background image

HOW TO USE THIS APPLIANCE

 Before starting the treatment, clean - if necessary - the surfaces and fabrics with the most appropriate method

  for removing dirt and dust.

 If your appliance is equipped with steam adjustment - as it can also be used as a steam cleaner

  - set it to an average level or, in the presence of preset programs, refer to the instruction manual.

 Heating the dispenser: when the appliance is first switched on, dispense “unusable” steam for about 30 seconds  

  downwards to reach the optimum operating temperature and pressure.
  After each pause before treating surfaces or fabrics, dispense for a few seconds in the same way.

WARNING! THIS PROTOCOL DOES NOT REPLACE THE INSTRUCTIONS
AND WARNINGS CONTAINED IN THE USER MANUAL AND ON
THE APPLIANCE: PLEASE READ THEM BEFORE USE.

FREQUENT SANITISING ACTION

Dispense steam with slow and

repeated strokes on the surface at about 

10 centimetres per second.

  

STATIC STEAM DISINFECTION  

Deliver steam, perpendicular to

the surface, maintaining a 

maximum

distance of 10 centimetres

 (stand spacer) 

for 30 consecutive seconds.

The steam will be able to treat an area with 

a diameter of approximately 10 cm.

 

CHOOSE THE OPERATION YOU WANT TO DO:

DYNAMIC STEAM DISINFECTION

 

Compliance with the

AFNOR NF T72-110 STANDARD

1

Deliver steam, perpendicular to

the surface, maintaining a 

distance of

0.5 centimetres.

 Make at least one pass at 

a speed of 

10 centimetres per second.

 

DDV - STEAM DISINFECTION DEVICE

COMPLIES WITH AFNOR NF T72-110 STANDARD

1

PROTOCOL FOR USE

Reviews: