background image

 

                                                                                                                 

15

Parameters: report time when moving, report time when stop, threshold speed, send stop 
report after a preset value and to choose the reports send or ignore. 
Report when speed less than a preset value (refer the following 1.5 Km/Hr), and it will send 
stop report after the preset time (refer the following 120Sec). (min. speed is 0.1 km/Hr, max. 
speed is 1000 km/Hr). 

 

(2)  Local Intelligent history report (record the report in the system’s flash ram) 

 

Parameters: Report time when moving, Report time when stop, and threshold speed. (min. 
speed is 0.1 km/Hr, max. speed is 1000 km/Hr). and to choose the reports send or ignore. 

 

(3)  A/D 1 detect report 

 

[on/off] SEND REPORT IF ADC1 LESS THAN [min voltage] V for [debounce time] SEC, 
RESEND PER [resend time] SEC                                     

 

[on/off] SEND REPORT IF ADC1 MORE THAN [max voltage] V for [debounce time] 
SEC, RESEND PER [resend time] SEC 

 

 

 

 

     

 

 

[on/off] SEND REPORT IF ADC1 GO UP [up voltage] V for [debounce time] SEC   

 

[on/off] SEND REPORT IF ADC1 GO DOWN [down voltage] V for [debounce time] SEC   

 

[on/off] SEND REPORT IF ADC1 ENTER/EXIT [min voltage] V TO [max voltage] V for 
[debounce time] SEC  
 
Note: AD1 input voltage range is 0~3.30v, it must connect a resistance to share the voltage 
if the detected voltage higher than 3.30v. 
 

Summary of Contents for GST8000

Page 1: ...Portman Security Systems Ltd Operation Manual GPRS GPS TRACKING SYSTEM Model GST8000 Version 2 0 ...

Page 2: ...4 or equal to 4 B mean the number of satellite is equal to 3 L mean the number of satellite is less than 3 3 Time report time in Greenwich Mean time zone 4 GPS s latitude and longitude 5 Speed in km H 6 Direction in degree to the North 7 Temperature in Celsius If the temperature is not connected NA will be shown in this field 8 Device s status there are 32 states to represent the I O and working m...

Page 3: ... mode can be categorized as time report distance report or time velocity report User can choose the reporting mode and related parameters via the PC setup program or the remote sever The event trigger report is also configurable User can turn on or off any event generated report from the PC setup program or via the air command The event triggered report include 1 In vehicle Door close open 2 In ve...

Page 4: ...ber and socket type can be selected from the PC setup program or remote server command In addition the connection can be swap over to any server IP or port either UDP or TCP via the air command 1 6 Valet switch operation User can use the supplied Valet switch to perform 7 essential tasks including 1 sending help report 2 activate or deactivate Immediate Geofence 3 sending Duty on or Duty off repor...

Page 5: ...rs for waking the device up are selectable When ignition is on the system will back to working mode and stay connected to the TCP UDP server in GPRS network 1 12 Iridium satellite short burst data support GST8000 support satellite short burst data While there is no GSM coverage Iridium satellite module start communicates with server Unit sends compressed report to server and server can send comman...

Page 6: ...p alive report Event Report Temperature report Speeding report Low battery report Geofence trigger report Wake up report ALARM trigger report e g ARM ignition inputs etc History data store 900 report can be saved in unit and read from server and pc setup Valet switch OPERATION 1 Sending help report Press the button once The LED will flash once and a help report will be generated 2 Activate or deac...

Page 7: ...wer indicator When the unit power on the led will light all the time When power cut off the unit works with backup battery the led will flash until all the report is sent to server While satellite module works fine red led flash twice every 2 seconds YELLOW GSM GPRS indicator Yellow LED will flash when the device is connected to the server with valid GPRS connection It will stay continuously on wh...

Page 8: ...ton and next click OK Note that it is necessary to power on and reset the PORTMAN device soon after click the ok button PC setup program will detect the hardware for 60 seconds If no hardware is detected it will exit During the opening up screen shown as below user can press Esc key to terminate the program B Version No Checking The below interface will last until correct UNIT Version No is checke...

Page 9: ...otected user can input the SIM PIN window to set password of SIM Card Set UNIT ID and UNIT password of for the device Note Device ID length does not more than 4 characters otherwise SBD compressed packet will more than 30 bytes and communication data fee is double ...

Page 10: ...t only one TCP or UDP server will be used at the same time To select enable or disable local GPRS SMS or Roam GPRS SMS Set the SMS Number of the user The unit will send reports to the user if GPRS connection is failed AUTO GPS fix the report will be display A in the report and indicate that if the number of satellite is more than 3 or equal to 3 If the number of satellite is less than 3 then it wi...

Page 11: ... export them with Excel or Text format To select ID card enable or disable ID card control start kill enable or disable ID card send report enable or disable If ID card control start kill enable was selected the unit will disarm by ID card only or emergency release Initialize button clear all data in UNIT Request All read out the whole existing setting from GST8000 Request read out the setting in ...

Page 12: ...ection fails the report will be sent to the primary SMS number first The report will be resent when the GPRS connection becomes available 2 Geofence Four Circular Geofence and one self geofence Circular Geofence must set origin and radius Origin format N2446 5321E12120 4231 ...

Page 13: ...out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports Five rectangular geofence Set two points position the point format is N2446 5321E12120 4231 With two points generate one rectangle Unit will detect whether in rectangle When unit enter or leave rectangle will send one message out ...

Page 14: ...13 20 point Geo fence areas can be set When UNIT is out of these predefined zones a report will be generated ...

Page 15: ...3 Report Automatic report can be configured in this section To activate the function s please select in checkbox and fill in data in the textbox The reports will be summarized as 1 Local Intelligent report ...

Page 16: ...nd threshold speed min speed is 0 1 km Hr max speed is 1000 km Hr and to choose the reports send or ignore 3 A D 1 detect report on off SEND REPORT IF ADC1 LESS THAN min voltage V for debounce time SEC RESEND PER resend time SEC on off SEND REPORT IF ADC1 MORE THAN max voltage V for debounce time SEC RESEND PER resend time SEC on off SEND REPORT IF ADC1 GO UP up voltage V for debounce time SEC on ...

Page 17: ...DC2 GO DOWN down voltage V for debounce time SEC on off SEND REPORT IF ADC2 ENTER EXIT min voltage V TO max voltage V for debounce time SEC Note AD2 input voltage range is 0 3 30v it must connect a resistance to share the voltage if the detected voltage higher than 3 30v 5 Speeding report Parameters resend interval threshold speed over speed delay time exit over speed delay time alert when over sp...

Page 18: ... short keep alive report to the server in order to prevent the disconnection from the mobile service provider Send reports after a successful keep alive ACK Parameters On Off If you select this function all the reports will only be sent out after a successful keep alive ACK So if your keep alive time is shorter then select this function will be OK This function is very useful while using UDP to pr...

Page 19: ...report when the course change is bigger than the value set here Parameters Course change in degree and report send or ignore 10 Fixed report Parameters The time of local fixed time report and report send or ignore The distance of local fixed distance report and report send or ignore min distance is 0 1 km max distance is 100 km 11 GPRS Dial up procedure ...

Page 20: ...uccessful connection Disconnect GPRS connection when report sending is completed 4 Reduce GPRS dialup method Parameters On Off Max reconnect times connect delay If this method is used the unit will reduce the GPRS dial up connection when the dial up is failed after number of times User can define the delay time for the unit before try to reconnect to the server If there is trigger report the unit ...

Page 21: ...m alarm All the roam reports configured are same as Local report Send report will send out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports ...

Page 22: ...nally Also build in car alarm function can be set on here Sleep mode when ignition OFF 1 GST8000 can go to sleep mode when ignition goes off and TL sensor not be trigger for 5minuts In sleep mode GPS will be disabled All the auto report Time Distance Intelligent will not be send when ignition goes off 2 During the sleep mode the system can wait up automatically and send a wake up diagnostic report...

Page 23: ...IGL or TRIGH command TRIGL TRIGL will set the input to trigger on LOW ground TRIGH TRIGH will set the input to trigger on HIGH 12V SMS alert when the item s were selected valid the related reports will be sent by SMS Debounce time s the delay time for report sending If input 1 with distance is selected system will send the distance report every time ignition ON to ignition OFF for example GST8000 ...

Page 24: ...am alarm All the roam alarm configured are same as Local report Send report will send out immediately if generation Local report will save if generation it will send out by local network Ignore cancel reports ...

Page 25: ...24 7 GSM roaming 1 Roaming GPRS mode ...

Page 26: ...2 Compress setting 1 To send report in local GPRS compressing N reports to a packet and then send out N the digit between 1 8 2 To send report in roam GPRS compressing N reports to a packet and then send out N the digit between 1 8 3 To send report in local SMS compressing N reports to a SMS and then send out N the digit between 1 4 4 To send report in roam SMS compressing N reports to a SMS and t...

Page 27: ...splay automatically otherwise it displayed with space This report is special for satellite module It is different to intelligent report defined in common report setting This report only work when no GSM coverage Attention because consumption with satellite is different to GPRS SMS Pay attention to report frequency ...

Page 28: ...ay attention to report frequency Set time how often to check inbox After get command from server unit will analyze command and feed back Attention User must pay for every time to check SBD inbox Besides actively check inbox satellite check inbox once while send report to server Set delay time before satellite module power on After unit detected GSM register fail unit need a little time to confirm ...

Page 29: ... Up to 20 ID numbers can be saved when the ID list was set here if unit didn t detect valid ID or invalid ID was detected the ignition won t be started if the ID list was not set then user can start the ignition without ID card To learn ID card in PC SETUP use the same way to learn ID card by using valet switch Password the password is used for release start kill by inputting card password through...

Page 30: ...odule are off Current SBD standby 120mA Current SBD transmit 200mA Backup Battery Internal for emergency report Battery type 6V 2 pcs battery Battery capacity 1 3A H Charge type Built in charge circuit GPRS Frequency Range MHz 850 900 1800 1900 GPRS connectivity GPRS multi slot class 10 GPRS mobile station class B SIM card interface 3V Antenna Impedance 50ohms GPS Channels 20 parallel tracking Fre...

Page 31: ...DC supply voltage 5V Baud Rate 19200 Frequency range 1616 MHz to 1626 5 MHz Input Output Impedance 50Ω Multiplexing Method TDMA FDMA Duplexing Method TDD Time Domain Duplex Average Power during a transmit slot max 1 6W Communication GPRS SMS USB Environmental Operating Temperature 20 C to 55 C Storage Temperature 40 C to 85 C PACKING LIST 1 Unit 2 Main wire harness 3 User manual 4 Valet LED wire 5...

Page 32: ...31 ...

Page 33: ...32 ...

Page 34: ...equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from...

Reviews: