United States Safety Construction Details

:

o All connections are indoor only.

o No direct connections to public networks.

o Unit is intended for RESTRICTED ACCESS

LOCATION.

o Unit is to be installed in accordance with the

National Electrical Code.

o The branch circuit overcurrent protection shall

be rated 20 A for the AC system.

o This equipment has a maximum operating

ambient of 40°C, the ambient temperature in

the rack shall not exceed this temperature

CE Mark R&TTE Directive

Polycom Inc., declares that the Polycom KWS 8000 is

in conformity with the following relevant harmonized

standards:

EN 60950-1:2006

EN 55022:2006

EN 55024:1998, A1:2002, A2:2003

Following the provisions of the Council Directive

1999/CE on radio and telecommunication terminal

equipment and the recognition of its conformity.

This KIRK product has been marked with

the CE mark. This mark indicates

compliance with EEC Directives 89/336/EEC,

73/23/EEC 1999/5/EC. A full copy of the

Declaration of Conformity can be obtained

from Polycom Ltd, 270 Bath Road, Slough,

Berkshire, SL1 4DX, UK.

The WEEE Marking on this equipment

indicates that the product must not be

disposed of with unsorted waste, but must

Summary of Contents for KIRK 8000

Page 1: ...Polycom KIRK Wireless Server 8000 Installation Guide ...

Page 2: ...Polycom Inc Information contained herein is subject to change without notice and does not represent commitment of any type on the part of Polycom Inc Polycom and Accord are registered trademarks of Polycom Inc Notice While reasonable effort was made to ensure that the information in this document was complete and accurate at the time of printing Polycom Inc cannot assume responsibility for any err...

Page 3: ...ing the KWS 8000 on a Flat Surface 1 4 Installing the KWS8000 on a Wall 1 5 Connecting the KWS8000 Cables 1 6 Installing Interface Cards and CPU Cards 1 9 Replacing Components Component Replacement 2 1 Component Replacement Precautions 2 2 Regulatory Notices International Regulatory and Product Information 3 1 Important Safety Instructions and Product Information 3 4 ...

Page 4: ...00 on a stable flat surface in the selected location and inspect the package for any damage and report it to the reseller or distributor immediately Important Please review all the safety instructions for important safety and regulatory information Specifications Table 1 1 Physical dimensions Physical dimensions Height 177mm Width 422 mm Depth 328 mm Weight 5 34 kg Excl power supply Table 1 2 Powe...

Page 5: ... KWS8000 unit It should be situated in a clean dry dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Place it near a grounded power outlet Installing the KWS8000 in a Rack Before you start installation take notice of the following safety precautions Table 1 3 Power consumption Power consumption Typical AC Power Consumption 90 Wa...

Page 6: ...ep the rack s trays and board s closed when not servicing to maintain proper cooling The rack ambient temperature may rise beyond room ambient temperature in a multi unit assembly measures must be taken to ensure the KWS8000 ambient temperature does not exceed the maximum operating ambient temperature of 40 Celsius To ensure ventilation always leave 2 3 U between the KWS8000 units any other units ...

Page 7: ...e following safety precautions Flat Surface Mounting Safety Precautions Ensure the surface can support the weight of the unit Never install the KWS8000 on the floor Never place anything except ONE additional KWS8000 unit on top of the KWS8000 The top plate must be free to allow sufficient cooling To Install the KWS 8000 on a Flat Surface 1 Remove the KWS8000 from its package ...

Page 8: ...tions Wall Mounting Safety Precautions Ensure the wall quality is good enough for holding the unit Avoid high porous surfaces joints and similar Never use countersunk screws Leave at least 10 centimeter of free air above the unit for ventilation To Install the KWS8000 Using the Wall Hanger For free hanging installations you use the wall hanger 1 Find a suitable spot on an even closed textured surf...

Page 9: ...S8000 into the wall hanger Connecting the KWS8000 Cables When the KWS8000 has been mounted the cables can be connected Cable Safety Precautions Before you connect the cables ensure to take the following electrical safety precautions Always use an earthed socket for power Use a power cord with protective earth PE connection suitable for the country where it is being used and with the appropriate lo...

