LAB704R, Issue 10, May 2016

 

 

Wiring Instructions: 

 

It  is  recommended  that  the  fans  are  connected,  with  double  pole  isolation  (3mm  minimum  contact 
separation)  provided  before  the  room  light  switch  and  suitably  fused,  in  accordance  with  the  latest 
edition of the IEE Wiring Regulations. 

 

Wall mounted fans for fixed wiring should be connected to the power supply through a cable with solid 
conductors of 1.0mm² or 1.5mm². 

NOT FOR USE WITHIN A SHOWER CUBICLE OR WITHIN ZONES 1 & 2 

WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK 

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN 

THIS APPLIANCE MUST BE EARTHED 

SL = 230Vac Switched Live 

L = 230Vac Permanent Live 

N = Neutral 

 

 

KIT2S-RS Manual Speed Selector Switch (ANC848A)   

 

 

 

 

                                          

KIT2S-PC Pull Cord Speed Selector    

 

 

 

 

 

 

 

When the speed selector switch or pull cord 

is manually activated the fan will “boost” up to either S2 

or S3 speed depending on how the switch or pull cord is wired.  

 

 

 

Isolator Switch 

Manual speed selector switch/built in 
pull cord 

Wire switch 
output to either S2 
or S3 NOT BOTH

.  

Link wire 