Wiring Instructions:
It is recommended that the fans are connected, with double pole isolation (3mm minimum contact
separation) provided before the room light switch and suitably fused, in accordance with the latest
edition of the IEE Wiring Regulations.
Wall mounted fans for fixed wiring should be connected to the power supply through a cable with solid
conductors of 1.0mm² or 1.5mm².
NOT FOR USE WITHIN A SHOWER CUBICLE OR WITHIN ZONES 1 & 2
WARNING: ISOLATE ELECTRICITY SUPPLY BEFORE STARTING WORK
IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN
THIS APPLIANCE MUST BE EARTHED
SL = 230Vac Switched Live
L = 230Vac Permanent Live
N = Neutral
KIT2S-RS Manual Speed Selector Switch (ANC848A)
KIT2S-PC Pull Cord Speed Selector
When the speed selector switch or pull cord
is manually activated the fan will “boost” up to either S2
or S3 speed depending on how the switch or pull cord is wired.
Isolator Switch
Manual speed selector switch/built in
pull cord
Wire switch
output to either S2
or S3 NOT BOTH
.
Link wire