English
10
WARning lABEl REPlACEMEnT
If your warning labels become illegible or are missing, call
(888) 848-5175 for a free replacement.
4825 Highway 45 North
Jackson, Tennessee 38305
(888) 848-5175
www.portercable.com
Troubleshooting Guide
BE sURE TO FOllOW sAFETY RUlEs AnD insTRUCTiOns
For assistance with your product, visit our website at www.portercable.com for a list of service centers, or call the
PORTER-CABLE Customer Care Center at (888) 848-5175.
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTION
Unit will not start.
Cord is not plugged in.
Circuit fuse is blown.
Circuit breaker is tripped.
Cord or switch is damaged.
Plug tool into a working outlet.
Replace circuit fuse. (If the product repeatedly
causes the circuit fuse to blow, discontinue
use immediately and have it serviced by an
authorized PORTER-CABLE service center.
Reset circuit breaker. (If the product repeatedly
causes the circuit breaker trip, discontinue
use immediately and have it serviced by an
authorized PORTER-CABLE service center.
Have cord or switch replaced at an authorized
PORTER-CABLE service center.
Saw makes unsatisfactory cuts.
Dull cutting wheel.
Not enough water in the tub.
Cutting wheel mounted backwards.
Build up on cutting wheel
Incorrect cutting wheel for work being done.
Replace cutting wheel.
Check water level and add water if necessary.
Turn cutting wheel around.
Use dressing stone to remove build up.
Change the cutting wheel.
Unit does not make accurate cuts.
Edge guide not secure to fence.
Cutting wheel is not square to fence.
Cutting wheel is not perpendicular to
cart surface.
Workpiece moving.
Check and adjust.
Check and adjust.
Check and adjust fence.
Use edge guide.
Unit vibrates excessively.
Saw not mounted on a level surface.
Damaged saw cutting wheel.
Reposition on a level surface.
Replace cutting wheel.
Cutting wheel does not come up to speed.
Arbor loose.
Tighten arbor.