background image

 

12 

 

 

0901712

 

Handling 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                 

 

 

 

 

 

 On / Off 

– Button: Switches the device on or off. 

 If the device switched off 

it can be started by pressing the „on“ button. 

 If the device is on, this button has to be pressed for 1 sec to switch it off.  
 The auto-off function is regularly on, shown by displaying 

„Auto-off“. 

 In this case the measurement device will switched off automatically after 
 10 minutes.  
 By  pressing the button      this function can be switched off . 

 
REF Activates reference measurement function. At the right upper sight will 
        shown the reference value. 
 
dBm Selection indicate value dBm or Watt 
  W 
 
λ      Switches between the possible wavelengths: 800 nm - 1700 nm. The  
        selected wavelength is shown in the display. 
 

Selection of 
wavelength 

Switch between 
dBm and Watt

 

On / Off button 

Displays the 
wavelength 

Show 
modulation or 
reference value 

Optical input 
FC/PC 

Power supply 
connection 

Displays mains 
operation 

 

State of battery 

Displays if 

„auto 

off“ is activated 

Reference 
measurement

 

Summary of Contents for OME 200

Page 1: ...Optisches Messger t Optical measurement device OME 200 Bedienungsanleitung Operating manual 0901745 V2...

Page 2: ...bschaltfunktion Referenzmessung M glichkeit des Netzbetriebes Netzteil im Lieferumfang enthalten Lieferumfang 1 x OME 200 Messger t 1 x Aufbewahrungstasche mit Tragegurt 1 x Bedienungsanleitung 3 x Ba...

Page 3: ...s nicht den optischen Wandler ffnen um Verschmutzung oder Zerkratzen des SC APC Steckers zu vermeiden 2 Der optische Eingangspegel sollte nicht h her als 30 dBm sein andernfalls wird das optische Modu...

Page 4: ...Es k nnen Batterien oder Akkus 3 x Mignon AA verwendet werden Die Aufladung der Akkus muss in einem externen Ladeger t vorgenommen werden Dauer des Batteriebetrieb ca 140 Stunden Batteriefach Abdeckun...

Page 5: ...10 Minuten aus Um dies zu deaktivieren gen gt ein kurzer Tastendruck auf REF Referenzmessung aktivieren Rechts oben wird der gespeicherte Referenzwert angezeigt dBm Auswahl des Me werts zwischen dBm o...

Page 6: ...gte Ende des PON Kerbe des Steckers beachten 5 Schalten Sie das optische Messger t ein bitte die automatische Abschaltung beachten und gegebenenfalls deaktivieren siehe Seite 5 6 Im Display werden die...

Page 7: ...7 OME 100 7 dBm Ausgangsleistung OSF 800 10 dB D mpfung OME 200 18 dBm Eingangsleistung...

Page 8: ...8 Notizen...

Page 9: ...cise measurement range Mains operation Power supply included Included parts 1 x OME 200 measurement device 1 x Bag with shoulder strap 1 x Manual 3 x Batteries Type Mignon AA 1 x Cleaning swabs set 25...

Page 10: ...it please do not open the optical adapter converter to avoid pollution and scratching of the SC APC connector 2 Input of optical power should not be higher than 30 dBm otherwise the optical modules wi...

Page 11: ...on Please pay attention It s possible to use battery or accu 3 x Mignon AA The accu charge process must be done in an external charging device Battery operation approx 140 hours Battery case Cover Fla...

Page 12: ...ing the button this function can be switched off REF Activates reference measurement function At the right upper sight will shown the reference value dBm Selection indicate value dBm or Watt W Switche...

Page 13: ...PON you want to measure Pay attention to the notch 5 Switch the optical measuremrent device on pay attention to the switch off automatic and deactivate this if necessary page 11 6 At the display is t...

Page 14: ...14 OME 100 7 dBm Output power OSF 800 10 dB loss OME 200 18 dBm Input power...

Page 15: ...15 Notes...

Page 16: ...rungen vorbehalten Subject to change without prior notice Copyright Polytron Vertrieb GmbH Type OME 200 Artikel Nummer Article number 9245492 Wellenl nge Wave length 800 1700 nm Detektor Typ Detector...

Reviews: