PORTMAN GT3200ST Operation Manual Download Page 3

 

2

The event trigger report is also configurable. User can turn on or off any event generated report from the PC 
setup program or via the air command. The event triggered report include (1) In-vehicle Door close/open (2) 
In-vehicle ignition on/off (3) Temperature range in/out the preset range (4) In-vehicle shock sensor trigger. 
The build in alarm (optional) trigger reports are also configurable and can be set from PC setup program or 
air command.   

 

The server can not only configure the device just like the PC setup program does, but it also can send the 
command to control the device. The server can control both the device and the build in alarm.   

 

1.3 Geofence function 
The device has built-in 30 Geofence sets (1 immediate geofence, 4 circular, 5 rectangular and 20 point), it 
will send the report to the server if the Geofence event is triggered. User can setup the Geofence area from 
the PC setup program or sending the define. 
A unique immediate Geofence function:   
‘Immediate-Geofence function’ is a circular type Geofence which can be activated or deactivated from a 
single button. When activated, the system will record the current position and use the pre-defined radius as a 
circular Geofence to guard the vehicle. If the vehicle moves out of the preset Geofence zone, a report will be 
generated to the server. User can deactivate the self-Geofence at any time by pressing the button again. If the 
GPS cannot be located when the Immediate Geofence function is been executed, GT3200ST will used the 
last known position as the origin of the circular Geofence zone to perform the protection. 

 

1.4 Store and forward ability 
When there is no GPRS service or the server close. The unit will send short message to the server if defined 
SMS number. All the stored report will be forward to the server when GPRS connection is completed next 
time. 

 

1.5 TCP and UDP socket support 
GT3200ST supports both UDP and TCP socket communication. The server IP, port number and socket type 
can be selected from the PC-setup program or remote server command. In addition, the connection can be 
swap over to any server IP or port (either UDP or TCP) via the air command.   

 

1.6

 

The server can send the command to control the device and the build in alarm. 

Command for in-vehicle control: 
We design 7 commands which can be integrated into the server, so that the users can control their vehicles. 
Those commands are: (1) Door lock, (2) Door unlock, (3) Arming, (4) Panic, (5) Enable anti-car jacking, (6) 
Emergency release, (7) Trunk output 
Notes: 

1.

 

Arming (this command is valid only if when ACC is off): If ACC Off, Server send arming command. 
The door will lock and the Engine will be Disable starter (if the starter cut relay connected), after the 
unit received the command. 

2.

 

Panic: (can be performed at any time) If Server send panic command, the horn will sound and parking 
lights will flash for 30 seconds after the unit received the command. 

3.

 

Enable anti-car jacking: (can be performed at any time) If Server send anti-car jacking command, the 
system will enter anti-carjacking mode after the unit received the command. Enter the anti-carjacking 

Summary of Contents for GT3200ST

Page 1: ...OPERATION MANUAL GPS GPRS CAR ALARM GT3200ST ...

Page 2: ...Report configuration parameters user can remotely change the report configuration and the configuration parameters will be shown in this field 1 2 Report Setup GT3200ST must be initialized by PC setup program in order to make communication with the remote server call center There are seven main sections that allow users to program the device 1 User detail Device ID server IP and port SMS number GP...

Page 3: ...ce function is been executed GT3200ST will used the last known position as the origin of the circular Geofence zone to perform the protection 1 4 Store and forward ability When there is no GPRS service or the server close The unit will send short message to the server if defined SMS number All the stored report will be forward to the server when GPRS connection is completed next time 1 5 TCP and U...

Page 4: ...operation Optional User can use the supplied handset HS200 to perform the function such as send receive SMS phone in out main unit status display etc For detail refer to the user manual of HS200 1 10 History report Flash memory for recording reports up to 6000 reports It can be read out from the PC setup program via serial port 1 11 Internal battery The system has a built in rechargeable battery 4...

Page 5: ...uto answer the phone in the following 10 minutes The system will auto exit monitor mode after 10 minutes II BASIC FUNCTIONS FUNCTIONS APPLICATIONS GPS GPS receiver will output a complete position velocity and time PVT solution in the NMEA Version 3 0 protocol GPRS SMS GPRS use standard TCP or UDP communicate protocol If the GPRS service is failed the SMS mode will be turned on for emergency use 9 ...

Page 6: ...ld in ALARM Optional If build in alarm is installed the system will gather all the alarm information for the remote monitoring The server also has the ability to control the build in alarm Standard Report Automatic report for AVL tracking purpose Fixed time report Fixed distance report Intelligent report combine time and distance Keep alive report Event Report Temperature report Speeding report Lo...

Page 7: ...e it when the LED flashes once After releasing it the LED will stay continuously on to indicate the Immediate Geofence is on To deactivate Press the button the LED will be temporally off and release it when the LED flashes once After releasing it the LED will then stay continuously off A report will be sent out if the vehicle goes out in to the Geofence zone 3 Activate Deactivate panic mode and se...

Page 8: ...ndicator This LED will be ON when the unit received a valid GPS data Note that the Green LED indication will not be valid until the system goes to the working mode normally 30 seconds after power on VI BUILD IN ALARM OPERATION Optional User can use the BUILD IN ALARM to perform all the car alarm function For detail refer to the BUILD IN ALARM OPERATION manual VII PC SETUPAND SYSTEM INITIATION PC s...

Page 9: ...8 B Version No Checking The below interface will last until correct UNIT Version No is checked You should run this program before turn on power of UNIT C MAIN INTERFACE 1 User detail ...

Page 10: ...therwise it displayed with space Set UNIT ID and UNIT password of for the device Set Access Point Name APN User Name Password The maximum length of the APN User name and Password is 49 characters TCP UDP address and Port number of the remote server being set UNIT will send report to these address Note that only one TCP or UDP server will be used at the same time To select enable or disable local G...

Page 11: ... report will show B in GPS fix section If the number of satellite is less than 3 then the report will show L in GPS fix section UNIT can save 6000 reports 6000 1 recently Click Export button can export them with Excel or Text format Initialize button clear all data in UNIT Request All read out the whole existing setting from GT3200ST Request read out the setting in the current page Apply transfer ...

Page 12: ...11 2 Geofence ...

Page 13: ... set the reports send or local or ignore Send report will send out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports Five rectangular geofence Set two points position the point format is N2446 5321E12120 4231 With two points generate one rectangle Unit will detect whether in rectangle When unit enter or leave rectangle will send ...

Page 14: ...13 20 point Geo fence areas can be set When UNIT is out of these predefined zones a report will be generated ...

Page 15: ...14 3 Local report Automatic report can be configured in this section To activate the function s please select in checkbox and fill in data in the textbox ...

Page 16: ... km Hr 3 IO connect selection Parameters to select either temperature sensor or AD1 4 Temperature report Parameters On Off and min and max temperature 5 AD detect report AD1 on off SEND REPORT IF ADC1 LESS THAN min voltage V for debounce time SEC RESEND PER resend time SEC on off SEND REPORT IF ADC1 MORE THAN max voltage V for debounce time SEC RESEND PER resend time SEC on off SEND REPORT IF ADC1...

Page 17: ...urse change is bigger than the value set here Parameters On Off course change in degree and debounce time 10 Low battery warning report to alert user when the external battery level is low Parameters On Off and warning battery level for report For example 50 to represent 50 lower level report The system will ignore the parameter with a value 0 to prevent continuous non stop reporting 11 Speed repo...

Page 18: ...he max reconnect times Each retry will be separated by the reconnect interval 3 GPRS connect once While using this mode the unit will connect to the server when there is a report to send but only try once If it is not successful the report will be stored and sent out in the next successful connection Disconnect GPRS connection when report sending is completed 4 Reduce GPRS dialup method Parameters...

Page 19: ...end any data in this 20 mins including keep alive or normal reports then it will send a keep alive packet to check if the GPRS connection is valid or not If not it will actively reconnect to GPRS network Special command for SMS mode If the GT3200ST is not in the GPRS online status user can send command Y02 or Y04 to ask unit to connect to server This command can be sent from any device via SMS Y02...

Page 20: ...9 All the roam reports configured are same as Local report Send report will send out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports ...

Page 21: ...T3200ST can go to sleep mode when ACC goes off and crash sensor and optional shock sensor not be trigger for 5minuts In sleep mode GPS will be disabled All the auto report Time Distance Intelligent will not be send when ACC goes off 2 During the sleep mode the system can wait up automatically and send a wake up diagnostic report The automatic wakeup time is configurable Minimum duration is 5 minut...

Page 22: ...roam alarm mode use can set all the alarm reports send or local or ignore Send report will send out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports 7 Roam setting ...

Page 23: ...ocal GPRS compressing N reports to a packet and then send out N the digit between 1 8 2 To send report in roam GPRS compressing N reports to a packet and then send out N the digit between 1 8 3 To send report in local SMS compressing N reports to a SMS and then send out N the digit between 1 5 4 To send report in roam SMS compressing N reports to a SMS and then send out N the digit between 1 5 APP...

Page 24: ...bile station class B SIM card interface 3 4 4 5V SMS storage Capacity 40 in ME Antenna Connector Silver Male TNC or SMA Antenna Impedance 50ohms GPS Data provided by TYCO Channels 20 parallel tracking Correlators 200 000 plus Frequency L1 1575 MHz Sensitivity Tracking 159 dBm Acquisition Cold start 142 dBm Position accuracy Horizontal 2 5m CEP autonomous 2 0m CEP SBAX Time to first fix Hot start 1...

Page 25: ...ith optional build in alarm Environmental Operating Temperature 20 C to 55 C Storage Temperature 40 C to 85 C Optional Accessories 1 Combined Antenna with GPRS and active GPS 2 Temperature sensor 3 Ultrasonic sensor 4 Shock sensor 5 PC setup Cable 6 Handset Note Using wrench to tighten the screw cap of GPS and GPRS antenna and lock the screw cap to fix position for avoid antenna connect abnormalit...

Page 26: ...NAL RF ANT MIC HANDFREE OPTIONAL HANDSET BLACK RED PURPLE 300mA OUTPUT RESET RED LED POWER INDICATOR GREEN LED GPS INDICATOR YELLOW LED GSM INDICATOR GSM ANT GPS ANT VALET SWITCH LED 2 KEYPAD I II BUZZER WHITE RED HORN 300mA OUTPUT BROWN TG WHITE TG ORANGE 300mA OUTPUT OPTIONAL PARKING LIGHT RELAY 12 or 24V BLUE LOCK OUTPUT 300mA GREEN UNLOCK OUTPUT 300mA OPTIONAL 12V OR 24V RELAY 85 30 87 86 TRUN...

Page 27: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or rel...

Page 28: ...ting in conjunction with any other antenna or transmitter 2 This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body ...

Reviews: