background image

JETSTREAM

USER MANUAL

13

Assembly

•  The first stage on a Jetstream Classic 

has four (4) low pressure ports and two 
(2) high pressure ports. These different 
types of ports are marked with R/LP for 
the low pressure ports and HP for the 
high pressure ports. The port marked 
with R has a slightly higher flow rate 
then the other low pressure ports and 
this is the port where you preferably 
mount your primary second stage.

•  The first stage of a Jetstream Mk3 has 

five (5) low pressure ports and two (2) 
high pressure ports. These different 
types of ports are marked with IP for 
low pressure ports and HP for high 
pressure ports. All low pressure ports 
provide the same airflow.

•  Low and high pressure ports have 

different thread size to avoid accidently 
mounting components in the wrong 
port. If a hose connection does NOT fit 
in a port, do not use force/violence to 
connect the hose to the port. This could 
lead to accidents and injury.

•  Jetstream Mk3 is delivered with a hose 

adapter that makes it possible to use a 
low pressure hose with a 9/16” 
connection. It is possible to update a 
Jetstream Classic with this hose 
adapter (accessory) but if this is done, 
make sure the first stage used is 
equipped with an over pressure valve.

Before you assemble your Jetstream regulator, please pay attention to the following:

Low- and high pressure ports, 
Jetstream Classic

Hose connection, 
Jetstream Mk3

Low- and high pressure ports, 
Jetstream Mk3

Summary of Contents for Jetstream Classic

Page 1: ...JETSTREAM USER MANUAL 4 0 T M ...

Page 2: ......

Page 3: ...pprovals Certifications 6 Definitions Abbrevations 7 Jetstream 8 General safety regulations 9 Preparations 11 Regular maintenance service on your regulator 12 Assembly 13 Mounting the regulator on a tank 14 During a Dive 15 After Diving 16 Product Markings 18 Other 18 Accessories 19 Support 19 Technical data 20 ...

Page 4: ...2 ...

Page 5: ...hese boxes should not be ignored IMPORTANT Alert boxes that are BLUE contain important information about the proper care and maintenance of the Poseidon Jetstream and that may increase diver comfort or enhance enjoyment during dives This User s Guide is NOT intended for use as a training manual or in any way as a substitute for proper training through a legitimate training agency approved by Posei...

Page 6: ...Jetstream and to have a working knowledge of the procedures if a problem should arise No part of this book may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or by any information storage retrieval system without permission in writing from an authorized representative of Poseidon Diving Systems AB Text photographs and figures copy...

Page 7: ...l and at the same time feel the weightlessness when meter by meter you descent into a world of your own Nothing shall disturb your concentration No wheels or knobs that need adjusting No regulators that resist your breathing when you have reached your target depth No suits that limit your freedom of movement or get damaged at the slightest encounter This vision has accompanied Poseidon since the l...

Page 8: ...detail Type approvement certificate 955599S01 is issued by Finnish Institute of Occupational Health Department of Physics Topeliuksenkatu 41a A 00250 HELSINKI Finland Notified body 0403 Production quality assessment according to article 11 B of 89 686 EEC is assessed by SGS United Kingdom Ltd Ellesmere Port CH65 3EN UK Notified body number 0120 Poseidon Diving Systems AB is certified according to ...

Page 9: ...for any future warranty claim Jetstream Mk3 art nr 0100 005 1 pcs first stage art nr 0110 000 1 pcs second stage art nr 0120 005 1 pcs low pressure hose 70 cm 27 5 inch art nr 0130 000 1 pcs user guide Jetstream Octopus art nr 0100 006 1 pcs second stage art nr 0120 006 1 pcs low pressure hose 90 cm 35 4 inch art nr 0130 002 1 pcs user guide If any of the above mentioned items are missing from the...

Page 10: ... 5 inch art nr 4680 70 1 pcs user guide Jetstream Octopus art nr 2970 1 pcs second stage art nr 3546 1 pcs low pressure hose 90 cm 35 4 inch art nr 4680 90 1 pcs user guide IMPORTANT Low pressure hose with article number 4680 70 and 4680 90 has a built in over pressure valve Jetstream Classic can be updated with hose adapter 0000 130 accessory so that a low pressure hose with a 9 16 connection can...

Page 11: ...gen partial pressure must not exceed 3 2 bar 46 4 psi under the foreseeable maximum diving depth Inhaling cold gas and exhaling warmed gas represents energy losses of the human body thermal imbalance hypothermia This effect increases with increasing depth and can result in a sudden unconsciousness Diving to extreme depths this effect must be considered calculated and planned for and preventive act...

Page 12: ...health Diving deeper than 50m 164 ft using gasses other than air is more demanding on the equipment Most equipmenton the market is only approved for use within EN 250 limits WARNING The Jetstream regulators are not designed to be breathed up on by more then one person at a time If you configure your Jetstream regulator for more then one diver to breath from it at a time the cold water performance ...