Page 10: ... from the KWS8000 The AC adapters must never be hanging by their own weight in the AC mains connector or the output connector To Connect Power Cables The KWS8000 has four power plugs on the back panel behind the sliding doors System Power Backup System Power Primary 4 BIF Power Backup 4 BIF Power Primary Figure 1 4 KWS 8000 Power plugs System Power 4 RFP Power 0V 19V Backup Primary Backup Primary ...

Page 11: ...rest does not have to be done in any particular order 5 When powering down the unit ALL power connectors must be unplugged to ensure the unit is completely powered off Two AC power adapters may be kept in the room behind the sliding doors at the rear of the KWS8000 Installation must be done prior to connecting the adapters to AC mains Table 1 5 Cable plugs overview Nbr BIF Card s Redun dancy SYS P...

Page 12: ...ore you install an interface or a CPU card ensure to take the following precautions Safety Precautions Cards contain static sensitive circuitry and may be destroyed or damaged by electrostatic discharge ESD Make sure you re using proper ESD equipment to prevent damage to the system Fill all empty slots with blanking front plates to close the front To Install Interface Cards 1 With two hands gently...

Page 13: ...nnecting Interface Cables on page 1 11 To Install CPU Cards 1 Ensure that the KWS8000 is powered off completely 2 With two hands gently slide the card into the unit Give the card a gentle push on the last centimeter so that it enters the backplane connector properly Avoid pushing on the front connectors push only on the plastic parts at the top and bottom ...

Page 14: ...ect the power and reboot the unit Connecting Interface Cables The front interface of the KWS8000 is provided with connectors for the different interfaces provided Please see the KWS8000 User Guide for the actual pin out of the different connectors The cables can be harnessed in two ways as shown in the following figures depending on the installation requirements ...

Page 15: ...Polycom KIRK Wireless Server 8000 Installation Guide 1 12 Figure 1 8 Harnessing cables to the back and out ...

Page 16: ...lation 1 13 Figure 1 9 Harnessing cables to the side and out Regardless of which way is used for harnessing you must guide the cables through the opening in the plastic front This ensures safe retention of the cable ...

Page 17: ...ents can be replaced while the system is up Component Replacement The following components are hot swappable Interface cards AC adapters The following require a power down of the system Backplane CPU card Before replacing any components take notice of the component replacement precautions ...

Page 18: ...arthed 2 Unplug all interface cables on the card that needs to be replaced noticing which goes where 3 Remove the cables from the opening in the plastic front 4 With two hands gently pull out the card 5 Gently slide the new card into the unit Give it gentle push on the last centimeter so that it enters the backplane connector properly Avoid pushing on the front connectors push only on the plastic ...

Page 19: ...ed for repair or be replaced with a new one If a new chassis is to be installed you can move the cards from the faulty chassis to the new one To Replace an AC Adapter Check to see if unit has a backup supply attached If yes then unplug the faulty one and replace it with a new one If the unit has no backup supply plug the new AC adapter into the appropriate backup plug and remove the faulty AC adap...

Page 20: ... equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manuals may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or her own expense Part 68 Network Registr...

Page 21: ...ient temperature in the rack shall not exceed this temperature CE Mark R TTE Directive Polycom Inc declares that the Polycom KWS 8000 is in conformity with the following relevant harmonized standards EN 60950 1 2006 EN 55022 2006 EN 55024 1998 A1 2002 A2 2003 Following the provisions of the Council Directive 1999 CE on radio and telecommunication terminal equipment and the recognition of its confo...

Page 22: ...ilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations Repairs to certified equipment malfunctions may give the telecommunications company causes to request the user to disconnect the equipment Users ...

Page 23: ...through cabinet slots as they may touch dangerous voltage points or short out parts that could result in fire electrical shock or injury Never spill liquid of any kind into this product 8 To reduce the risk of electrical shock or burns do not disassemble this product Opening or removing covers may expose you to dangerous voltages dangerous electrical current or other risks Incorrect reassemble can...

Page 24: ...ot install the unit in conditions where there is a danger of electrically ignited explosions Exposure to sunlight heat and moisture Do not expose the unit to direct sunlight for long periods Keep away from excessive heat and moisture Spare parts and accessories Use only approved spare parts and accessories The operation of non approved parts cannot be guaranteed and may even cause damage RF compli...

