1. 

Hardware Setup 

Connect the RS232 cable between PC & MT360. Any serial port of the PC can be 

used(The software program uses COM1 as default). Make sure the SIM card has been 

inserted in position and the MT360 power is on. 

 

2. 

Software Setup 

The software program ‘MTSMS.exe’ run under the OS : Windows 98/ME/2000/XP. It is 
recommended to run in the display mode ‘1024*768’. 

 

Create a new directory in drive C: as a working directory, for example, “C:\MTSMS”. 
Copy the software program ‘MTSMS.exe’ into this directory. 

 

To execute the ‘MTSMS.exe’ program for the first time, the program will show a setup 

dialog to allow the user to setup the configuration. (Figure as below) 

 

 

‘Mobile number prefix’ field : To check if the mobile number the user entered is a valid 
one. The value “09” means that the mobile number begins with “09”. 
‘Mobile number digits’ field : The digit length of the mobile number. The value “10” 

means that there are 10 digits in the mobile number. 
‘COM port’ field : The serial port which is used to connect your PC to the MT360. 

The user may change these values according to the real situation of your country. 

If the COM port you entered is not ‘1’, then you have to close the program and execute 

again. 

The user may change all these values after the first time setup by clicking the menu 
‘File/System Parameters’ 

Summary of Contents for MT-360

Page 1: ...MT 360 SMS Operation Manual PORTech Communications Inc...

Page 2: ...Index 1 Hardware Setup 1 2 Software Setup 1 3 Operation Guide 2 4 How to send out a short message 3 5 Report File 6 6 Q A 6...

Page 3: ...r the first time the program will show a setup dialog to allow the user to setup the configuration Figure as below Mobile number prefix field To check if the mobile number the user entered is a valid...

Page 4: ...rt messages sent or received and the status of each short message item The Detail Information View shows the activities of the COM port You may toggle these two views in the window menu View Switch to...

Page 5: ...etween MT360 and the PC is OK otherwise you will see the message Timeout No response In that circumstance the serial port might not be assigned correctly or it is occupied by other application program...

Page 6: ...irst type in the message content and mobile number to add into list then click Add button Enter other mobile number then click Add button to add into the mobile number list You can also remove mobile...

Page 7: ...h short message item will be assigned a unique sequence number by the program After this message is sent out by the MT360 GSM module the GSM module will reply a send ID to identify this message The se...

Page 8: ...e will be a file created every day named LOGyyyymmdd TXT SENDMSG subdirectory saves the records for sending out short messages There are 3 files created each day which named SENDyyyymmdd TXT OKyyyymmd...

Page 9: ...ks normally Try to issue the initial commands to MT360 by clicking Test Issue Initial Commands If the Timeout message still appears then check the RS232 cable If the MT360 is used to make a phone call...

Page 10: ...PORTech Communications Inc 150 Shiang Shung N Road Taichung Taiwan 403 R O C Tel 886 4 2305 8000 http www portech com tw...