The POPP Mold Detector can be mounted in two ways.

1. use the enclosed adhesive tape. Clean the substrate carefully from grease and dirt to achieve optimum strength of the adhesive areas.
2. use the enclosed screws and dowels to fix it to the wall or other surface.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be 

added to an existing wireless network

 to communicate with the

devices of this network. This process is called 

Inclusion

.

Devices can also be removed from a network. This process is called 

Exclusion

. Both processes are initiated by the primary controller of the Z-Wave network. This

controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

Tripple clicking the tamper button includes (adds) the device.
The LED flashes alternately red/green until inclusion is started and green twice after completion.

Exclusion

Tripple clicking the tamper button excludes (removes) the device. 
The LED flashes alternately red/green until inclusion is started and green once after completion for confirmation.

Product Usage

Open the  POPP Mold Detector

To open the POPP Mold Detector, press the lock with your finger and pull the housing cover upwards.

Tamper button

The tamper button is located on the side of the POPP Mold Detector. This button is also used for inclusion and exclusion.

Functionality

Once the device is powered up it will start monitoring the air parameters and warn of mold using the local red and green LED. All air parameters are measured
every 15 minutes. If there is a change by the value set in parameter 1 and 2, it is sent to the central unit. Pushing the button will force an immediate measurement
and the LEDs will indicate the danger of mold

green: no danger of mold in the room

red: danger of mold, on the windows to lower the humidity

The device contains three sensors with the following accuracy measures:

Humidity: +/- 3 % on relative humidity, +/-1 % hysteresis

Temperature: 0 ... 65 °C +/- 1 Kelvin

Dew Point: 0 ... 65 °C +/- 1 Kelvin (calculated from other sensor values)

Besides the measured values the device will issue Z-Wave notifications on moisture (0x10).

Node Information Frame

The Node Information Frame (NIF) is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The
inclusion and exclusion of the device is confirmed by sending out a Node Information Frame. Beside this it may be needed for certain network operations to send
out a Node Information Frame. To issue a NIF execute the following action: Tripple Click the tamper button

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to