Page 25: ...OM PRODUCTS LIMITED WARRANTY Polycom warrants to the end user Customer that the product will be free from defects in workmanship and materials under normal use and service for one year or such longer period as Polycom may announce publicly from time to time for particular products from the date of purchase from Polycom or its authorized reseller Polycom s sole obligation under this express warrant...

Page 26: ... OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH DESCRIPTION AND NON INFRINGEMENT ALL OF WHICH ARE EXPRESSLY DISCLAIMED POLYCOM NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR...

Page 27: ... the International Sale of Goods is hereby excluded in its entirety from application to this Limited Warranty and Limitation of Liability END USER LICENSE AGREEMENT FOR POLYCOM SOFTWARE IMPORTANT READ CAREFULLY BEFORE USING THE SOFTWARE PRODUCT This End User License Agreement Agreement is a legal agreement between you either an individual or a single entity and Polycom B V for the POLYCOM SOFTWARE...

Page 28: ...DUCT must be marked with the proprietary notices provided on the original SOFTWARE PRODUCT You may not reproduce the supporting documentation accompanying the SOFTWARE PRODUCT 2 3 Modifications You may not modify translate or create derivative works of the SOFTWARE PRODUCT 2 4 Proprietary Notices You may not remove or obscure any proprietary notices on or in the SOFTWARE PRODUCT or the supporting ...

Page 29: ...s and conditions of this Agreement With respect to technical information you provide to POLYCOM as part of the SUPPORT SERVICES POLYCOM may use such information for its business purposes including for product support and development POLYCOM will not utilize such technical information in a form that personally identifies you 4 TERMINATION Without prejudice to any other rights POLYCOM may terminate ...

Page 30: ... PURCHASE PRICE PAID AT POLYCOM S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES TERMS OR CONDITIONS OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE SATISFACTORY QUALITY CORRESPONDENCE WITH...

Page 31: ...country to which the U S has embargoed goods or ii to anyone on the U S Treasury Department s list of Specially Designated Nationals or the U S Commerce Department s Table of Denial Orders By downloading or using the SOFTWARE PRODUCT you are agreeing to the foregoing and you are representing and warranting that you are not located in under the control of or a national or resident of any such count...

Page 32: ...nce display or disclosure of the SOFTWARE PRODUCT programs and or documentation by the U S Government or any of its agencies shall be governed solely by the terms of this Agreement and shall be prohibited except to the extent expressly permitted by the terms of this Agreement Any technical data provided that is not covered by the above provisions is deemed to be technical data commercial items pur...

Page 33: ...n and Configuration Guide 11 Tables Table 1 1 Physical dimensions 1 1 Table 1 2 Power supply 1 1 Table 1 3 Power consumption 1 2 Table 1 4 Environment 1 2 Table 1 5 Cable plugs overview 1 8 Table A 1 RJ45 cable wiring A 1 ...

Page 34: ...he kWS8000 into the wall hanger 1 6 Figure 1 4 KWS 8000 Power plugs 1 7 Figure 1 5 Storing room for two AC power adapters 1 9 Figure 1 6 Installing Interface cards 1 10 Figure 1 7 Installing CPU card 1 11 Figure 1 8 Harnessing cables to the back and out 1 12 Figure 1 9 Harnessing cables to the side and out 1 13 ...

Page 35: ...ion 1 11 Interface card installation 1 9 P Physical dimensions 1 1 Power cables connecting 1 6 Power consumption 1 1 Power supply 1 1 R Rack installation 1 3 S Safety Cables 1 6 Flat surface installation 1 4 Interface and CPU cards 1 9 Rack mounting 1 3 Wall mounting 1 4 Specifications 1 1 W Wall hanger installation 1 5 ...

Page 36: ...o plug and socket pins of the RJ45 cable Table A 1 RJ45 cable wiring Pin Pair Wiring Connector 1 Connector 2 Connector 3 Connector 4 1 2 tip 1 5 9 13 2 2 ring 1 5 9 13 3 3 tip 2 6 10 14 4 1 ring 0 4 8 12 5 1 tip 0 4 8 12 6 3 ring 2 6 10 14 7 4 tip 2 7 11 15 8 4 ring 3 7 11 15 ...

Page 37: ......

Page 38: ...14184630 Hd 1 Rasmussens Bogtrykkeri Ringkøbing ...

Reviews: