15
Parameters: report time when moving, report time when stop, threshold speed, send stop
report after a preset value and to choose the reports send or ignore.
Report when speed less than a preset value (refer the following 1.5 Km/Hr), and it will send
stop report after the preset time (refer the following 120Sec). (min. speed is 0.1 km/Hr, max.
speed is 1000 km/Hr).
(2) Local Intelligent history report (record the report in the system’s flash ram)
Parameters: Report time when moving, Report time when stop, and threshold speed. (min.
speed is 0.1 km/Hr, max. speed is 1000 km/Hr). and to choose the reports send or ignore.
(3) A/D 1 detect report
[on/off] SEND REPORT IF ADC1 LESS THAN [min voltage] V for [debounce time] SEC,
RESEND PER [resend time] SEC
[on/off] SEND REPORT IF ADC1 MORE THAN [max voltage] V for [debounce time]
SEC, RESEND PER [resend time] SEC
[on/off] SEND REPORT IF ADC1 GO UP [up voltage] V for [debounce time] SEC
[on/off] SEND REPORT IF ADC1 GO DOWN [down voltage] V for [debounce time] SEC
[on/off] SEND REPORT IF ADC1 ENTER/EXIT [min voltage] V TO [max voltage] V for
[debounce time] SEC
Note: AD1 input voltage range is 0~3.30v, it must connect a resistance to share the voltage
if the detected voltage higher than 3.30v.