background image

 

 

12 

 
During an H.323 call the network connection was removed and reconnected after a 
specific time: 
 
The normal 5 seconds test could not be checked as the calls dropped immediately, 
this  is  very  unusual  after  such  a  short  period,  as  calls  with  other  manufacturers‘ 
products 

typically 

reconnect 

after 

up 

to 

30 

seconds 

network 

disconnection/reconnection. 

 
 

Time to Connect  
 

H.323 

 

All speeds

 

Approx. 3 seconds 

 

 
Connectivity with Other Machines

 (models listed with comments) 

   

 

 

 

 

 

 

H.323 

 
Successful  connections  were  made  in  each  direction  with  the  following  CODEC

s

where the systems supported H.239, presentation material was also shared.  
   

 

 

 
 
 
 

 
 
 
 

C
o
n
n
e
c
t

 


P

 
 

H
  

 

In calls between the HDX4500 and Tandberg Edge 95 low resolution CIF was 
transmitted by the Tandberg and SIF was transmitted by the HDX4500. 

 
 

In calls between the HDX4500 and Tandberg 6000 MXP the HDX4500 transmitted 
4CIF. 

CODEC 
Model  and  Software 
Version 

Call 
Bandwidth 

Resolution 
Transmitted by 
the HDX 4500 

Resolution 
Received by  
the HDX 4500 

Polycom PVX 
S/W   8.0  

1.5 Mbit/s 

352 x 288 

320 x 240 

Polycom® VSX7000 
S/W   9.0.5.1 

2 Mbit/s 

352 x 288 

352 x 288 

Tandberg Edge 95 
S/W   F9.0 PAL 

2 Mbit/s 

352 x 240 

352 x 288 

Tandberg 6000 MXP 
S/W   F9.0 PAL 

2 Mbit/s 

704 x 576 

720p 

Tandberg C40 
S/W   TC4.0.1 

2 Mbit/s 

1080p 

720p 

Tandberg C60 
S/W   TC3.1.1 

2 Mbit/s 

1080p 

720p 

Polycom HDX 9002 
S/W   2.6.0 

2 Mbit/s 

720p 

720p 

Lifesize Team 
S/W   4.7.10 

2 Mbit/s 
 

720p 

720p 

Lifesize Room 200 
S/W   4.7.0 

2 Mbit/s 
 

720p 

720p 

Summary of Contents for HDX 4500

Page 1: ...04 TEST RESULTS FOR POLYCOM HDX 4500 Manufacturer Polycom Model HDX 4500 Software Version 3 0 3 14451 Optional Features and 1080p Resolution Modifications Date of Test 14th 18th November 2011 System...

Page 2: ...ii HD Camera Control Panel...

Page 3: ...ROCEDURE 2 C HARDWARE DESCRIPTION 2 D SYSTEM OPERATION 7 E VIDEO TESTS SUMMARY 11 F AUDIO TESTS SUMMARY 11 G DATA TESTS 11 H CONNECTIVITY 11 Appendix 1 Detailed Physical Information 14 Appendix 2 Deta...

Page 4: ...definition videoconferencing system which supports variable resolutions up to a maximum of 1920 x 1080 pixels 1080p at 30fps or 1280 x 720 pixels 720p at 60fps A single integrated unit comprising The...

Page 5: ...he HDX 4500 systems supplied for evaluation had a maximum call bandwidth of 4 Mbit s and included the 1080p 30fps option The CODEC offers several video resolutions including SIF 352 x 240 pixels CIF 3...

Page 6: ...available are None Preserves the aspect ratio of the source video The image is scaled if necessary to the largest supported resolution that fits on the display without cropping Unused areas of the di...

Page 7: ...t Call Picture outside Picture POP no content near and far sites side by side This image clearly shows the screen reflections Point to Point Call Picture outside Picture POP no content far site large...

Page 8: ...icture POP with 16x9 Content In dual monitor mode with no Content transmitted or received the main monitor displays the far site image and system menus the second monitor displays the near site camera...

Page 9: ...ing effect around the edge of the presenter image The optional high definition MCU provides four host HDX CODEC plus three remote sites The speed of each connection is dependent on the total number of...

Page 10: ...es For added security this remote management system may be password protected For connection to a room control system etc an RS232 serial control port is also provided D SYSTEM OPERATION The remote co...

Page 11: ...annel The two signals are then sent to the remote site for simultaneous display on two picture monitors Both channels can deliver high resolution high frame rate images Successful H 239 conferences we...

Page 12: ...shots of the transmitted and received images are also available from the web interface using either Remote Monitoring which provides snapshots of the near and far video images or Web Director which p...

Page 13: ...10 Remote Monitoring Web Director Screenshots reproduced by permission of Polycom...

Page 14: ...SUMMARY Setup The echo canceller is fully automatic in operation The quality of echo cancellation and doubletalk from the system was excellent Audio levels adequate Yes No Yes Audio quality acceptable...

Page 15: ...o n n e c t C L P o H In calls between the HDX4500 and Tandberg Edge 95 low resolution CIF was transmitted by the Tandberg and SIF was transmitted by the HDX4500 In calls between the HDX4500 and Tand...

Page 16: ...ected to the Codian MCU using H 264 Video and G 722 1 audio in both directions It interoperated successfully also negotiating 720p resolution on the H 239 channel Received audio level was measured as...

Page 17: ...Connector Monitor Loudspeakers Internal connection Both RCA Phono Main audio output Line Data 1 1 off LAN 10 100 Mbits s Ethernet connection RJ45 2 1 off 9 pin RS232 serial control 3 1 off USB connec...

Page 18: ...rs CLR Jerkiness distortion of smooth motion JRK Object persistence lagging images from previous frames as faded or outline images OP Scene cut response i e time to build up the new image SCR Scale of...

Page 19: ...emote site Subjective Impairments H 323 384 kbit s 768 kbit s 2 0 Mbit s 4 0 Mbit s BLK 1 1 1 1 BLR 1 1 1 1 CLR 1 1 1 1 Test 3 H 264 Blue screen Insert blue screen at local site measure at remote site...

Page 20: ...ents H 323 384 kbit s 768 kbit s 2 0 Mbit s 4 0 Mbit s BLK 3 1 1 1 BLR 3 2 1 1 CLR 1 1 1 1 JRK 2 1 1 1 Test 9 H 264 Three shot quick zoom in to medium close up centre person Subjective Impairments H 3...

Page 21: ...ubjective Impairments H 323 384 kbit s 768 kbit s 2 0 Mbit s 4 0 Mbit s BLK 4 3 2 1 BLR 5 4 2 2 CLR 2 2 2 2 JRK 2 1 1 1 Test 12 H 264 Zoom in and zoom out of A to Z map Subjective Impairments H 323 38...

Page 22: ...LR 1 1 1 1 OP 1 1 1 1 SCR 3 2 2 2 JRK 3 2 2 1 Test 15 H 264 Man teaching with flip chart Subjective Impairments H 323 384 kbit s 768 kbit s 2 0 Mbit s 4 0 Mbit s LS 2 2 1 1 BLK 2 1 1 1 BLR 2 2 1 1 CLR...

Page 23: ...ting a notch in the frequency response between these frequencies Test 2 Headroom measured on Siren 22 64Kbit s connection Insert increasing amplitude 1 KHz tone at local site monitor for overload dist...