background image

IS-670  User  manual 

 
 
 

 

12 

 
 

7.5  Other Setting   

Other Setting interface provides SIP Expire Time 

 

 

SIP Expire Time 

Preset  to  be  60;  set  registration  interval;  data  setting  section 
(30-86400). 

CutLine 

Interrupt present broadcast program and restore to idle status 

Submit [key] 

Execute storage and change setting. 

Reset [key] 

Clear input data. 

 

Press [submit] to finish storage setting after changing the data to be adjusted, and select 

the main menu's [SaveChange], to execute storage change setting, the system will restart 

automatically * 

 

 

 

 

 

 

 

Summary of Contents for IS-670

Page 1: ...IS 670 IP POE Wall Mount Speaker User Manual PORTech Communications lnc...

Page 2: ...6 3 SNTP Setting 7 7 SIP Setting 8 7 1 Service Domain broad system server registration setting 8 7 2 Port Setting SIP and RTP port setting 9 7 3 Codec Setting voice format setting 10 7 4 Audio Setting...

Page 3: ...roup broadcast or multipoint broadcast The system composition is simple It is unnecessary to have wiring or purchase an amplifier or player if there is a network environment The system s host and loud...

Page 4: ...III PoE injector non standard 30W X 1 3 PoE Injector connection structure diagram LAN port RJ 45 network port PoE connected to PoE Injector through network cable P D OUT port conducts network connect...

Page 5: ...sername Password defaults username voip Password 1234 data and then click OK to enter the equipment management interface after confirming the password is correct as shown in the following picture Step...

Page 6: ...setting Port Setting SIP and RTP ports setting Code Setting voice format setting Audio Setting loudspeaker volume and sound detection setting Other Setting 3 Update Update firmware updating provides...

Page 7: ...nment status as shown in the following picture Column Introduction Master Show the network environment data of the network port WAN port Type Show current network connection mode IP Show set or gained...

Page 8: ...how preset gateway data Show Show gained or set preset gateway address data DNS Server1 Preset to be 168 95 192 1 show gained or set first DNS server s address data IP or Domain Name can e input DNS S...

Page 9: ...Secondary Server Preset to be 208 184 49 9 the second syn position timing server address Input IP or Domain Name address Time Zone Preset to be GMT 08 00 hh mm timie zone material Sync Time Preset to...

Page 10: ...torage change setting the system will restart automatically Column Introduction Active Preset to be Off put the account into use Put the registration account into use when it is set to be On Register...

Page 11: ...n Introduction SIP Port Preset to be 5060 set SIP port position RTP Port Preset to be 20000 set RTP port position Submit key Execute storage and change setting Reset key Clear input data Press submit...

Page 12: ...3 Preset to be G 723 the third syn position voice format Codec Priority 4 Preset to be G 729 the fourth syn position voice format Codec Priority 5 Preset to be G 726 16 the fifth syn position voice f...

Page 13: ...to idle status for a certain period during which the RTP package of the broadcast system server is not received Submit key Execute storage and change setting Reset key Clear input data Press submit t...

Page 14: ...tting section 30 86400 CutLine Interrupt present broadcast program and restore to idle status Submit key Execute storage and change setting Reset key Clear input data Press submit to finish storage se...

Page 15: ...Location Input file positon or name to be updated or press Browse to select file data version name of the file to be updated Submit key Execute storage and change setting Reset key Clear input data St...

Page 16: ...in File Location has data to be updated if it is confirmed to be correct please press Submit to start updating as shown in the following picture Step 4 enter information prompt picture showing please...

Page 17: ...ng value the system will automatically restart Column Introduction Restore key Remove all change setting data to restore default setting Step 1 click Update Default Setting in the main interface to en...

Page 18: ...m Authority Set system authority Column Introduction New username Input the new user s data Input digits or string New password Input new password Input digits or string Confirmed password Input and c...

Page 19: ...17 10 Save Change Save Changes provides save changes setting and restarts the system automatically Column Introduction Save key Execute storage and change setting 11 Reboot Reboot System interface pro...

Page 20: ...t Step 2 enter the information prompt interface showing that the system is rebooting please wait as shown in the following picture do not pull out power supply equipment at random at the moment Step 3...

Page 21: ...wire Draw it out and change it after the original part is sleeved Please use special outdoor wire material to avoid influence on network quality due to deterioration of wire material The diagram whic...

Page 22: ...nual 20 Step 4 press the attached network joint Step 5 sleeve half the network joint into the front end of the connector body Step 6 screw the rear cover into the rear end of the connector body and sc...

Page 23: ...t half the network joint in the front of the connector body into the speaker network port Step 8 screw the front cover of the connector body into the network port main body clockwise to finish assembl...

Reviews: