- 2 -
7 3 013 6 1- 10 0 Rev. D
2
ROUGHING-IN DIMENSIONS:
NOTE:
Distance from wall to closet flange
centerline must be as listed below:
ARCHIVE 1.6 gpf / 6 Lpf One-Piece Toilet Model 97920-60
ARCHIVE 1.28 gpf / 4.8 Lpf One-Piece Toilet Model 97920-28
C/L OF OUTLET
AND TOILET
MTG BOLTS
30"
(757mm)
18-1/2"
(470mm)
16-1/2"
(419mm)
8-1/2"
(217mm)
12"
(305mm)
14-1/4"
(361mm)
8-1/4"
(206mm)
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
FINISHED WALL
IMPORTANT: Water supply on the wall is required at 3-3/4" or 9" from centerline of the toilet (see rough-in).
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation.
The second suggested position is next to the toilet. Between these two positions, the space for the supply
between wall and toilet is limited to 3-1/4". In this case, check your supply and hose dimensions.
3-3/8"
(86mm)
3-1/4"
(83mm)
FINISHED
FLOOR
14-3/4"
(376mm)
30-3/4"
(781mm)
15"
(380mm)
14"
(356mm)
5-1/2"
(140mm)
SUPPLY AS
REQUIRED
(position 2)
SUPPLY AS
REQUIRED
(position 1)
6"
(152mm)
9"
(229mm)
3-3/4"
(95mm)
3-3/8"
(86mm)
3-1/4"
(83mm)
SUPPLY
AS
REQUIRED
(position 1 or
position 2)
BACK VIEW
29-3/4"
(756mm)
18-1/2"
(470mm)
8"
(203mm)
FINISHED WALL
3/4"
(19mm)
15-1/4"
(388mm)
14-1/4"
(364mm)
6"
(152mm)
13-1/2"
(345mm)
12"
(305mm)
16-1/2"
(419mm)
5-1/2"
(140mm)
30-3/4"
(782mm)
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
IMPORTANT: Water supply on the wall is required at 3-3/4" or 9" from centerline of the toilet (see rough-in).
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation.
The second suggested position is next to the toilet. Between these two positions the space for the supply
between wall and toilet is limited to 3-1/4". In this case, check your supply and hose dimensions.
FINISHED
FLOOR
3-3/4"
(95mm)
9"
(229mm)
14"
(356mm)
IMPORTANT: Water supply on
the wall is required at 3-3/4" or
9" from centerline of the toilet
(see rough-in).
First suggested position is
hidden behind the toilet. The
geometry of the toilet gives
space for this installation.
The second suggested position
is next to the toilet. Between
these two positions, the space
for the supply between wall and
toilet is limited to 3-1/4". In this
case, check your supply and
hose dimensions.
IMPORTANT: Water supply on
the wall is required at 3-3/4" or
9" from centerline of the toilet
(see rough-in).
First suggested position is
hidden behind the toilet. The
geometry of the toilet gives
space for this installation.
The second suggested position
is next to the toilet. Between
these two positions, the space
for the supply between wall and
toilet is limited to 3-1/4". In this
case, check your supply and
hose dimensions.
CHAPEAU 1.6 gpf / 6 Lpf One-Piece Toilet Model 97820-60
CHAPEAU 1.28 gpf / 4.8 Lpf One-Piece Toilet Model 97820-28
IMPORTANT: Water supply on
the wall is required at 3-3/4" or
9" from centerline of the toilet
(see rough-in).
First suggested position is
hidden behind the toilet. The
geometry of the toilet gives
space for this installation.
The second suggested position
is next to the toilet. Between
these two positions the space
for the supply between wall and
toilet is limited to 3-1/4". In this
case, check your supply and
hose dimensions.
PORCHER SOLUTIONS
™
1.6 gpf / 6 Lpf One-Piece Toilet Model 96010-60
PORCHER SOLUTIONS
™
1.28 gpf / 4.8 Lpf One-Piece Toilet Model 96010-28
C/L OF SEAT POST
HOLES 5-1/2
"
(140mm) CENTERS
FINISHED WALL
FINISHED
FLOOR
1"
(23 mm)
1-1/8"
(29 mm)
3-1/2"
(88 mm)
12"
(305 mm)
11-5/8"
(296 mm)
16-1/2"
(419 mm)
30-3/4"
(782 mm)
13-3/4"
(349 mm)
1-1/2"
(163 mm)
28-1/4"
(717 mm)
14-1/2"
(366 mm)
18-1/2"
(470 mm)
IMPORTANT: Water supply on the wall is required at 3-3/4" or 9" from centerline of the toilet (see rough-in).
First suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation.
The second suggested position is next to the toilet. Between these two positions, the space for the supply
between wall and toilet is limited to 3-1/4". In this case, check your supply and hose dimensions.
5-1/2"
(140mm)
SUPPLY AS
REQUIRED
(position 2)
SUPPLY AS
REQUIRED
(position 1)
6"
(152mm)
3-3/4"
(95mm)
14"
(356 mm)
9"
(229mm)