- EN -
17
C A U T I O N
Quartz glass and UVC lamp can break and cause cut injuries.
•
Handle the quartz glass and UVC lamp with care.
The UV-C lamp has to be replaced after approx. 8000 operating hours. Only use UV-C lamps the designation and rat-
ing of which match the information on the type plate.
To replace the UVC lamp open the UVC water housing.
(→ Cleaning the UVC water housing and quartz glass)
How to proceed:
F
1. Remove the quartz glass by carefully turning and pulling it off the UVC lamp.
2. Pull the UVC lamp out of the lamp socket and replace it with a new one.
3. Observe the following: The anti UV silica gel must be inserted into the quartz glass first. Never remove the silica gel.
If there is no silica gel inside the quartz glass, the UV rays may cause damage, see Fig. F.
4. Reassemble the unit in the reverse order.
5. The LED lamps are only for decoration. For replacing the LED lamp it must be replaced and provided by the manu-
facturer, its service agent or similarly qualified persons in order to avoid a hazard.
Wear parts
•
Foam filter
•
Impeller unit
•
UVC lamp, quartz glass and O ring for quartz glass
Storage/Over-wintering
Remove the unit at temperatures below zero degrees centigrade. Thoroughly clean the unit, check for damage and
store immersed in water in a frost-free environment. Do not immerse the plug!
Correct Disposal of this product
N O T E
This marking indicates that this product should not be disposed with other household wastes throughout the
EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return your used device, please use
the return and collection systems or contact the retailer where the product was purchased. They can take this
product for environmental safe recycling.
Guarantee conditions
PfG grants a 2 year guarantee from the date of sale on proven material and manufacturing faults. Wear parts such as
bulbs etc. are exempted from the guarantee. Prerequisite for our guarantee is the presentation of the purchase receipt.
Our guarantee will become null and void if the unit is misused, electrically or mechanically damaged by inappropriate
use and improper repair by non-authorised workshops. Repairs are reserved for workshops authorised by PfG or by
PfG itself. In the case of warranty claims, please return the defective unit or part freight paid to PfG together with a de-
scription of the fault and the purchase receipt. PfG reserves the right to invoice repair costs. PfG is not liable for
transport damage. Any damage must be claimed against the carrier. Further claims of whatever type, especially conse-
quential damage, are excluded. This guarantee does not affect the final customer’s claims against the dealer.