7.
Maintenance / Service
There are no sophisticated procedures of maintenance necessary for Ponndorf Hose
Pumps.
Nevertheless there have to be made regular inspections in order to avoid any
decrease of capabilities of the pump (e.g. suction capacity / discharge head / flow
rate).
7.1
Changing the pump hose
Remove power from the pump by removing the main fuses before doing
any cleaning / maintenance / assembly operations !
Fig. 7.1.1
Unscrew the flanges on suction and discharge side.
Fig. 7.1.2
Pull connecting sockets out of the end of the hose on
suction and discharge side.
Remove clamping ring from the end of the hose.
Do not wear gloves during these operations because they may
be pulled in!
Fig. 7.1.3
Pull out the defect hose. The extraction of the hose
will be eased by changing the direction of the drive
(pole changing switch) and starting of the motor.
For installation of the new pump hose please consider
chapter 6.4