6
IMPORTANT NOTICE
Polivac would like to direct your attention to the following issues so that correct and safe operation of your
gas-powered floor buffer is achieved. The superior performance of gas buffers has led to an increased
demand for the use of this type of floor maintenance equipment. This highlights the need for responsible
manufacturers, owners and operators to stress the importance of safety. These maintenance points are a
guideline to the upkeep of your machine. A more stringent program may be required depending on the type
and amount of use that your machine will be subject to.
DO’S
•
DO
check oil level before starting. It is important that the oil is maintained at the correct level for proper
lubrication and cooling of the engine. Consult the motor manufacturers manual for correct capacity
and oil specifications.
•
DO
check fuel level and hose connection before starting. The entire unit should be visually checked
for any loose or damaged hoses, fittings and connections.
•
DO
keep the debris filter clean (foam filter on top of motor) and free of any dust or lint. Any obstructions
to the cooling system can cause excessive heating and premature failure of the engine.
•
DO
change the oil at least every month / 140 Hours. One of the primary functions of the oil is to cool
the motor. When the oil is dirty or not kept to adequate levels it cannot cool the motor efficiently and
can cause premature failure resulting in costly repairs and down time.
•
DO
check belt tension before starting. Incorrectly adjusted belts will cause slipping and premature
wear. The belt should have approximately movement when depressed.
•
DO
carry out routine maintenance as specified. This will prevent any unnecessary down time of your
machine.
•
DO
run the machine at full throttle. Running the machine at a lower speed will cut down the incoming
fresh air that is required for the cooling of the engine.
DON”TS
•
DO NOT
overfill the gas bottle. Overfilling will cause severe damage to the motor and the gas
regulator.
•
DO NOT
tip the machine over on its left-hand side. If it is tipped on this side the oil in the motor will
run through the carburettor. This will cause the inability of the unit to start or excessive smoking if it
does start.
•
DO NOT
use starting fluid to assist with hard to start engines. Starting fluids can leave a hot spot on
the piston, which will cause premature failure of the engine.
•
DO NOT
apply unnecessary pressure up or down on the stripping machine handle. Machine should
float easily across the floor.
•
DO NOT
over fill oil. Refer to the motor manufacturers manual for specifications and capacity.
•
DO NOT
spray buff. The Polivac buffer is designed as a dry buffer only.
•
DO NOT
buff any floor that has not been properly swept. Loose debris on the floor can become
hazardous flying missiles.
•
DO NOT
modify the unit in any way without the written permission of the Polivac International Pty.
Ltd. Any unauthorised modifications will void the warranty and Polivac International Pty. Ltd. Will not
be responsible for any damages to the unit or caused by the unit.
•
DO NOT
replace the brushes or make any adjustment whilst the motor is running or the gas is turned
on.