Operation out of the water 

Do not expose the unit to direct sunlight. 

How to proceed: 

 C 

1. Remove the filter housing. 

–  The filter housing is not required for operation out of the water. 

2. Fasten the suction cups to the pump. 

3. Screw the hose connector with O ring onto the outlet and hand tighten. 

4. Screw the hose connector with flat seal and union nut onto the outlet and hand tighten.

5. Set the flow rate (pump delivery rate). 

–  Turning the regulator clockwise: Increases the flow rate. 

–  Turning the regulator counterclockwise: Decreases the flow rate. 

6. Fit one hose to the hose connector at the inlet and one to the hose connector at the outlet, and install the pump on a 

firm surface in a horizontal position. 

–  To prevent air from being taken in, ensure that the pump and the hose to the inlet always remain below the water 

level. 

–  The pump can be fixed to a smooth, clean surface with the suction cups. 

Commissioning/start-up 

 

C A U T I O N

 

Risk of injury due to fast rotating components. 

A temperature monitor switches the unit off automatically in the event of overload and on again once it has 

cooled down. 

Isolate the unit before starting any work. 

N O T E

 

Never allow the pump to run dry. Otherwise the pump will be destroyed. 

Ensure that the pump is always flooded during operation. 

Regularly check the water level. 

Switching on:

 Insert the power plug into the socket. 

–  The unit switches on immediately.

Switching off:

 Disconnect the power plug. 

 

Remedy of faults 

 

Malfunction 

Cause 

Remedy 

The unit does not start up 

No mains voltage 

Check the mains voltage 

Impeller unit blocked 

Clean 

Insufficient fountain height 

Regulator closed too far 

Adjust regulator 

Filter housing or impeller unit soiled, hose 

blocked 

Clean 

Hose defective 

Replace 

Hose kinked 

Route hose in a straight line 

Impeller unit worn 

Replace impeller unit 

Unit switches off after a short running period 

Filter clogged 

Clean 

Water temperature too high 

Adhere to max. permissible water temperature 

(

 Technical Data) 

Downloaded from www.watergardeningdirect.com

Summary of Contents for 57590

Page 1: ...EN Operating instructions PondoCompact 2000 3000 5000 Downloaded from www watergardeningdirect com ...

Page 2: ... 2 A ARS0010 B ARS0004 C ARS0005 Downloaded from www watergardeningdirect com ...

Page 3: ... 3 D ARS0006 Downloaded from www watergardeningdirect com ...

Page 4: ...nect all electrical units in the water from the mains Only operate the unit if no persons are in the water Do not use the unit if electrical cables or housings are damaged A damaged connection cable cannot be replaced Dispose of the unit Safety information Correct electrical installation Electrical installations must meet the national regulations and may only be carried out by a qualified electric...

Page 5: ...arise yourself with the unit Ensure that all work on and with this unit is only carried out in accordance with these instructions Adhere to the safety information for the correct and safe use of the unit Keep these instructions in a safe place Please also hand over the instructions when passing the unit on to a new owner Warnings used in these instructions The warning information is categorised by...

Page 6: ...than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in conjunction with chemicals foodstuff easily flammable or explosive substances Do not connect to the domestic water supply Installation and connection W A R N I N G Death or serious injuries from hazardous electrical voltage due to operation of this unit in a swimming pond Never operate this u...

Page 7: ...ioning start up C A U T I O N Risk of injury due to fast rotating components A temperature monitor switches the unit off automatically in the event of overload and on again once it has cooled down Isolate the unit before starting any work N O T E Never allow the pump to run dry Otherwise the pump will be destroyed Ensure that the pump is always flooded during operation Regularly check the water le...

Page 8: ...as to be removed and put into storage if minus temperatures are expected How to correctly store the unit Thoroughly clean the unit check it for damage and replace any damaged parts Protect electrical connections from moisture and dirt Store the pump submerged and in a frost free environment Protect open plug connections from moisture and dirt Wear parts Impeller unit Disposal N O T E Do not dispos...

Page 9: ...lämpötila HU Típus mért feszültség Teljesítményfelvétel Szállítási tel jesítmény Vízoszlop Merülési mélység Kábelhossz Méretek Súly Vízhőmérséklet PL Typ napięcie znamionowe Pobór mocy Wydajność pompo wania Słup wody Głębokość zanu rzenia Długość kabla Wymiary Ciężar Temperatura wody CZ Typ domezovací napětí Příkon Dopravní výkon Vodní sloupec Hloubka ponoření Délka kabelu Rozměry Hmotnost Teplota...

Page 10: ...ennen pakkasia Mahdollinen vaara sydämen tahdistinta käyttäville henki löille Suojattava suoralta auringonvalolta Lue käyttöohje HU Portömített Vízálló 4 m es mélységig Fagy esetén a készüléket szerelje le A készülék veszélyes lehet szívritmus szabályozóval ren delkező személyekre Óvja közvetlen nap sugárzástól Olvassa el a hasz nálati útmutatót PL Pyłoszczelny Wodosz czelny do 4 m głębokości W ra...

Page 11: ...111 ARS0011 Downloaded from www watergardeningdirect com ...

Page 12: ...37818 10 18 Downloaded from www watergardeningdirect com ...

Reviews:

Related manuals for 57590