Ponovo PAC60Bi User Manual Download Page 15

                                            PAC60Bi (PAC60Ci)/PAV120Bi POWER AMPLIFIER USER MANUAL

 

 

15 

2.3 High Power Current Output   

With high power control button depressed, after several seconds, the high power control button 
light will turn on. By then the current amplifier can improve 20% of output power. This button can 
be used in case there have high current output needed and heavy load applied. 
 

Cautions:

   

1. Generally it’s not necessary to activate the high power output function, because it 

may cause extra heat generated from amplifier. 

2. High power output function must be inactivated as soon as the job was done. Never 

let amplifier stay in high power output state for a long time. 

3. Never activate the high power output function when output terminals are directly short 

connected. 

4. Never activate the high power output function with DC current output. 
5. Never activate or inactivate the high power output function when amplifier is 

producing any output. 

 
 
 
 
 
 
 
 
 

Summary of Contents for PAC60Bi

Page 1: ...PAC60Bi PAC60Ci PAV120Bi AE 1 10 DATE 16 01 2017 This manual is the publication of PONOVO POWER CO LTD Any form of copy should obtain the consent of it The manual represents the technology status at...

Page 2: ...60Ci Amplifier 6 30A RMS 450VA phase 4U 3 phase 380VAC 10 47 63Hz PAV120Bi Amplifier 6 x 120v RMS 60VA phase 4U 3 phase 380VAC 10 47 63Hz Accessories PAP02 Optional accessories Three phase main power...

Page 3: ...keep dry and protect from shaking 5 Generally it s not necessary to depress high power button high power button light should be off also 6 Never operate live signal and load wires with voltage output...

Page 4: ...14 2 1 Basic Principle 14 2 2 Function 14 2 3 High Power Current Output 15 2 4 Front and Rear Panels 16 2 5 Terminal Definition of Rear Panel 18 3 PAV120Bi Voltage Amplifier 19 3 1 Basic Principle 19...

Page 5: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 5 1 Main Technical Performance 1 1 Dimension and Weight 1 1 1 Dimension...

Page 6: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 6 1 1 2 PAC60Ci 1 1 3 PAV120Bi...

Page 7: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 7 1 1 4 PAD24...

Page 8: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 8 1 1 5 PSS01B...

Page 9: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 9 1 1 6 PSS02B or PSS05B...

Page 10: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 10 1 1 7 PAT01...

Page 11: ...e with care during transportation 1 4 Power Input Power supply 380 420V phase phase Type Item PAC60Bi PAC60Ci PAV120Bi Power supply 3 phase 380V 10 50 60Hz 3 phase 380V 10 50 60Hz Supply capacity 2500...

Page 12: ...Current Precision 0 2 0 5A 60A 0 2 0 5A 30A Linearity 0 2 Phase Precision 0 2 Distortion 0 2 Frequency Range DC 5kHz 1dB Step Response 20 s Input output Delay 20 s 1 7 PAV120Bi Voltage Amplifier Outpu...

Page 13: ...C60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 13 1 8 Current Voltage Amplitude Display There are 3 and a half digits of true RMS values displayed for output current voltage with the precision of...

Page 14: ...e of the amplifier is quite low the fan will work at low speed for it s better for prolonging the service life and reducing the operation noise of the fan 2 2 Function 1 The differential input circuit...

Page 15: ...utions 1 Generally it s not necessary to activate the high power output function because it may cause extra heat generated from amplifier 2 High power output function must be inactivated as soon as th...

Page 16: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 16 2 4 Front and Rear Panels PAC60Bi Front and Rear Panels...

Page 17: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 17 PAC60Ci Front and Rear Panels...

Page 18: ...n Overheat alarm signal output Voltage output overload short circuit alarm signal Pause signal output Inverse time limit signal output Control Signal Input Terminal No 1 2 3 4 5 6 Output Mode COM Func...

Page 19: ...ow speed if amplifier temperature is certain low which is benefit for prolonging its service life and reducing working noise 3 2 Function 1 The differential input circuit can reduce the influence of t...

Page 20: ...20 Overheat alarm light on the front panel will turn on 5 3U0 accumulation function Ua Ub and Uc can be added up to form a 3U0 signal to be outputted via Ud channel 6 Two gain options User can accord...

Page 21: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 21 3 3 Front and Rear Panels...

Page 22: ...USER MANUAL 22 3 4 Terminal Definition of Rear Panel Terminal No 0 1 2 3 4 5 6 7 8 9 A B C Function Definition Low pass Filtering 12V Low pass filtering NC Test signal input Test signal GND Test contr...

Page 23: ...test signal of each phase output to the inverse time limit control which should be activated by biggest output current Initial selection for current output with time limit For 1ACT 10A For 5ACT 20A T...

Page 24: ...PAC60Bi PAC60Ci PAV120Bi POWER AMPLIFIER USER MANUAL 24 4 2 PAT01 Front and Rear Panels PAT01 Front Panel PAT01 Rear Panel...

Page 25: ...23 White Blue 2 Voltage amplifier s rectification signal of group I 24 White Blue 3 Amplifier s rectification control of group I 25 White Blue 4 Current amplifier s rectification signal of group II 26...

Page 26: ...t output s test signal 35 White Blue 6 Ia current output s test signal 36 White Blue 7 Ia current output s test signal 37 White Blue 8 Ib current output s test signal 38 White Blue 9 Ib current output...

Page 27: ...anel or operate the remote control to send the pause signal connect current voltage output terminals to corresponding terminals of the tester respectively and then inactivate the pause function and in...

Page 28: ...AV120Bi POWER AMPLIFIER USER MANUAL 28 5 4 Amplifier Off If you want to turn off the amplifier please terminate the simulator signal input pull off all wires between amplifier and loads and turn off t...

Page 29: ...nd high power output running test before delivery The test items include function test linearity load stability total harmonic distortion maximum output power amplitude and frequency characteristic in...

Page 30: ...s are shown as follow 1 Standard Chassis Dimension W D H 600mm 800mm 1600mm 600mm 800mm 1800mm Weight 50kg 60kg Maximum load of caster 300kg 2 PAP 02B Power Control Device Input 3 phase 380V 10 50Hz P...