Email:
7
Website:
www.polypipe.com/ventilation
LAB1191R, Issue 1, May 2015
Select any of U1 to U4
U1 to U4
U1 to U4
U1 to U4 as this allows each AMIE controller to store up to 4 user defined
programmes in its memory. With U1 to U4 blinking press the programme key (((( )
)
)
) to
access programme settings- The program creation will always start with the day 1
1
1
1
(Monday).
Once you have pressed the (((( )
)
)
) key, the following display will appear.
Adjust the hour of the first step of the programme with ((((----)
)
)
) or (+).
(+).
(+).
(+).
Press (OK)
(OK)
(OK)
(OK) to validate and move to the following step.
The pictogram will blink meaning that you can toggle between
and
with ((((----)
)
)
) or (+)
(+)
(+)
(+),
Choose and press (OK)
(OK)
(OK)
(OK) to validate and then adjust the hour of this step with ((((----)
)
)
) or (+)
(+)
(+)
(+),
Press (OK)
(OK)
(OK)
(OK) to validate and move to the next step. If you selected the
option you will
automatically be required to select an addition heat recovery period
with ((((----)
)
)
) or (+)
(+)
(+)
(+).
Select the start time of the next period, with ((((----)
)
)
) or (+),
(+),
(+),
(+), and press (OK)
(OK)
(OK)
(OK) and move to the
next step.
The pictogram will blink gain meaning that you can toggle between
and
with ((((----)
)
)
) or (+)
(+)
(+)
(+),
Should you wish to have a further bypass and heat recovery period during the day select
the
option and press (OK)
(OK)
(OK)
(OK) to validate. Then follow previous steps.