PORTMAN GT2000 Operation Manual Download Page 5

 

4

Press button1 for 
2sec. 

Power LED flash quickly 3 times 
then restore normal 

Send SOS report 

No incoming call is 
received 

Press button2 once  Power LED restore normal 

Hang up the call. 

When a call come or in 
communication or Dialing 
out 

Power LED flash 2 times orange 
and 1 time green

if low power 

then red

 every 3sec. 

Send SOS report and into 
monitor mold. 

No incoming call is 
received no in monitor 
mold 

Press button2 for 
2sec. 

Power LED restore normal 

Exit monitor mold 

No incoming call is 
received in monitor mold

Press button3 for 
2sec. 

Power LED flash quickly 5 times 
then restore normal 

Send help report 

No incoming call is 
received 

 

Power LED change to orange and 
flash quickly. 

 

When a call come or 
Dialing out 

Press button3 once 
then press button1 
once within 2sec. 

Power LED change to orange and 
flash quickly. 

Auto dialing out the first 
telephone No. of preset by 
PC-setup. 

No incoming call is 
received 

Press button3 once 
then press button2 
once within 2sec. 

Power LED change to orange and 
flash quickly. 

Auto dialing out the 
second telephone No. of 
preset by PC-setup. 

No incoming call is 
received 

Press button3 once 
then press button3 
once within 2sec. 

Power LED change to orange and 
flash quickly. 

Auto dialing out the third 
telephone No. of preset by 
PC-setup. 

No incoming call is 
received 

Press button ‘-“once  As normal 

Ring or sound become 
low 

If speaking, change sound

Press button ‘+” once As normal 

Ring or sound become 
high 

If speaking, change sound

Press button “+” for 
2sec.  

As normal 

Change to vibrate, ring or 
ring + vibrate together 
modes 

 

Power LED indication priority

 

1

call coming or communication or Dialing out 

2

SOS report 

3

help report 

4

monitor mold 

5

Self-Geofence 

6

charging 

7

power on/off and low power 

Summary of Contents for GT2000

Page 1: ...GPS GPRS PERSONAL TRACKING GT2000 OPERATION MANUAL ...

Page 2: ...fence event is triggered The UNIT must be initialized by PC setup program in order to make communication with the remote server call center There are three main sections that allow users to program the device 1 User detail Device ID server IP and port GPRS APN 2 Geo fence 5 circular Geo fence 3 Report Time Distance speed Low battery wakeup A unique help report user can press the Button 3 for 2 sec...

Page 3: ...ly on when the unit received a valid GPS data Note that the YELLOW and GREEN LEDs indication will not be valid until the system goes to the working mode normally 30 seconds after power on II BASIC FUNCTIONS FUNCTIONS APPLICATIONS GPS GPS receiver will output a complete position velocity and time PVT solution in the NMEA Version 3 0 protocol GPRS SMS GPRS use standard TCP or UDP communicate protoco...

Page 4: ...s power switch button for 3sec Power LED off Power OFF Power on If charging then power LED is red if charge ok then power LED change to green Charging Press button1 once Power LED change to orange Answer the coming call When an incoming call is received Power LED flash 2time 3sec Self Geofence ON No incoming call is received and self Geofence off Press button1 once Power LED restore normal Self Ge...

Page 5: ...nce within 2sec Power LED change to orange and flash quickly Auto dialing out the first telephone No of preset by PC setup No incoming call is received Press button3 once then press button2 once within 2sec Power LED change to orange and flash quickly Auto dialing out the second telephone No of preset by PC setup No incoming call is received Press button3 once then press button3 once within 2sec P...

Page 6: ...indow Connect UNIT DB9 port to the PC serial port with a standard serial cable Select the COM port and click OK Note that it is necessary to power on the device soon after starting the PC setup program PC setup program will detect the hardware for 60 seconds If no hardware is detected it will exit During the opening up screen shown as below user can press Esc key to terminate the program B Version...

Page 7: ...sword The maximum length of the APN User name and Password is 49 characters TCP UDP address and Port number of alarm center being set UNIT will send message to these address Note that either TCP or UDP should be selected Note that the IP address and port must input correctly otherwise it will cause fail to make a call UNIT can save 900 reports 900 1 recently Click Export button can export them wit...

Page 8: ...est All read out the whole existing setting from GT8000 GT8500 Request read out the setting in the current page Apply transfer the setting to GT8000 GT8500 in the current pages Apply All transfer the whole setting to GT8000 GT8500 Load load the saved configuration files Save save the current configuration setting to a file Exit button exit PC Setup to main program 2 Geo fence Setup the circular Ge...

Page 9: ...f there is no report to send Note that user can configure the wakeup report if the device is in stop not moving state Normal mode report will be summarized as 1 Fixed time report Parameters On Off and time 2 Fixed distance report Parameters On Off and distance min distance is 0 1 km max distance is 100 km 3 Keep alive report Parameters On Off and interval time retry times Keep alive enable system ...

Page 10: ...is in stop status user can let the GPS go to sleep mode for power saving If select GPS Sleep ON user can setup the wakeup report configuration or NO GPS wakeup report IF select GPS Sleep OFF GT 2000 will follow the report sending rule in When Moving section Power saving mode While in Power saving mode GT 2000 will cut off the GPS power if there is no report to send Report configuration will be lis...

Page 11: ... 300mA Current Sleep 6 12mA when GPS is in sleep mode Battery Battery type Battery capacity Charge type Battery Lithium 3 6V 1600mAh Built in charge circuit GPRS Frequency Range MHz 900 1800 and 850 1900 models Channel spacing Hz 200 GPRS connectivity GPRS multi slot class 8 GPRS mobile station class B SIM card interface 3V 5V SMS storage Capacity 40 in ME Antenna Impedance 50ohms Antenna Type Emb...

Page 12: ...e on off Pressing II twice within 2 seconds will put the unit into Taxi mode Pressing II twice again within 2 seconds will take the unit out of Taxi mode When the unit enters Taxi mode the top LED will flash 3 times 3sec and unit will vibrate once every minute When in Taxi mode the unit will automatically vibrate every one minute When the unit vibrates at these intervals the user must press II wit...

Page 13: ...uraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help VII Operation is subject to the following tw...

Reviews: