PondMAX 22PV030 Instruction Manual Download Page 3

WAT E R G A R D E N I N G   T O   T H E   M A X

POND & FOUNTAIN 

PUMPS

BENEFITS INCLUDE

• PondMax Pond & Fountain Pumps are suitable for 

use in many different applications including ponds, 
fountains and other water feature applications. The 
pumps can be used in either submersible or in-line 
applications. 

• Your pump has a single moving part (an impeller), 

enabling easy cleaning and maintenance.

• The motor is totally encapsulated in epoxy resin, 

ensuring safe operation under water.

• Your pump is magnetically driven and relies on water 

to cool and lubricate it.  Therefore no harmful oil or 
grease lubrication is required.

• PondMax Pond & Fountain Pumps are continuous 

rated, therefore are designed to operate 24/7. 

• An optional fountain kit can be purchased and fitted 

to the models PV250 – PV550 pumps. When using 
with a fountain kit, it is strongly recommended to 
purchase a optional PondMAX SP250 Submersible 
Prefilter. This assists in straining the particles in the 
water, to assist the fountain nozzles from becoming 
blocked up with debris. See your retailer for 
availability or more information.  

• Any damage to the equipment or unmerited operation 

will bring dangers to the surrounding precincts. So if 
there is any damage of the equipment, it must not be 
used. The equipment should be placed out of reach of 
children.

• For your own safety, disconnect from the power supply 

before any maintenance of any equipment is attempted 
on the tank or water body. Always unplug the pump 
from the power supply when not in use. Never pull the 
cable to disconnect the plug from the power supply - 
grasp the plug and pull to disconnect. If required, have 
a qualified electrician install a weatherproof power 
supply point near to the pond or water-feature (within 
the cable length of the appliance).

• Be sure the equipment is submerged completely in the 

water. The depth should not be greater than 6.5Ft.

• Do not operate the pump if the appliance or any 

components of the system, such as the power cable, 
have been damaged. Check appliance for defects 
regularly. 

• For safety, plug the pump into an electrical outlet with 

a (GCFI) Ground Fault Circuit Interrupter. 

• To avoid an electric shock, do not attach the plug to the 

power supply socket with wet hands. The drip loop 
method should be used to prevent water from traveling 
down the cable and onto the plug or power supply. 
If the plug does get wet, do not unplug the cable. 
Disconnect the circuit breaker that supplies power to 
the power supply point. Then unplug and examine the 
plug and power supply point for presence of water. If 
the power point has become wet, you should consult an 
electrician before using the power point again. 

• Do not install or store the appliance where it will be 

exposed to extreme hot or cold temperatures. Do not 
use in water above 95°F.

• Do not cut the cable as this will result in voiding your 

warranty.

• Care should be taken to arrange the power cable so 

that it cannot be accidentally tripped over or pulled. 

• Do not attempt to repair the electrical appliance 

yourself. Return to an authorized service centre or 
place of purchase if a fault occurs, (regular 
maintenance is not considered repair and is required by 
user). 

IMPORTANT SAFEGUARDS

Correct  and  safe  use  of  the  system  requires  strict  compliance  with  the  safety  instructions.  For 
safety reasons, persons less than 16 years of age that are not familiar with these instructions should 
not use this equipment.

PMAX PV250_350_550 Pump Instructions.indd   3

28/9/16   9:50 am

Summary of Contents for 22PV030

Page 1: ...ERSION SEPT 2016 22PV030 PV250 22PV050 PV350 22PV075 PV550 POND FOUNTAIN PUMP INSTRUCTION MANUAL 888 868 1185 info pondmax com www pondmax com PMAX PV250_350_550 Pump Instructions indd 1 28 9 16 9 50 am ...

Page 2: ...SE READ THESE INSTRUCTIONS CAREFULLY AND BECOME FAMILIAR WITH THE UNIT PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE SUBJECT TO VARIATION ACCORDING TO LOAD SOLD SEPARATELY DESIGN HIGHLIGHTS The PondMax Pond Fountain Pumps have been manufactured to provide you with the best quality pumps for your water feature Visit our website to view our range of pond filtration outdoor unde...

Page 3: ...ed electrician install a weatherproof power supply point near to the pond or water feature within the cable length of the appliance Be sure the equipment is submerged completely in the water The depth should not be greater than 6 5Ft Do not operate the pump if the appliance or any components of the system such as the power cable have been damaged Check appliance for defects regularly For safety pl...

Page 4: ...For best results consult with an expert to make sure you use the correct size of tubing for your pump flow and application Select the outlet hosetail and screw into the top of the pump Now connect the tubing to the hosetail Remember to use stainless steel hose clamps to fasten the hose EXTERNAL USE When installed outside the pond or fountain follow proceedure as outlined below For best results in ...

Page 5: ... of 1 2 Nipple Now on the top of the Dual Control T Piece 2 connect the Threaded Reducing 4 on Now extend Telescopic Riser with Threaded Locking Nut 10 to the desired height then secure onto the top 1 thread of the Threaded Reducing with the threaded locking nut provided Align Telescopic Riser with Threaded Locking Nut 10 vertically 7 Fine Daisy Fountain Nozzle 8 Coarse Daisy Fountain Nozzle 9 Bel...

Page 6: ...er Reinstall the shaft and then carefully slide the impeller onto the shaft The impeller will pull itself in by magnetic force this is normal Take care not to pinch your fingers With the impeller in the correct position carefully place the impeller cover back on and then rotate clockwise to lock into position Making sure the ceramic shaft is located properly in the impeller cover center hole Then ...

Page 7: ...udge Clean the sponges and filters Impeller is blocked with sludge or lime scale build up Clean the impeller as per the instructions Submerse the equipment underwater then plug in Refill if necessary Blocked impeller chamber or ceramic shaft is broken Clean the impeller Check for wear Replace if necessary WATER PUMP IS NOISY Blockage in pump Clear the blockage Impeller shaft worn out Replace impel...

Page 8: ... this warranty This warranty is in lieu of all other express warranties which now or hereafter might otherwise arise with respect to this product Any and all limited warranties including the warranties of merchantability and fitness for particular purpose shall have no greater duration than the duration period of the express written warranty applicable to this product and shall terminate automatic...

Reviews: