background image

3

Step 1 :

 

press 5s to 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

to enter current time setting.

Step 2 :

 

Press to 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 , the hours 

are blinking

, push to  

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 and

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 to adjust the hours.

Step 3 :

 

Press to 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

  , the minutes 

are blinking

, push to  

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 and

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 to adjust the minutes.

Step 4 :

 

Press to 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 to validate and return to the main screen.

4. Use

When the incoming water temperature is higher or equal to the required temperature (setpoint temperature 

+ 1°C), the heat pump will switch to cooling mode. The compressor will stop when the temperature of the 

incoming water is less than or equal to the required temperature (setpoint temperature - 1°C). 

WARNING:

 When the cooling mode switches to heating mode or vice-versa, the heat pump will restart 

after 10 minutes.

Good to know

4.6 

Setting the clock

By default, time programming is inactive. Therefore, it is necessary to activate it and then create time slots.

Here is the manipulation to activate it:

-Appuyez sur 

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

3 seconds pour entrer dans les paramètres à changer. Appuyez sur 

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 et

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

pour choisir les

paramètres.

-Press 

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

 3 seconds to enter the parameters to change. Press 

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

and

 

SET

IN

NO

ROOM

VALUE

OUT

1

2

ON

OFF

TEMP

HUM

h
MIN
%

    F 

AUTO

FAN

h
MIN
%

    F 

 

to choose the settings.

-Go to parameter L2
- Set the value to 1

Once done, you can press «clock» to create your schedules.

4.7 

On / Off programming

Summary of Contents for POOLEX JETLINE SELECTION FI

Page 1: ...Updated INSTALLATION AND USER MANUAL for your heat pump www poolstar fr JETLINE SELECTION FI SILVERLINE FI ...

Page 2: ...ex Push on SET IN NO ROOM VALUE OUT 1 2 ON OFF TEMP HUM h MIN F AUTO FAN h MIN F to change the operating mode The different modes appear in the following order Cooling mode Eco silence Cooling mode Boost Cooling Mode Full Inverter LO H1 nE nE H1 L0 Heating mode Full Inverter Heating mode Boost Heating mode Eco silence Automatic mode 4 3 Operating mode selector 4 4 Temperature setting 4 5 Parameter...

Page 3: ...ode The compressor will stop when the temperature of the incoming water is less than or equal to the required temperature setpoint temperature 1 C WARNING When the cooling mode switches to heating mode or vice versa the heat pump will restart after 10 minutes Good to know 4 6 Setting the clock By default time programming is inactive Therefore it is necessary to activate it and then create time slo...

Page 4: ...he default settings should only be modified by an experienced professional person WARNING Any change to the reserved settings will automatically void the warranty The status values can be checked via the remote control by following these steps Code Name Range Default L0 Water pump working mode 0 ON constantly 1 OFF 60s after compressor off Pump ON 5 min Per L1 min 0 L1 Water pump working period In...

Page 5: ...tus values Step 3 Press SET IN NO ROOM VALUE OUT 1 2 ON OFF TEMP HUM h MIN F AUTO FAN h MIN F to return to the main screen Bon à savoir 4 10 Manufacturer parameter query Status values table in annex VALUE 1 1 ON OFF AUTO FAN VALUE 1 1 ON OFF AUTO FAN 1 1 ON OFF AUTO FAN Step 1 Step 2 Step 3 WARNING This operation is used to assist servicing and future repairs The default settings should only be mo...

Page 6: ...eserve PTF Reserve Pu Water pump switch AH AC fan H speed switch Ad AC fan M speed switch AL AC fan L speed switch dcU DC bus voltage dcC Inverter compressor current A AcU Input voltage AcC Input current HE1 History error code HE2 History error code HE3 History error code HE4 History error code Pr Protocol version Sr Software version 10 Appendices 10 1 Parameter checking To enter the verification ...

Page 7: ...Temperature auxiliary heater start 2 15 C 5 C Adjustable P8 Temperature difference between inlet and outlet protection 2 60 C 10 C Adjustable P9 Bottom plate heater temperature start 9 10 C 0 C Adjustable P10 High fan speed 300 1500 83 Adjustable P11 Mid fan speed 68 Adjustable P12 Low fan speed 52 Adjustable P13 Reserve P14 Reserve P15 Reserve P16 Reserve P17 EEV Maximum opening 50 480 480P Adjus...