Connection to the Emergency supplier:
Within each column is provided space to house a rechargeable Lead 12 V - 1.9
Ah. The internal battery is normally recharged from food through a current
limiter.
NB:
The casings of the battery used, shall have a flammability class HB
or better (UL 94)
•
Connection to the central
Connections to the central processing must be made through shielded
cables.
•
C / o contact Alarm
:
The outputs of the devices consist of relay contacts normally closed for
reporting states and tampering alarm.
The contact output to alarm consists of a static relay with a range from 12V
1A.
Tamper output contact is given by the microswitch, with scope 100mA max.
The outputs are enabled for the following reasons:
Alarm Output
1. Intruder alarm on Rx
2. Alarm Channel on Rx
Tamper Output
1. Opening the cap of barriers
NB
The High Risk Protection is essential that the detectors are tested
with adequate intervals to Test Operational. In this way the control unit
will be able to detect attempts to circumvent.