Porter-Cable CPLMC7580V2C Instruction Manual Download Page 3

3- ENG

D24225

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS 

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN
SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL
WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

RISK OF EXPLOSION OR FIRE

ALWAYS 

OPERATE THE COMPRESSOR IN A

WELL VENTILATED 

AREA FREE OF

COMBUSTIBLE MATERIALS, GASOLINE OR
SOLVENT VAPORS. 

IF SPRAYING FLAMMABLE MATERIALS,

LOCATE COMPRESSOR AT LEAST 20 FEET
AWAY FROM SPRAY AREA. 

AN ADDITIONAL

LENGTH OF HOSE MAY BE REQUIRED.

STORE FLAMMABLE MATERIALS IN A
SECURE LOCATION AWAY FROM
COMPRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON
TOP OF COMPRESSOR.  OPERATE
COMPRESSOR

IN AN OPEN AREA 

AT LEAST

12 INCHES AWAY FROM

ANY  WALL OR

OBSTRUCTION

THAT WOULD RESTRICT THE

FLOW OF FRESH AIR TO THE VENTILATION
OPENINGS.

OPERATE COMPRESSOR IN A CLEAN, DRY,
WELL VENTILATED AREA.  

DO NOT OPERATE

UNIT INDOORS OR IN ANY CONFINED AREA.

ALWAYS REMAIN IN ATTENDANCE WITH
THE PRODUCT WHEN IT IS OPERATING.

ALWAYS DISCONNECT ELECTRICAL POWER
BY MOVING PRESSURE SWITCH LEVER TO
THE OFF POSITION AND DRAIN TANK DAILY
OR AFTER EACH USE.

HOW TO PREVENT IT

IT IS NORMAL FOR ELECTRICAL CONTACTS

WITHIN THE MOTOR AND PRESSURE SWITCH

TO SPARK.

IF

ELECTRICAL 

SPARKS

FROM

COMPRESSOR 

COME INTO CONTACT WITH

FLAMMABLE VAPORS, THEY MAY IGNITE,
CAUSING FIRE OR EXPLOSION.

RESTRICTING

ANY OF THE 

COMPRESSOR

VENTILATION OPENINGS 

WILL CAUSE

SERIOUS OVERHEATING AND

COULD CAUSE

FIRE.

UNATTENDED OPERATION 

OF THIS

PRODUCT 

COULD RESULT IN PERSONAL

INJURY OR PROPERTY DAMAGE. TO
REDUCE THE RISK OF FIRE, DO NOT ALLOW
THE COMPRESSOR TO OPERATE
UNATTENDED.

WHAT CAN HAPPEN

HAZARD

Summary of Contents for CPLMC7580V2C

Page 1: ...tions before starting operations Part No D24225 049 2 ESPA OL P GINA 27 FRAN AIS PAGE 53 To learn more about Porter Cable visit our website at http www porter cable com CPLMC7580V2C Copyright 2004 Por...

Page 2: ...State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are G lead from lead based paints G crystalline silica from bricks and cement and other ma...

Page 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Page 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Page 5: ...ARTICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS CONTAIN HARMFUL VAPORS AND...

Page 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Page 7: ...low pressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It...

Page 8: ...essor without first adding oil to the crankcase Serious damage can result from even limited operation unless filled with oil and broken in correctly Make sure to closely follow initial start up proced...

Page 9: ...ion of the Air Compressor Locate the air compressor in a clean dry and well ventilated area Located the air compressor at least 12 away from the wall or other obstructions that will interfere with the...

Page 10: ...product specification found in the front of this manual for the voltage and minimum branch circuit requirements RISK OF ELECTRICAL SHOCK Improper electrical grounding can result in electrical shock T...

Page 11: ...nd main air distribution line to allow for vibration A separate regulator is recommended to control the air pressure Air pressure from the tank is usually to high for individual air driven tools DRAIN...

Page 12: ...air discharge valve Turn knob counter clockwise to open and clockwise to close Drain Valve The drain valve is located at the base of the air tank and is used to drain condensation at the end of each u...

Page 13: ...s See Maintenance How to Use Your Unit How to Stop 1 Set the On Auto Off lever to OFF Check Valve Pressure Release Valve Before Starting Break in Procedure Serious damage may result if the following b...

Page 14: ...o operate a sprayer DO NOT place compressor near the spray area Before Each Start Up 1 Place On Auto Off lever to OFF 2 Close the globe valve 3 Attach hose and accessories NOTE A regulator MUST be ins...

Page 15: ...Before performing any maintenance or repair disconnect power source from the compressor and bleed off all air pressure To Check Safety Valve If the safety valve does not work properly over pressuriza...

Page 16: ...capacity is approximately 40 fluid ounces 1 2 L Overfilling with oil will cause premature compressor failure Do not overfill 5 Replace oil fill plug A and tighten securely To Drain Tank NOTE Operation...

Page 17: ...weight is applied at the midway point 3 When proper belt tension is achieved tighten all four motor mounting screws See Parts manual for torque specifications NOTE Once the engine pulley has been move...

Page 18: ...belt guard 3 Place a straightedge against the outside of the flywheel and the motor drive pulley 4 Measure the distance between the edge of the belt and the straightedge at points A1 and A2 in figure...

Page 19: ...ressure Allow the air compressor to cool To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Turn air compressor off lock out the po...

Page 20: ...This motor has a manual thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting To res...

Page 21: ...slowly bleed from the air tank until tank pressure is approximately 20 psi 6 Drain water from air tank by opening drain valve counter clockwise on bottom of tank Water will condense in the air tank If...

Page 22: ...s where air can be heard escaping Check fittings with soapy water solution DO NOT OVERTIGHTEN Air leaks at fittings Air leaks at pressure switch release valve if equipped Defective pressure switch rel...

Page 23: ...ction Pressure reading on the regulated pressure gauge if equipped drops when an accessory is used It is normal for some pressure drop to occur If there is an excessive amount of pressure drop when th...

Page 24: ...load switch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Loose electr...

Page 25: ...ained Service Technician Belt to tight Check belt tension see Adjusting Belt Tension in the Maintenance section Excessive belt wear Loose belt Tight belt Loose pulley Have checked by a Trained Service...

Page 26: ...and materials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that...