background image

 

11

 

 

Update 

 Bluetooth Serial Port Parameters 

 

Activate BlueTooth Serial Port Interface 

 

 

Device Name Broadcasting 

 

 

 

< Yes >

 

 

  

No 

 

Authentication 

 

 

 

Yes

 

 

  

No 

 

PIN Code 

Programming Instructions : (1) Read the label. (2) Program the desired character 
string by reading Hexadecimal Digits on page 50. One character consists of 2 
hexadecimal digits.  (3) Read the “Validate” label (also on page 50) to complete 
this setting. (4) Max 6 characters for this PIN Code setting. 

12

 

 

Enter Setup

Prefix / Postfix Settings 

 

 

 

Prefix Code *

 

 

  

Postfix 

Code 

Character Substitution 

  

 

 

Set 1 *

 

 

 

 

Set 2 *

 

 Set 

Programming Instructions : (1) Read the label. (2) Program the desired character 
string by reading Hexadecimal Digits on page 50. One character consists of 2 
hexadecimal digits.  (3) Read the “Validate” label (also on page 50) to complete 
this setting. 

Code ID Selection 

 

Clear All Code ID Settings 

 

 

Select Code ID Set 

 

 

 

Set 1

 

 

 

 

Set 2

 

 

Set 3

 

 

 

 

Set 4

 

 Set 

Summary of Contents for Xi2000-BT Series

Page 1: ...Guide POS X Inc 2130 Grant St Bellingham WA 98225 360 738 8533 U S Default Settings Sequence Enter Setup Reset Scanner Enable Auto Sense Mode ON UPC A Convert to EAN 13 OFF UPC E Lead Zero ON Save Cha...

Page 2: ...on 12 Code ID Setting 13 Length Code Setting 2 digits 14 Select Readable Codes 17 Code39 Parameters 22 Italy Pharmacode Parameters 22 French Pharmacode Parameters 23 Industrial 25 Parameters 23 Interl...

Page 3: ...F Auto Shutdown Duration Programming Instructions 1 Read the label 2 Program the desired auto shutdown duration in minutes by reading Decimal Digits on page 49 3 Read the Validate label also on page 4...

Page 4: ...zer Enable Buzzer Disable Buzzer Frequency 8 kHz 4 kHz 2 kHz 1 kHz 4 Enter Setup Reading Redundancy Setting No Redundancy 2 Times 3 Times 4 Times Scan Mode Setting Auto Off Mode Continuous Mode Auto P...

Page 5: ...he desired keyboard number shown in the following table by reading Decimal Digits on page 49 3 Read the Validate label also on page 49 to complete this setting Keyboard Table No Keyboard Type 1 PCAT U...

Page 6: ...ck ON Capital Lock OFF Auto Detection 8 Enter Setup Alphabet Transmission Case Sensitive Ignore Case Digits Transmission Alphanumeric Key Numeric Key Alt Composing Yes No Inter Character Delay Program...

Page 7: ...en Odd No Parity Data Bit 8 7 10 Enter Setup Flow Control None Scanner Ready Data Ready INV Data Ready Inter Character Delay Programming Instructions 1 Read the label 2 Program the desired inter chara...

Page 8: ...date label also on page 50 to complete this setting 4 Max 6 characters for this PIN Code setting 12 Enter Setup Prefix Postfix Settings Prefix Code Postfix Code Character Substitution Set 1 Set 2 Set...

Page 9: ...desired character string by reading Hexadecimal Digits on page 50 One character consists of 2 hexadecimal digits 3 Read the Validate label also on page 50 to complete this setting 14 Enter Setup Lengt...

Page 10: ...Length Code Enable Disable EAN8 Length Code Enable Disable EAN13 Length Code Enable Disable 16 Enter Setup Code 93 Length Code Enable Disable Code 128 Length Code Enable Disable EAN128 RSS Length Cod...

Page 11: ...rmacode Enable Disable French Pharmacode Enable Disable Industrial 25 Enable Disable Interleave 25 Enable Disable 18 Enter Setup Matrix 25 Enable Disable Codabar Enable Disable Code 93 Enable Disable...

Page 12: ...sable No Addon Enable Addon2 Disable Addon2 Enable Addon5 Disable Addon5 20 Enter Setup UPCE Enable No Addon Disable No Addon Enable Addon2 Disable Addon2 Enable Addon5 Disable Addon5 EAN8 Enable No A...

Page 13: ...Disable RSS Limited Enable Disable RSS Expanded Enable Disable 22 Enter Setup Code39 Parameters Standard Full ASCII Code39 Standard Full ASCII Start Stop Transmission Enable Disable Checksum Verificat...

Page 14: ...Max Min Code Length Qualification Select Max Min Length Qualification Max Length Min Length Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 Fixed Length 2 Programming...

Page 15: ...Validate label also on page 49 to complete this setting 26 Enter Setup Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 Fixed Length 2 Programming Instructions 1 Read t...

Page 16: ...am the desired length by reading Decimal Digits on page 49 3 Read the Validate label also on page 49 to complete this setting Codabar Parameters CLSI Conversion Enable Disable Start Stop Transmission...

Page 17: ...e 49 to complete this setting 30 Enter Setup Fixed Code Length Qualification Select Fixed Length Qualification Fixed Length 1 Fixed Length 2 Programming Instructions 1 Read the label 2 Program the des...

Page 18: ...ert to EAN13 Enable Disable System Number Transmission Enable Disable Checksum Transmission Enable Disable 32 Enter Setup UPCE Parameters System Number Selection System Number 0 and 1 System Number 0...

Page 19: ...isable ISSN Conversion Enable Disable Checksum Transmission Enable Disable 34 Enter Setup RSS Code ID Selection C1 e0 RSS14 Parameters Code ID Transmission Enable Disable Application ID Transmission E...

Page 20: ...on Enable Disable Checksum Transmission Enable Disable RSS Limited Parameters Code ID Transmission Enable Disable 36 Enter Setup Activate Editing Formats Format 1 Enable Disable Format 2 Enable Disabl...

Page 21: ...also on page 49 to complete this setting Matching String of Applicable Data Programming Instructions 1 Read the label 2 Program the desired character string by reading Hexadecimal Digits on page 50 O...

Page 22: ...nd of Format Programming Applicable Code Type All Clear Code 39 Italy Pharmacode French Pharmacode Industrial 25 Interleave 25 Matrix 25 Codebar Code 93 Code 128 EAN128 RSS UPCE No Addon UPCE Addon2 U...

Page 23: ...ram the desired character string by reading Hexadecimal Digits on page 50 One character consists of 2 hexadecimal digits 3 Read the Validate label also on page 50 to complete this setting Include Term...

Page 24: ...cimal Digits on page 49 3 Read the Validate label also on page 49 to complete this setting 44 End of Format Programming Field3 Setting Divide Field by Field Terminating String Field Terminating String...

Page 25: ...cimal Digits on page 49 3 Read the Validate label also on page 49 to complete this setting 46 End of Format Programming Field5 Setting Divide Field by Field Terminating String Field Terminating String...

Page 26: ...hexadecimal digits 3 Read the Validate label also on page 50 to complete this setting 48 End of Format Programming Field Transmission Sequence Start Field 1 Additional Field 1 Field 2 Additional Fiel...

Page 27: ...49 Update Decimal Digits 0 5 1 6 2 7 3 8 4 9 Validate 50 Enter Setup Hexadecimal Digits 0 8 1 9 2 A 3 B 4 C 5 D 6 E 7 F Validate...

Page 28: ...p 1 SOH DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT...