ME-400 Installation Instructions

10

1. After reading precaution, decide where you are going to install the unit. Also, see 

installation diagram.

2. Once the location has been determined, place the amplifier into position. Using a 

felt tip pen or pencil mark the four holes to be drilled for mounting. NEVER use the 
amplifier as a template for drilling. It is very easy to damage the amplifier surface in 

this manner. 

3. Remove amplifier. Drill four 3.5mm holes into mounting surface. If you want to mount 

the amplifier to MDF or wood panel, drill four 3mm diameter holes into mounting 

surface.

4. If possible, test the system to ensure it is operating correctly before final mounting 

of the amplifier.

5. Mount the amplifier using the supplied 4 self threading screws.

Mounting

Each channel pair has a set of controls. Channels 1 and 2 adjust together; channels 3 

and 4 adjust together.

1. Set to the “HP” (High Pass) position when the amplifier is used to drive a tweeter/

midrange system. The frequencies below the crossover point will be attenuated at 

12dB/octave. Permits adjustment of the crossover frequency, by rotating the knob 
to select any frequency between 40Hz to 250Hz as the crossover point.

2. Set to the “LP” (Low Pass) position when the amplifier is used to drive a subwoofer. 

The frequencies above the crossover point will be attenuated at 12dB.octave. 
Permits adjustment of the crossover frequency, by rotating the knob to select any 
frequency between 40Hz to 250Hz as the crossover point.

3. Set to the “FULL” position when the amplifier will be used for driving full-range 

speaker. The full frequency bandwidth ( 10Hz ~ 35KHz ) will be output to the speak

-

ers without high or low frequency attenuation.

4. Level adjustment – The sensitivity adjustment is to allow the amplifier to work with 

many different sources. It allows the input signal to vary between 200 millivolts to 6 

volts from the head unit or other signal processor. 

5. The “Bass Boost” function can be selected to increase low frequency output. This is 

adjustable up to +18dB boost at 45Hz.

ME-400 Specifications

RATED POWER @4ohm , THD 1%

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

100W x 4CH

RATED POWER @2ohm , THD 1%

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

150W x 4CH

RATED POWER @4ohm Bridged, THD 1%

 . . . . . . . . . . . . . . . . . . . . . . . . . . . .

300W x 2CH

MAXIMUM OUTPUT POWER

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

800W

T.H.D @4ohm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

0.05%

T.H.D @2ohm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 

0.08%

T.H.D @4ohm Bridged

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0.1%

FREQUENCY RESPONSE @-1dB 

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10Hz ~ 35KHz

SIGNAL TO NOISE RATIO @ A weighted

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . >90dB

INPUT SENSITIVITY

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

200mV ~ 6.0V

INPUT IMPEDANCE

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20Kohm

LOW PASS FILTER

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Variable 40Hz ~ 250Hz

HIGH PASS FILTER

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Variable 40Hz ~ 250Hz

BASS BOOST @45Hz

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

0 ~ 18 dB

FUSE RATING

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

20A x 2

DIMENSION ( W x H x D )

 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

415mm x 55mm x 240mm

 

16.33” x 2.17” x 9.45” 

NOTE : Specification & design subject to change without notice for improvements.

ME-400 Adjustments

3

Summary of Contents for ME-400

Page 1: ...ts Variable input level controls for each pair of channels Variable High pass Low pass and All pass crossover Variable Bass Boost circuit Thermal and overload protection circuitry Gold plated RCA jacks and terminals Rubber isolation mounting feet ME 400 Features PLEASE READ THIS MANUAL BEFORE INSTALLATION AND USING AMPLIFIER Poly Planar products are warranted to be free of defects in materials and...

Page 2: ...lower NEVER operate the amplifier without proper power and ground wire of at least 10 gauge or lower NEVER operate the amplifier without proper fusing Fuse holder must be located with in 0 5 meters from the battery This fuse is to protect the vessel not the electronics In case of a short the fuse will blow instead of the wire burning up Using other than the recommended fuse ratings at the battery ...

Page 3: ...frequency between 40Hz to 250Hz as the crossover point 2 Set to the LP Low Pass position when the amplifier is used to drive a subwoofer The frequencies above the crossover point will be attenuated at 12dB octave Permits adjustment of the crossover frequency by rotating the knob to select any frequency between 40Hz to 250Hz as the crossover point 3 Set to the FULL position when the amplifier will ...

Page 4: ...ns Remember to complete an electrical circuit the ground connection is just as important as the positive power connection Before any power connections are made disconnect the ground cable at the battery When the power supply lead memory backup lead or ground lead are extended use a 5mm 2 AWG5 or larger automotive grade cable which will withstand friction and heat to safe grade against fires occurr...

Page 5: ...l input on the amplifier Input Connections 1 Line in RCA Jacks These inputs are for line level signals from the source Always use high quality cables and DO NOT run them along side the power or speaker wires 2 Input Level Controls Two controls for adjusting the volume of each pair of channels Channels 1 2 adjust together channels 3 4 adjust together 3 Crossover Mode Switch High Pass HP lets freque...

Page 6: ...ohms per channel The minimum impedance for bridged operation is 4 ohms Connect right and left speaker wire to corresponding speaker output terminals of the amplifier Be sure to have the positive wire from the speaker connected to the positive speaker terminal of the amplifier Reversing any of these connections will result in the speaker cones moving out of phase which causes bass cancellation See ...

Reviews: