Now the controller
programming works as below:
Daytime Period
: DT to NT, temperature controlled at (dS ±dF
) ℉
Nighttime Period
: NT to DT, temperature controlled at (nS ±dF
) ℉
Note: The default
dF
(differential value) is 2.0
℉, you can adjust the
dF
value in
Advanced Setting.
3.
Advanced Setting Program
SET sequence:
Time Hour
→
Time Minute
→
dF
→
AL
→
AH
→
Pt
→
CA
→
CF
3.1 Set Current Time
Press & Hold “SET” key 3s--
to enter Advanced Setting (as shown in Figure
6). The upper window number will flicker, press “
▼
” or “
▲
” key to adjust
Time Hour
value.
Press “SET” again
, the lower window number will flicker,
press “
▼
” or “
▲
” key to adjust
Time Minute
value.
Figure 6
3.2 Set Differential Value (dF)
Press “SET” key--
to switch to
dF
Setting (as shown in Figure 7). The lower
window number will flicker, press “
▼
” or “
▲
” key to adjust
dF
value (default
2.0
℉
). Adjustable Range: 1.0-
30.0℉.
Differential value means how far from
the setpoint temperature can drift before turning on heating or cooling.