Operating instructions
After first attaching power to the unit a Power setting is revealed on LED display
(‘
PXXX
’
in red digitals).
“
P
”
is short for
“
power
” and this is how much power is going through to the pump in
watts.
When slow/fast button is pressed the “Flow” or ‘
F
’
setting is revealed
–
there
are 70 flow settings from 030 to 100. Press Slow or Increase to reveal setting, press
again in quick succession to change setting by one level, leave finger on button for
rapid increase/decrease.
Led Protection Mode
To protect the LED Screen after 30 seconds without touch the LED changes from micro
bright to the screen saver mode; Press any button to return to normal.
Memory Function
Control Panel stores the last setting used. It will retune to this setting when re-
connected.
Fault Code Description
Using intelligent circuitry, the control panel will sense any pump malfunction and will
return an error code to the LCD display for viewing. We include suggested remedies.
Er01:
Abnormal working current
;
Check if pump short of voltage or controller broken
Er02:
Controller over-heating;
Check if Controller positioned in sun or high temperature
Er03:
Pump idling
;
Check the Pump works dry.
Er04:
The impeller stopped turning;
Clean Pump & Impellor until impellor turns freely.
Er05:
Abnormal running voltage;
Check input supply voltage.
Auto-Off Function
Should your pond or water reservoir become too shallow for the pump to operate
correctly sensors built into the pump will detect this. After a period of two minutes
unless this situation is rectified, the pump will switch off automatically to prevent
motor damage.
Methods of Use
Your pump must always be immersed in water before it is switched on. The pump can
be submersed or run externally. In
“
dry
”
use water flow should be connected to the
water intake hose. As the name implies an external pump sits outside of the pond in a
dry location.