Page 13: ...ot see any rubber in the inspection hole the hose should be discarded IMMEDIATLY and NOT used as it will pose an immediate risk of a hose failure accident Diving with a hose where rubber isn t visible in the inspection hole can be life threatening We recommend that you regularly replace your low pressure hoses to avoid situations where your safety is jeopardized by using worn out hoses It is often...

Page 14: ...tenance service should be performed about once every 100 dives or biannual whatever comes first Maintenance service should be performed by a service technician that is certified to service Poseidon equipment and only Poseidon original parts should be used It s recommended that you keep a record of the dates when service has been performed in the Notes section of this user manual so that you can ke...

Page 15: ...re ports All low pressure ports provide the same airflow Low and high pressure ports have different thread size to avoid accidently mounting components in the wrong port If a hose connection does NOT fit in a port do not use force violence to connect the hose to the port This could lead to accidents and injury Jetstream Mk3 is delivered with a hose adapter that makes it possible to use a low press...

Page 16: ...e connection wheel until you can feel that the first stage is firmly attached to the valve Carefully open the tank valve completely and then turn the valve knob half a turn in reverse Purge the second stage a couple of times to clear the second stage of any debris left from the previous dive Check the pressure gauge to make sure the tank is full Breath on the primary second stage and the octopus t...

Page 17: ...l always work and provide all the air you need There are no functionality or construction differences between a primary second stage and an Octopus The only difference is the color Water in the cylinder is the most common cause of freezing regulators The Cyklon should be used with gas according to EN 132 Annex A Jetstream USA Odin is fitted with a switch with and positions Since this regulator has...

Page 18: ...around the functional parts Purge the second stage while you rinse it to allow fresh water to access all parts of the second stage Blow the equipment dry by using air pressure After rinsing close the cylinder valve and purge the regulator Unscrew the regulator from the tank and mount the protective cap onto the connection Pack and store your regulator in your regulator bag This protects the regula...

Page 19: ... cold water poor visibility hard work and increased depth Always try to exercise prudent judgement when determining whether or not to dive Never dive when tired or in poor health WHAT YOU DO YOUR SELF After every dive the equipment should be cleaned according to the instructions in After diving The regulator does not have to be lubricated beyond what is done by Poseidon It is how ever recommended ...

Page 20: ...mended can seriously impair the function of your equipment Pressure gauge hoses without a restriction in the connection can if the hose is punctured allow a powerful jet of air to escape Self made and or by Poseidon unauthorized changes modifications to the product may lead to reduced functionality and failure resulting in personal injury or death Poseidon are NOT responsible for equipment where m...

Page 21: ...ed inflator hoses Support When you purchase a POSEIDON product you receive access to thousands of authorized service outlets world wide More information can be found and the latest manual is available for download on POSEIDON s homepage www poseidon com Poseidon s goal is to resolve errors problems covered by our warranty terms as close to the end consumers as possible thus resolving these issues ...

Page 22: ... stage 0120 005 Color Black Material ASA Stainless steel Brass Weight gram oz 190 gr 6 7 Oz VVolyme ml fl oz 80 ml 2 7 fl oz Valve technology Upstream Flow rate l min cft min 1800 l min 63 5 cft min Regulator 0100 005 Approved to depth m ft 50 m 164 ft Intermediate pressure bar psi 8 5 bar 123 psi Nitrox Yes max EAN 40 100 oxygen No Trimix max 21 oxygen Yes Compressed air Yes Working pressure 300 ...

Page 23: ... freez protection Accessory 1286 Second stage 2961 Color Black Material ASA Stainless steel Brass Weight gram oz 190 gr 6 7 Oz VVolyme ml fl oz 80 ml 2 7 fl oz Valve technology Upstream Flow rate l min cft min 1800 l min 63 5 cft min Regulator 3960 Approved to depth m ft 50 m 164 ft Intermediate pressure bar psi 8 5 bar 123 psi Nitrox No 100 oxygen No Trimix max 21 oxygen Yes Compressed air Yes Wo...

Page 24: ...ax EAN 40 LP hose length standard cm inch 90 cm 35 4 inch Tested to 50 m 164 ft Jetstream Classic Octopus Color Yellow Material ASA Stainless steel Brass Weight gram oz 190 gr 6 7 Oz VVolyme ml fl oz 80 ml 2 7 fl oz Valve technology Upstream Flow rate l min cft min 1800 l min 63 5 cft min Oxygen clean No LP hose length standard cm inch 90 cm 35 4 inch Tested to 50 m 164 ft Jetstream Mk3 Octopus ar...

Page 25: ...Poseidon Diving Systems AB Åkeredsvägen 1 SE 421 63 Västra Frölunda Sweden Phone 46 31 734 29 00 E mail info poseidon com www poseidon com ...

Reviews: