HOW TO USE THIS APPLIANCE
•
Before starting the treatment, clean - if necessary - the surfaces and fabrics with the most appropriate method
for removing dirt and dust.
•
If your appliance is equipped with steam adjustment - as it can also be used as a steam cleaner
- set it to an average level or, in the presence of preset programs, refer to the instruction manual.
•
Heating the dispenser: when the appliance is first switched on, dispense “unusable” steam for about 30 seconds
downwards to reach the optimum operating temperature and pressure.
After each pause before treating surfaces or fabrics, dispense for a few seconds in the same way.
WARNING! THIS PROTOCOL DOES NOT REPLACE THE INSTRUCTIONS
AND WARNINGS CONTAINED IN THE USER MANUAL AND ON
THE APPLIANCE: PLEASE READ THEM BEFORE USE.
FREQUENT SANITISING ACTION
Dispense steam with slow and
repeated strokes on the surface at about
10 centimetres per second.
STATIC STEAM DISINFECTION
Deliver steam, perpendicular to
the surface, maintaining a
maximum
distance of 10 centimetres
(stand spacer)
for 30 consecutive seconds.
The steam will be able to treat an area with
a diameter of approximately 10 cm.
CHOOSE THE OPERATION YOU WANT TO DO:
DYNAMIC STEAM DISINFECTION
Compliance with the
AFNOR NF T72-110 STANDARD
1
Deliver steam, perpendicular to
the surface, maintaining a
distance of
0.5 centimetres.
Make at least one pass at
a speed of
10 centimetres per second.
DDV - STEAM DISINFECTION DEVICE
COMPLIES WITH AFNOR NF T72-110 STANDARD
1
PROTOCOL FOR USE