background image

15 - ENG

A02492

STORAGE

Before you store the air compressor,
make sure you do the following:

1.

Review the "Maintenance"
section on the preceding pages
and perform scheduled
maintenance as necessary. 

2.

Set the On/Auto/Off lever to
"OFF" and unplug unit.

3.

Turn the regulator
counterclockwise and set the
outlet pressure to zero.

4.

Remove the air tool or accessory.

5.

Pull ring on safety valve allowing
air to bleed from the tank until
tank pressure is approximately 20
psi. Release safety valve ring.

6.

Drain water from air tank by
opening drain valve on bottom of
tank.

Risk of Bursting.

Water will condense

in the air tank.  If not drained, water
will corrode and weaken the air tank
causing a risk of air tank rupture.

7.

After the water has been drained,
close the drain or drain valve.  

NOTE: 

If drain valve is plugged,

release all air pressure.  The valve can
then be removed, cleaned, then
reinstalled.

8.

Protect the electrical cord and air
hose from damage (such as being
stepped on or run over).  Wind
them loosely around the
compressor handle.

9.

Store the air compressor in a
clean and dry location.

Summary of Contents for C3001

Page 1: ...____________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations Part No A02492 043 1 ESPAÑOL PÁGINA 17 FRANÇAISE PAGE 33 To learn more about Porter Cable visit our website at http www porter cable com MODEL C3001 Copyright 2004 Porter Cable Corpora...

Page 2: ... the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from br...

Page 3: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Page 4: ...ondensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments Excessive vibration can weaken the air tank and cause rupture or explosion The tank is desi...

Page 5: ...rect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Air o...

Page 6: ...othing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate compressor in a stable secure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD ...

Page 7: ... parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Transporting Compressor Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result oil leaks will damage carpet paint or other surfaces in vehicles or trailers ...

Page 8: ...ly restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carryin...

Page 9: ...rounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug see following illustrations 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The out...

Page 10: ... NOT USE 16 OR 18 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with...

Page 11: ...ntrols before operating the unit On Auto Off Switch Turn this switch ON AUTO to provide automatic power to the pressure switch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure S...

Page 12: ...ter 15 minutes close the drain valve The air receiver will fill to cut out pressure and the motor will stop The compressor is now ready for use Cooling System not shown This compressor contains an advanced design cooling system At the heart of this cooling system is an engineered fan It is perfectly normal for this fan to blow air through the vent holes in large amounts You know that the cooling s...

Page 13: ...ockwise to increase pressure When the desired pressure is reached push knob in to lock in place The compressor is ready for use MAINTENANCE Customer Responsibilities Daily or after each use Before each use Check Safety Valve Drain Tank NOTE See Operation section for the location of controls Unit cycles automatically when power is on When performing maintenance you may be exposed to voltage sources...

Page 14: ... release all air pressure The valve can then be removed cleaned the reinstalled Open Drain Valve Closed Drain Valve SERVICE AND ADJUSTMENTS Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconnect electrical supply to the air compressor bleed tank of pressure an...

Page 15: ... is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve ca...

Page 16: ...e purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRA...

Page 17: ...___________________________________ No de série_____________________________________ IMPORTANT Veuillez vous assurer que la personne qui utilise cet outil lit attentivement et comprend ces instructions avant de commencer à utiliser l outil No de pièce A02492 043 1 Pour de plus amples renseignements concernant Porter Cable consultez notre Website à l adresse suivante http www porter cable com PROFE...

Page 18: ...ial ou respirateur homologué MSHA NIOSH bien ajusté lorsque vous utilisez de tels outils Lorsque vous utilisez un outil pneumatique il faut toujours suivre les mesures de sécurité de base afin de réduire le risque de blessures corporelles MESURES DE SÉCURITÉ DÉFINITIONS Indique un danger imminent qui s il n est pas évité causera de graves blessures ou la mort Indique la possibilité d un danger qui...

Page 19: ...er le compresseur à une distance d au moins 20 pieds 6 m de la zone de vaporisation Il peut s avérer nécessaire d utiliser un boyau supplémentaire Entreposer les matières inflammables dans un endroit sécuritaire loin du compresseur Ne jamais placer des objets contre ou sur le compresseur Utiliser le compresseur dans un endroit ouvert à au moins 12 pouces 30 cm de tout mur ou obstruction qui réduit...

Page 20: ...qui risque de causer des dommages à la propriété ou des blessures Porter toujours des lunettes de protection homologuées ANSI Z87 1 avec des écrans latéraux lors de l utilisation du compresseur Ne jamais diriger la buse ou le vaporisateur vers soi vers d autres personnes ou vers des animaux Toujours mettre le compresseur hors fonction et purger la pression du boyau d air et du réservoir avant d en...

Page 21: ...es de mise à la terre Prévention Risque Prévention Risque L air obtenu directement du compresseur ne devrait jamais être utilisé comme source d air pour les être humains Si l air produit par ce compresseur sera utilisé pour la respiration il faut installer des filtres appropriés ainsi que du matériel de sécurité Les filtres en ligne et le matériel de sécurité utilisés avec le compresseur doivent ê...

Page 22: ... après vente autorisé Les pièces mobiles telles que la poulie le volant moteur et la courroie peuvent entraîner des blessures graves si elles entrent en contact avec une partie du corps ou des vêtements En tentant de faire fonctionner le compresseur avec des pièces manquantes ou endommagées ou de réparer le compresseur sans les gardes de protection on s expose aux pièces mobiles ce qui peut entraî...

Page 23: ...out moment Ne tentez jamais d annuler les caractéristiques de sécurité de ce produit Assurez vous qu un extincteur d incendie est disponible dans l aire de travail N utilisez pas l appareil avec des pièces brisées manquantes ou non autorisées AVERTISSEMENT Risque de dommages à la propriété pendant le transport du compresseur Des fuites ou des déversements d huile peuvent se produire et entraîner d...

Page 24: ...le réservoir commence à s accumuler La pression monte et atteint un niveau élevé réglé à l usine avant que le moteur ne s arrête automatiquement protégeant ainsi le réservoir d air d un taux de pression qui excèderait sa capacité La haute pression à laquelle le moteur s arrête s appelle la pression de rupture Circuit de dérivation Le circuit acheminant l électricité du tableau électrique vers la p...

Page 25: ... en fournissant un fil de fuite pour le courant électrique Ce compresseur d air doit être adéquatement mis à la terre Ce compresseur d air portatif est doté d un cordon muni d un fil de mise à la terre et d une fiche appropriée de mise à la terre voir l illustration ci dessous 1 Le cordon fourni avec cet appareil comprend une fiche avec broche de mise à la terre La fiche DOIT être insérée dans une...

Page 26: ... satisfaite ou si l utilisation du compresseur entraîne continuellement une panne de courant il sera peut être nécessaire de brancher le compresseur sur un circuit de 20 ampères Il n est pas nécessaire de remplacer le cordon dans un tel cas Rallonges L utilisation d une rallonge électrique est déconseillée L utilisation d une rallonge produira une chute de tension qui entraînera une perte de puiss...

Page 27: ...cet interrupteur à la position ON AUTO pour alimenter le manostat et à la position OFF pour couper le courant après chaque utilisation Manostat Le manostat démarre automatiquement le moteur lorsque la pression dans le réservoir d air tombe à une valeur inférieure à la pression d amorçage réglée à l usine Il arrête le moteur lorsque la pression dans le réservoir d air atteint la pression de rupture...

Page 28: ...t de vidange Le réservoir d air se remplira jusqu à ce que la pression de rupture soit atteinte et le moteur s arrêtera ensuite Le compresseur d air est maintenant prêt pour l utilisation Système de refroidissement non illustré Le compresseur d air est doté d un système de refroidissement d avant garde Le cœur de ce système est un ventilateur à technologie avancée Il est tout à fait normal que ce ...

Page 29: ...par une autre soupape du même type Avant chaque mise en marche 1 Placez le levier On Auto Off à la position OFF 2 Tirez le bouton du régulateur et tournez le dans le sens contraire des aiguilles d une montre jusqu à ce qu il s arrête Poussez le bouton pour le verrouiller 3 Raccordez le boyau et les accessoires REMARQUE Le boyau ou l accessoire doit être muni d une fiche à connexion rapide si la so...

Page 30: ...atiquement en cycle quand le courant est présent Durant le service vous pourriez être exposé à des sources de tension à l air comprimé ou à des pièces mobiles Avant de faire le service de l unité débranchez ou déconnectez l alimentation électrique au compresseur d air purgez la pression du réservoir et laissez le compresseur d air se refroidir TOUS LES SERVICES D ENTRETIEN NE FIGURANT PAS ICI DOIV...

Page 31: ...la soupape de sûreté 6 Vidangez l eau du réservoir d air en ouvrant le robinet de vidange situé en bas du réservoir Risque d éclatement L eau dans le réservoir d air peut condenser Si le réservoir n est pas vidangé l eau corrodera et affaiblira les parois du réservoir d air causant ainsi un risque d éclatement du réservoir 7 Une fois la vidange de l eau terminée fermez le robinet de vidange REMARQ...

Page 32: ...gallons 227 et 303 litres seront inspectés sur les lieux de leur installation Veuillez communiquer avec le Centre de service après vente agréé de Porter Cable le plus proche offrant le service sur place pour faire les arrangements nécessaires dans un tel cas Tout acheteur qui n est pas satisfait de l intervention du Centre de service après vente agréé de Porter Cable est prié de communiquer direct...

Reviews: