Connecting to the 5300LF2 VBP-ST Series for the First Time 

The VBP Series appliance is shipped with a pre-configured IP address on Port 1 of 192.168.1.1 
 

1.  Connect the 3-pin Shroud female plug of the power cord into the input power socket in the system shown as (

H

) in the above figures and 

the other end to a wall AC outlet. 

 

2.  Turn the system power on by pressing on the top part of the power switch shown as (

I

) in the above figures. 

 

3.  Connect a computer using an IP address of 192.168.1.2 and subnet mask of 255.255.255.0 to Port 1 shown as (

D

) in the above figures 

with either a Ethernet switch or a Ethernet cable wired directly to the computer. 

 

4.  Launch a Web browser on the PC and enter the 

http://192.168.1.1

   Press Return.  The main configuration menu appears - enter the 

username root and the password default. 

 

5.  The EULA license agreement will now be displayed. After reading the license agreement, click “I agree” at the bottom to continue 

configuring the system. 

 
Configure the Network parameters as defined in the Configuration Guide contained on the VBP Documentation Library CD provided with the 
system. The Configuration Guide is also available on the Polycom Web site. 

 

Summary of Contents for 5300LF2 VBP-E Series

Page 1: ...Polycom VBP 5300LF2 System Hardware Guide June 2011 3725 73553 001A...

Page 2: ...ctronic or mechanical for any purpose without the express written permission of Polycom Inc Under the law reproducing includes translating into another language or format As between the parties Polyco...

Page 3: ...the same network as the WAN or LAN subnets This network cannot be within a subnet contained in a Route statement C Port 2 WAN interface 1 x 10 100 1000 Mbps Ethernet port for connectivity to the WAN o...

Page 4: ...Guide 3 Symbol Function Color Signal Power Status Green Off No Power the system is off On Power is good the system is on G Data Status Red Off No data access to the IDE drive On Data is being written...

Page 5: ...he network cable check cable replace cable ACK LINK Green or other Flashing The adapter is sending and receiving network data The frequency of the flashing varies with the amount of data being transfe...

Page 6: ...5300LF2 Hardware Guide 5 H Input Power Socket Accepts 3 pin Shroud Female plug for input power I On Off Switch Used to turn the system on and off J VGA Currently not used...

Page 7: ...f 192 168 1 2 and subnet mask of 255 255 255 0 to Port 1 shown as D in the above figures with either a Ethernet switch or a Ethernet cable wired directly to the computer 4 Launch a Web browser on the...

Page 8: ...twork as the WAN or LAN subnets This network cannot be within a subnet contained in a Route statement C Port 2 Provider interface 1 x 10 100 1000 Mbps Ethernet port for connectivity to the Provider or...

Page 9: ...Guide 8 Symbol Function Color Signal Power Status Green Off No Power the system is off On Power is good the system is on G Data Status Red Off No data access to the IDE drive On Data is being written...

Page 10: ...he network cable check cable replace cable ACK LINK Green or other Flashing The adapter is sending and receiving network data The frequency of the flashing varies with the amount of data being transfe...

Page 11: ...5300LF2 Hardware Guide 10 H Input Power Socket Accepts 3 pin Shroud Female plug for input power I On Off Switch Used to turn the system on and off J VGA Currently not used...

Page 12: ...ss of 192 168 1 2 and subnet mask of 255 255 255 0 to Port 1 shown as D in the above figures with either a Ethernet switch or a Ethernet cable wired directly to the computer 4 Launch a Web browser on...

Page 13: ...electing 50 to 60 Hz with 200W output BTU h 682 Warranty 1 Year Environmental Requirement Operating Temperature 0 to 40 C Relative Humidity 10 to 90 Acoustics 55db Shock 0 5 Sine shock 10G peak 10 3ms...

Page 14: ...nt the completed assembly into your 19 equipment rack Connecting the Power and Cables The 5300LF2 comes with an AC power cord for connecting the unit to the AC outlet Warning Always connect the AC pow...

Page 15: ...expressly approved by Polycom Inc could void the user s authority to operate this equipment The socket outlet to which this apparatus is connected must be installed near the equipment and must always...

Page 16: ...a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices does not exceed 5 The REN of...

Page 17: ...5300LF2 Hardware Guide 16 Korea China...

Page 18: ...l rer herved at f lgende udstyr VBP 5300LF2 overholder de v sentlige krav og vrige relevante krav i direktiv 1999 5 EF Deutsch German Hiermit erkl rt Polycom dass sich das Ger t VBP 5300LF2 in bereins...

Page 19: ...andere relevante bepalingen van richtlijn 1999 5 EG Malti Maltese Hawnhekk Polycom jiddikjara li dan VBP 5300LF2 jikkonforma mal ti ijiet essenzjali u ma provvedimenti o rajn relevanti li hemm fid Di...

Page 20: ...r if properly used in accordance with procedures described in the documentation supplied by Polycom End user shall notify Polycom of any nonconformance during the warranty period obtain a return autho...

Page 21: ...Electrical Equipment WEEE Directive all Polycom products are marked with the crossed wheelie bin symbol shown below Products that carry this symbol should be not be disposed of in the household or gen...

Reviews: