2.8.
Alarms
2.8.1.
General description
Any alarm that is activated : - will immediately be displayed on the screen.
Any alarm that is activated :
- automatically and immediately stops chlorination.
Any alarm that is activated :
- can be manually cleared by pressing and holding the bottom key.
Message
displayed
Fault detected
Cause
Checks and solutions
Production anomaly
Low water
Check that the pipe at cell level is completely filled with
water, and the flow is sufficient.
Low salt
-
Check the salt levels in the pool using a recent testing kit.
-
Top up the salt, if necessary, so as to achieve a salt
content of 5 kg/m
3
.
Problem in the
cell
-
Check that the electrical connections to the terminals of
the cell are sufficiently tight and not oxidised.
-
Check that the cell's power cable connector is correctly
connected to the electronics unit.
-
Check that the cell is not scaled.
-
As a last resort, replace the cell.
Problem in the
electronics unit Contact a professional to repair the electronics unit.
Short-circuiting of the
equipment
Problem in the
cell
-
Check that the electrical connections to the terminals of
the cell are sufficiently tight and not oxidised.
-
Check that the cell's power cable is in good condition.
Problem in the
electronics unit Contact a professional to repair the electronics unit.
2.8.2.
Activating/disabling alarm A1
I
Alarm A1 is disabled by default.
1)
Press and hold down the bottom key, until the message is displayed.
2)
Press the bottom key : the message or appears.
3)
With the top key, move to position to activate alarm A1, or to to disable alarm A1.
4)
To confirm, press the bottom key : the display will briefly freeze, then the production setpoint will appear.
Alarm A2 is always activated and cannot be disabled.