Duration 80 msec 0 5 sec 1 sec Off...

Page 16: ...16 2 9 2 Error Beep On Off 2 9 3 Setup Beep On Off...

Page 17: ...17 2 10 RS 232 MODE PARAMETERS 2 10 1 Baud rate 1200 2400 4800 9600 19200 38400 2 10 2 Data bits Data bits 7 Data bits 8...

Page 18: ...18 2 10 3 Stop bits Stop bits 1 Stop bits 2 2 10 4 Parity None Even Odd 2 10 5 Handshaking RTS CTS Enable RTS CTS disable ACK NAK Enable...

Page 19: ...19 ACK NAK Disable XON XOFF Enable XON XOFF Disable 2 11 KEYBOARD WEDGE MODE PARAMETER 2 11 1 Terminal Type IBM PC AT PS 2 IBM PC XT IBM PS 2 25 30 2 11 2 Capslock Detection Enable Disable...

Page 20: ...20 2 11 3 Upper Lower Case No change Upper Case Lower Case 2 11 4 Send Character by ALT Method Enable Disable 2 11 5 Select Numerical Pad ON OFF...

Page 21: ...21 2 11 6 Time out Between Characters 0 ms 5 ms 10 ms 25 ms 50ms 100ms...

Page 22: ...22 2 11 7 Language Selection US English UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese...

Page 23: ...23 Belgium Portuguese Denmark Netherlands Turkey Reserved 1...

Page 24: ...24 2 12 SYMBOLOGIES SELECTION Australian Post ON Australian Post OFF AZTEC ON AZTEC OFF BPO ON BPO OFF Canada Post ON Canada Post OFF CODABAR ON...

Page 25: ...25 CODABAR OFF Codablock A ON Codablock A OFF Codablock F ON Codablock F OFF CODE 11 ON CODE 11 OFF CODE 39 ON CODE 39 OFF CODE 93 ON...

Page 26: ...26 CODE 93 OFF CODE 128 ON CODE 128 OFF GS1 128 ON GS1 128 OFF DATAMATRIX ON DATAMATRIX OFF DataMatrix Mirrored labels activation On DataMatrix Mirrored labels activation off...

Page 27: ...27 Dutch Post ON Dutch Post OFF EAN 8 ON EAN 8 OFF EAN 13 ON EAN 13 OFF EAN 128 ON EAN 128 OFF GS1 CC A B ON...

Page 28: ...28 GS1 CC A B OFF GS1 CC C ON GS1 CC C OFF GS1 DataBar Omni ON GS1 DataBar Omni OFF GS1 DataBar Limited ON GS1 DataBar Limited OFF GS1 DataBar Expand ON GS1 DataBar Expand OFF...

Page 29: ...29 Infomail ON Infomail OFF Interleave 2 of 5 ON Interleave 2 of 5 OFF Japan Post ON Japan Post OFF Matrix 2 of 5 ON Matrix 2 of 5 OFF...

Page 30: ...30 MaxiCode ON MaxiCode OFF MicroPDF417 ON MicroPDF417 OFF MSI ON MSI OFF PDF417 ON PDF417 OFF Planet ON...

Page 31: ...31 Planet OFF PLESSEY ON PLESSEY OFF Postnet ON Postnet OFF QR Code ON QR Code OFF Standard 2 of 5 ON Standard 2 of 5 OFF...

Page 32: ...32 Sweden Post ON Sweden Post OFF Telepen ON Telepen OFF TLC 39 ON TLC 39 OFF UPC A ON UPC A OFF UPC E ON UPC E OFF...

Page 33: ...l Support department or use CD 4860 utility tool 2 13 MULTI CODE The multicode function is used configure the scanner to read a series of bar codes and then transmit them all at once Follow these step...

Page 34: ...r codes compose 5 Number of bar codes compose 6 2 14 POSTAMBLES The scanner can be programmed to output Barcode data according to the following format BAR CODE DATA POSTAMBLE STRING Postamble None CR...

Page 35: ...35 Appendixes A DECIMAL VALUE TABLE 0 20 1 20 2 20 3 4 20 5 20 6 20 7 8 20 9 20...

Page 36: ...36 B ASCII TABLE A 20 B C 20 D 20 E 20 F 20 G 20 H 20 I J 20 K 20 L 20 M N 20 O 20 P 20 Q 20 R 20 S 20 T 20 U 2 V 20 W 20 X 2 Y 20 Z 20...

Page 37: ...On EAN 128 UCC On GS1 DataBar RSS Off Omni Expanded limited Interleaved 2 of 5 Off Industrial Off ISBN Off ISSN Off Matrix Off MSI Code Off Plessey Off Postal codes Off Standard 2 of 5 Off Telepen Off...

Page 38: ...80 Vertical pixels 256 gray levels Scan angle 38 Horizontal 25 Vertical Interface RS 232 USB and Bluetooth Indicators led Green good read Electrical Characteristics Operation Voltage 5 VDC 5 Current O...

Page 39: ...39 E SCAN MAP Typical Reading Distances CD 4860 Typical Reading Distance These distances are measured in an office environment 250 lux...

Page 40: ...381 mm 4 cm 37 cm Minimum distance depends on symbology length and scan angle CD 4860 Typical Reading Distances inches Symbology Density Minimum Maximum Distance Distance Code 39 5 mils 2 8 Inch 5 1 I...

Reviews: