Technical Data
Description
Value
Ports
2 x USB, 1 x PLC, 2 x WiFi, 2 x Ethernet, 12 x CT input, 1 x RS485/CAN (not assigned)
Required space
Horizontal pitch 11.5 (1 horizontal pitch equals 17.5-18 mm/0.7 inches)
Current measurement
0.5 A to 600 A (depending on current sensor), maximum cable length 3.0 m
Voltage measurement
100 V to 240 V (AC)
Maximum length of cable to USB port
3.0 m
Energy manager input
24 V (DC)/0.75 A
External power supply (input)
100 V to 240 V (AC)
External power supply (output)
24 V (DC)/18 W
Relay (voltage/load)
Maximum 250 V (AC), maximum 3 A resistive load
Storage temperature range
–40 °C to 70 °C
Operating temperature range
–20 °C to 45 °C (at 10 % to 90 % relative humidity)
Type of item under test
Control unit
Description of device function
Household charge management
Connection to the electricity supply
External mains power supply unit
Installation/overvoltage category
III
Measurement category
III
Degree of contamination
2
Protection rating
IP20
Protection rating to IEC 60529
Rail-mounted device
Protection class
2
Operating conditions
Continuous operation
Overall size of device (width x depth x height)
159.4 mm x 90.2 mm x 73.2 mm
Weight
0.3 kg
External current sensors (accessory, removable part)
ECS1050-L40P (EChun; 50 A input; 33.3 mA output)
TT 100-SD (LEM, 100 A input; 33.33 mA output)
ECS24200-L40G (EChun; 200 A input; 33.3 mA output)
ECS36400-L40R (EChun; 400 A input; 33.3 mA output)
ECS36600-L40N (EChun; 600 A input; 33.3 mA output)
Antenna (accessory, removable part)
HIRO H50284
Transmission frequency bands
2.4 GHz
Transmission power
58.88 mW