DIAGNOSTIC DISPLAY CODE DEFINITIONS
Open Load:
There is a break in the wires that lead to the item listed in the chart
(injector, fuel pump, etc.), or the item has failed.
Short-to-Ground:
The wire is shorted to ground between the electronic control
unit and the item listed in the chart.
Shorted Load:
The wires leading to the item listed in the chart are shorted
together, or the item has shorted internally.
Short-to-Battery:
The wire leading from the item listed in the chart to the
electronic control unit is shorted to a wire at battery voltage.
DIAGNOSTIC CODES
COMPONENT
CONDITION
SPN
FMI
Throttle Position
Sensor
Voltage Too High
51
3
Voltage Too Low
51
4
Engine Temperature
Sensor
Voltage Too High
110
3
Voltage Too Low
110
4
Temperature Too High
110
16
Engine Overheat
Shutdown
110
0
Intake Air
Temperature Sensor
Voltage Too High
105
3
Voltage Too Low
105
4
Manifold Absolute
Pressure Sensor
Voltage Too High
102
3
Voltage Too Low
102
4
Signal Out of Range
102
2
Crankshaft Position
Sensor
Circuit Fault
636
8
Plausibility Fault
636
2
Vehicle Speed Signal
Speed Too High
84
8
Plausibility Fault
84
2
Gear Sensor Signal
Voltage Too Low
523
4
Voltage Too High
523
3
Signal Fault
523
2
161
Summary of Contents for Sportsman XP 1000 S 2022
Page 3: ...2022 Owner s Manual Sportsman XP 1000 S...
Page 6: ...4 WELCOME...
Page 8: ...6...
Page 14: ...12...
Page 88: ...86...
Page 100: ...98...
Page 106: ...104 MAINTENANCE...
Page 152: ...150...
Page 156: ...154...
Page 168: ...166...
Page 178: ...DATE MILES KM OR HOURS TECHNICIAN SERVICE PERFORMED COMMENTS 176 MAINTENANCE LOG...
Page 183: ......