Step By Step Instructions
46
52
51
47
48
49
54
53
Attaching the Cover & Bonding Wire
Make sure the webbing continues straight as
it travels from the track to the roll-up tube.
Attach the cover to the roll-up tube using
#10 x 1/2” SS tek screws (23). The first screw on
each end of the tube needs to be 3 inches
from the end of the tube. As the cover rolls up
on the tube, the webbing will be rolling up
over the end casting.
Attach the bond wire from the tail of the
cover to the bonding lug (24) that is
attached to the end casting.
Distribute the slack of the cover evenly
between each screw across the length of
the tube. Secure the cover to the roll-up
tube using #10 x 1/2” SS tek screws (23)
every 2-3 feet.
Closing the Cover
Operate the key switch in the close
position to run the cover over the pool.
Assist the cover as it is being pulled over
the pool by helping unfold it and feed it
into the cover track.
50
Use cable ties (22) to secure the sensor wire
to the motor end of the mechanism to keep
it secure and from getting caught in the
cover or ropes.
Connect the sensor wire to the motor wires
by pressing the wire connections together.
With the cover in the fully closed positon,
measure back 6-1/2 inches from the guide
and place a mark on the webbing.
Installing the Sensor
Thread the sensor into the mounting hole
on the cover side of the guide. The webbing
of the cover will pass over the sensor.
As the excess rope is wrapped around the
rope reel, make sure it goes on straight
without getting crossed with each other.
© Latham Pool Products, Inc. 2016. All rights reserved.
© Latham Pool Products, Inc. 201
9
. All rights reserved.
Numbers in parenthesis refer to parts shown on page 3.
18 of 21