Poly-Control Danalock V3 Quick Start Manual Download Page 1

Poly-Control

Danalock V3

SKU: POLELOCKV3

 

 

 

Quickstart

This is a 

secure Door Lock 

for 

Europe

. To run this device please insert fresh 

4 * CR123A

 batteries. Please make sure the internal battery is fully

charged. To add this device to your network execute the following action: 

 

Push the switch once.

 

Create PDF in your applications with the Pdfcrowd 

HTML to PDF API

PDFCROWD

Summary of Contents for Danalock V3

Page 1: ...Europe To run this device please insert fresh 4 CR123A batteries Please make sure the internal battery is fully charged To add this device to your network execute the following action Push the switch...

Page 2: ...ther certified Z Wave device regardless of brand and origin as long as both are suited for the same frequency range If a device supports secure communication it will communicate with other devices sec...

Page 3: ...cylinder Power supply 4x CR123 Battery lifetime 6 12 month torque 1 5 Nm Prepare for Installation Reset Please read the user manual before installing the product In order to include add a Z Wave devi...

Page 4: ...move the batteries when the device is not used Do not mix batteries of different charging level or different brands Installation 1 Remove the old cylinder First you have to remove your current cylinde...

Page 5: ...Measure the back part on the outside of your door of the old cylinder from the middle of the screwhole and away see illustration In the Danalock box you ll nd an adjustable lock cylinder If the old cy...

Page 6: ...t the same size of spacer piece and brass tube to make the adjustable cylinder match the old cylinder Please look at the following size guide to find the right length for the spacer piece and the bras...

Page 7: ...Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD...

Page 8: ...have to exchange the brass tube in the center with another that fits the spacer piece Here are the different combinations 6 Assemble the cylinder and screw the small screws back in on both sides of t...

Page 9: ...hand 8 The right rosette spacer To avoid pulling the cylinder out of place you need to find the right spacer or a spacer combination between the rosette and the back plate Unscrew the two breakable s...

Page 10: ...h Depending on which spacer or spacer combination you chose it is now important that the screws that fasten the cylinder to the back plate have the right length Use this chart to find the right length...

Page 11: ...10 Fasten the back plate to the cylinder Now fasten the back plate to the cylinder with the rosette spacer in between them Create PDF in your applications with the Pdfcrowd HTML to PDF API PDFCROWD...

Page 12: ...lock this way please loosenthe cylinder screws 11 Give the tailpiece the right length To avoid damaging the Danalock you will have to shorten the new cylindertailpiece to max 35mm from the door surfac...

Page 13: ...ck Press on the adaptor until a click ensures it is fixed firmly to the Danalock 13 Fit the tailpiece to the middle of the housing base Fit the Danalock over the back plate Make sure the tailpiece hit...

Page 14: ...it Now you are sure to hit the notches on the back plate with the Danalock 15 Fasten the Danalock Turn the Danalock clockwise until it clicks to fasten it to the back plate NOTE If you need to unfast...

Page 15: ...the Danalock from your door insert a pen tip into the hole at the top inner edge of the lock and press while turning the lock counter clockwise until the lock releases This will not reset the lock or...

Page 16: ...usion Devices can also be removed from a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller is turned into exclusion...

Page 17: ...once Product Usage LED signals LEDs are installed at the edge of the Danalock which are protected by LEDs Different colors indicate certain operations Create PDF in your applications with the Pdfcrowd...

Page 18: ...part of the screen page of the Danalock the following commands are triggered Do not allow more than 5 seconds to pass until next time otherwise the entry will be lost and the corresponding command is...

Page 19: ...both devices use the same frequency 3 Remove all dead devices from associations Otherwise you will see severe delays 4 Never use sleeping battery devices without a central controller 5 Dont poll FLIRS...

Page 20: ...r to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Parameter...

Page 21: ...fault Value 0 Setting Description 0 BLE Always disabled 1 BLE Always enabled Parameter 6 Autolock Lock after an unlock The value is the delay in time before the lock is locked again Size 4 Byte Defaul...

Page 22: ...ID ZC10 17095764 Z Wave Product Id 0x010E 0x0009 0x0001 Firmware Updatable Updatable by Consumer by RF Supported Notification Types Access Control Supported Command Classes Association Grp Info Assoc...

Page 23: ...ding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device W...

Reviews: