Association Groups: 

Group Number

Maximum Nodes

Description

1

10

Lifeline

2

10

Control Group A

3

10

Control Group B

4

10

Control Group C

5

10

Control Group D

Configuration Parameters 

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further 
enhanced features.

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the 

desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the 
same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Button 1 and 3 pair mode 

In separate mode button 1 works with Group A, button 3 with Group C. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming DOWN. In pair 
button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group A, double click with Group C. 

Size: 1 Byte, Default Value: 1 

Setting

Description

0

Separately

1

In pair without double clicks

2

In pair with double clicks

Parameter 2: Button 2 and 4 pair mode 

In separate mode button 2 works with control group B, button 4 with control group D. Click is ON, Hold is dimming UP, Double click is OFF, Click-Hold is dimming 
DOWN. In pair button B/D are UP/DOWN correspondingly. Click is ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double click with 
Group D. 

Size: 1 Byte, Default Value: 1 

Setting

Description

0

Separately

1

In pair without double clicks

2

In pair with double clicks

Parameter 11: Command to control Group A 

This parameter defines the command to be sent to devices of control group A when the related button is pressed. 

Size: 1 Byte, Default Value: 8 

Setting

Description

0

Disable

1

Switch on/off and Dim (send Basic Set and Switch Multilevel)

2

Switch on/off only (send Basic Set)

3

Switch all

4

Send scenes

5

Send preconfigured scenes

6

Control devices in proximity

7

Control door lock

8

Central scene to gateway (default)

Parameter 12: Command to control Group B 

This parameter defines the command to be sent to devices of control group B when the related button is pressed. 

Size: 1 Byte, Default Value: 8 